SCALANCE X-100 unmanagedOrder number | 6GK5104-2BB00-2AA3 | 6GK5106-1BB00-2AA3 | 6GK5108-0BA00-2AA3 | 6GK5108-0PA00-2AA3 |
|---|
Product type designation | SCALANCE X104-2 | SCALANCE X106-1 | SCALANCE X108 | SCALANCE X108PoE |
|---|
Transmission rate | | | | | Transfer rate | 10 Mbit/s, 100 Mbit/s | 10 Mbit/s, 100 Mbit/s | 10 Mbit/s, 100 Mbit/s | 10 Mbit/s, 100 Mbit/s | Interfaces for communication integrated | | | | | Number of electrical connections | | | | | | 4; RJ45 with securing collar | 6; RJ45 with securing collar | 8; RJ45 with securing collar | 6; RJ45 with securing collar | | | | | 2 | Number of 100 Mbit/s ST(BFOC) ports | | | | | | 2 | 1 | | | Number of 100 Mbit/s SC ports | | | | | | 0 | 0 | 0 | 0 | Number of 1000 Mbit/s LC ports | | | | | | 0 | 0 | 0 | 0 | | 0 | 0 | 0 | 0 | Interfaces others | | | | | Number of electrical connections | | | | | | 1 | 1 | 1 | 1 | | 1 | 1 | 1 | 1 | | 1 | 1 | 1 | 1 | Type of electrical connection | | | | | | 2-pole terminal block | 2-pole terminal block | 2-pole terminal block | 2-pole terminal block | | 4-pole terminal block | 4-pole terminal block | 4-pole terminal block | 4-pole terminal block | Signal-Inputs/outputs | | | | | Operating voltage of the signaling contacts | | | | | | 24 V | 24 V | 24 V | 24 V | Operating current of the signaling contacts | | | | | | 0.1 A | 0.1 A | 0.1 A | 0.1 A | Supply voltage, current consumption, power loss | | | | | Type of voltage of the supply voltage | DC | DC | DC | DC | Supply voltage | | | | | | 24 V | 24 V | 24 V | 24 V | | 18 ... 32 V | 18 ... 32 V | 18 ... 32 V | 18 ... 32 V | Product component fusing at power supply input | Yes | Yes | Yes | Yes | Fuse protection type at input for supply voltage | 0.6 A / 60 V | 0.6 A / 60 V | 0.6 A / 60 V | 4 A / 125 V | Consumed current maximum | 0.16 A | 0.15 A | 0.14 A | 1.7 A | Power loss [W] | | | | | | 3.8 W | 3.6 W | 3.36 W | 10 W | Supplied active power of PSE with PoE | | | | | | | | | 15.4 W | | | | | 30.8 W | Permitted ambient conditions | | | | | Ambient temperature | | | | | | -10 ... +60 °C | -10 ... +60 °C | -20 ... +70 °C | -20 ... +60 °C | | -40 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | | -40 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | | | | | At 55° C ambient temperature on both sides 40 mm distance to adjacent devices | Relative humidity | | | | | | 95 % | 95 % | 95 % | 95 % | Protection class IP | IP30 | IP30 | IP30 | IP30 | Design, dimensions and weight | | | | | Design | compact | compact | compact | compact | Width | 60 mm | 60 mm | 60 mm | 60 mm | Height | 125 mm | 125 mm | 125 mm | 125 mm | Depth | 124 mm | 124 mm | 124 mm | 124 mm | Net weight | 0.78 kg | 0.78 kg | 0.78 kg | 0.9 kg | Product feature conformal coating | | | | No | Mounting type | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | Product functions management, configuration | | | | | Product function | | | | | | No | No | No | No | | Yes | Yes | Yes | Yes | | No | No | No | No | Product functions Redundancy | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | No | No | No | No | Standards, specifications, approvals | | | | | Standard | | | | | | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4A, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | | EN 61000-6-4 (Class A) | EN 61000-6-4 (Class A) | EN 61000-6-4 (Class A) | EN 61000-6-4:2001 | | EN 61000-6-2 | EN 61000-6-2 | EN 61000-6-2 | EN 61000-6-2:2001 | Certificate of suitability CE marking | Yes | Yes | Yes | Yes | Certificate of suitability | EN 61000-6-2, EN 61000-6-4 | EN 61000-6-2, EN 61000-6-4 | EN 61000-6-2, EN 61000-6-4 | EN 61000-6-2:2001, EN 61000-6-4:2001 | | Yes | Yes | Yes | Yes | | | | Yes | No | | | | Yes | No | | | | No | Yes | | Yes | Yes | Yes | Yes | Marine classification association | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | No | | Yes | Yes | Yes | No | product conformity | | | | | | | | | Yes | MTBF at 40 °C | 134.87 y | 136.65 y | 139.83 y | 61.64 y |
Order number | 6GK5112-2BB00-2AA3 | 6GK5116-0BA00-2AA3 | 6GK5124-0BA00-2AA3 |
|---|
Product type designation | SCALANCE X112-2 | SCALANCE X116 | SCALANCE X124 |
|---|
Transmission rate | | | | Transfer rate | 10 Mbit/s, 100 Mbit/s | 10 Mbit/s, 100 Mbit/s | 10 Mbit/s, 100 Mbit/s | Interfaces for communication integrated | | | | Number of electrical connections | | | | | 12; RJ45 with securing collar | 16; RJ45 with securing collar | 24; RJ45 with securing collar | Number of 100 Mbit/s ST(BFOC) ports | | | | | 2 | | | Number of 100 Mbit/s SC ports | | | | | 0 | 0 | 0 | Number of 1000 Mbit/s LC ports | | | | | 0 | 0 | 0 | | 0 | 0 | 0 | Interfaces others | | | | Number of electrical connections | | | | | 1 | 1 | 1 | | 1 | 1 | 1 | | 1 | 1 | 1 | Type of electrical connection | | | | | 2-pole terminal block | 2-pole terminal block | 2-pole terminal block | | 4-pole terminal block | 4-pole terminal block | 4-pole terminal block | Signal-Inputs/outputs | | | | Operating voltage of the signaling contacts | | | | | 24 V | 24 V | 24 V | Operating current of the signaling contacts | | | | | 0.1 A | 0.1 A | 0.1 A | Supply voltage, current consumption, power loss | | | | Type of voltage of the supply voltage | DC | DC | DC | Supply voltage | | | | | 24 V | 24 V | 24 V | | 18 ... 32 V | 18 ... 32 V | 18 ... 32 V | Product component fusing at power supply input | No | No | No | Consumed current maximum | 0.45 A | 0.3 A | 0.45 A | Power loss [W] | | | | | 5.16 W | 4.4 W | 4.8 W | Permitted ambient conditions | | | | Ambient temperature | | | | | -10 ... +70 °C | -20 ... +70 °C | -20 ... +70 °C | | -40 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | | -40 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | Relative humidity | | | | | 95 % | 95 % | 95 % | Protection class IP | IP30 | IP30 | IP30 | Design, dimensions and weight | | | | Design | compact | compact | compact | Width | 120 mm | 120 mm | 180 mm | Height | 125 mm | 125 mm | 125 mm | Depth | 124 mm | 124 mm | 124 mm | Net weight | 1.1 kg | 1.1 kg | 1.5 kg | Mounting type | | | | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | No | No | No | Product functions management, configuration | | | | Product function | | | | | No | No | No | | Yes | Yes | Yes | | No | No | No | Product functions Redundancy | | | | Product function | | | | | Yes | Yes | Yes | | No | No | No | Standards, specifications, approvals | | | | Standard | | | | | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | | EN 61000-6-4:2001 | EN 61000-6-4:2001 | EN 61000-6-4:2001 | | EN 61000-6-2:2001 | EN 61000-6-2:2001 | EN 61000-6-2:2001 | Certificate of suitability CE marking | Yes | Yes | Yes | Certificate of suitability | EN 61000-6-2:2001, EN 61000-6-4:2001 | EN 61000-6-2:2001, EN 61000-6-4:2001 | EN 61000-6-2:2001, EN 61000-6-4:2001 | | Yes | Yes | Yes | | Yes | Yes | Yes | Marine classification association | | | | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | No | No | No | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | MTBF at 40 °C | 61.3 y | 61.3 y | 49.3 y |
|
|