2-paths sensor fitted with four SONO 3200 transducers |
Error in measurement | |
Error in measurement at reference conditions | V > 0.5 … 10 m/s, < ± 0.5 % of rate (v = flow velocity) |
Max. flow velocity | 10 m/s (32 ft) |
Nominal size | DN 100 … 600 (4” … 24”) |
Media temperature | |
| -10 … +200 °C (14 … 392 °F) |
| -20 … +180 °C (-4 … +356 °F) |
| -10 … +190 °C (14 … 374 °F) |
| -200 °C (-328 °F) or up to 250 °C (482 °F) |
Ambient temperature | |
- Standard and Ex-i version
| -20 … +60 °C (-4 … +140 °F) |
| -20 … +180 °C (-4 … +356 °F) |
Enclosure | IP67 (NEMA 4X/6)/IP68 (NEMA 6P) and ATEX (see below) |
Process connections | |
PN designated EN 1092-1, type 11 (B) | |
Pipe material carbon steel | - DN 200 … DN 600 (8” … 24”), PN 10
|
- DN 100 … DN 600 (4” … 24”), PN 16
|
- DN 200 … DN 600 (8” … 24”), PN 25
|
- DN 100 … DN 500 (4” … 20”), PN 40
|
Class designated EN 1759-1 | |
Pipe material carbon steel | - DN 100 … DN 600 (4” … 24”) Class 150
|
- DN 100 … DN 300 (4” … 12”) Class 300
|
Without flanges (EN 10217), weld-in version only in carbon steel | - DN 350 … DN 600 (14” … 24”), PN 10
|
- DN 100 … DN 600 (4” … 24”), PN 16
|
- DN 200 … DN 600 (8” … 24”), PN 25
|
- DN 100 … DN 500 (4” … 20”), PN 40
|
Transducer SONO 3200 | O-ring or flange versions |
Materials | |
Pipe | Steel EN 1.0345-P235GH |
Flange | |
PN | EN 10025-S235JRG2, 1E1 |
Class | ASTM A105,1,1 |
Transducer body | Stainless steel AISI 316 or similar |
Transducer terminal house | Stainless steel AISI 316 or plastic PA 6.6 |
Certificates and approvals | |
System ATEX approval for SONO 3100 together with transmitter FUS060-Ex | ATEX II 2 G Ex dem [ia/ib] IIC T6/T4/T3 Gb or |
ATEX II 2G Ex d IIC T3-T6 Gb with SONO 3200 Ex d transducers (for standard FUS060 transmitter, installed outside of Ex zone) |
For FUS060 Ex version the transducer cable length is restricted to 3 m (9.84 ft), in order to meet requirements for electrical immunity. |
Conformity certificate | The devices are supplied as standard with a Siemens Certificate of Conformity on DVD. |
Material certificates | Material certificate according to EN 10204-3.1 is optionally available. |
NDT examination report | Extended material certificate is optionally available. |
Pressure certificate | Pressure test according EN 1024-2.3 optionally available |
Calibration report | A standard calibration report is shipped with each flowmeter. |
Optionally available: |
Extended accredited ISO/IEC 17025 calibration certificates |
Approvals | No custody transfer approvals |