Measuring principle | Electromagnetic induction | Electromagnetic induction |
Excitation frequency (Mains supply: 50 Hz/60 Hz) | DN 2 … 65 (1/12“ … 2?”): 12.5 Hz/15 Hz DN 80, 100 (3", 4"): 6.25 Hz/7.5 Hz | DN 15 … 50 (?" … 2"): 12.5 Hz/15 Hz DN 80, 100 (3", 4"): 6.25 Hz/7.5 Hz |
Process connection | | |
Nominal size | | |
| DN 2 … DN 100 (1/12" … 4") | DN 15 … DN 100 (?" … 4") |
| DN 10 … DN 100 (3/8" … 4") | |
Mating flanges | EN 1092-1 (DIN 2501), ANSI B 16.5 class 150 and 300 or equivalent | EN 1092-1 (DIN 2501), ANSI B 16.5 class 150 and 300 or equivalent |
Option: DN 2 … 10 (1/12" … 3/8"): G?"/NPT ?" pipe connection adapters | |
Rated operating conditions | | |
Ambient conditions | | |
Ambient temperature | | |
| -40 … +100 °C (-40 … +212 °F) | -40 … +100 °C (-40 … +212 °F) |
| -20 … +60 °C (-4 … +140 °F) | -20 … +60 °C (-4 … +140 °F) |
- Compact with transmitter MAG 5000/6000
| -20 … +60 °C (-4 … +140 °F) | |
- Compact with transmitter MAG 6000 I
| -20 … +60 °C (-4 … +140 °F) | |
- Compact with transmitter MAG 6000 I Ex
| -20 … +60 °C (-4 … 140 °F) | |
Temperature of medium | | |
| -20 … +150 °C (-4 … +302 °F) | -20 … +200 °C (-4 … +392 °F) |
| -20 … +150 °C (-4 … +302 °F) | -20 … +180 °C (-4 … +356 °F) |
| -30 … +130 °C (-22 … +266 °F) Suitable for steam sterilization at 150 °C (302 °F) | |
Temperature shock | | |
| | |
- Duration ? 1 min, followed by 10 min rest
| - DN 2, 3 (1/12", 1/8") No limitations
| - DN 15, 25: Max. ?T ? 80 °C/min (?", 1": Max. ?T ? 144 °F/min)
|
- DN 6, 10, 15, 25: Max. ?T ? 80 °C/min (?", 3/8", ?", 1": Max. ?T ? 144 °F/min)
| - DN 40, 50: Max. ?T ? 70 °C/min (1?", 2": Max. ?T ? 126 °F/min)
|
- DN 40, 50, 65: Max. ?T ? 70 °C/min (1?”, 2", 2?": Max. ?T ? 126 °F/min)
| - DN 80, 100: Max. ?T ? 60 °C/min (3", 4": Max. ?T ? 108 °F/min)
|
- DN 80, 100: Max. ?T ? 60 °C/min (3", 4": Max. ?T ? 108 °F/min)
| |
| Max. ± 100 °C (212 °F) momentarily | |
Operating pressure | | |
| - DN 2 … 65: 40 bar (1/12" … 2?": 580 psi)
| - DN 15 … 50: 40 bar (?" … 2": 580 psi)
|
- DN 80: 37.5 bar (3": 540 psi)
| - DN 80: 37.5 bar (3": 540 psi)
|
- DN 100: 30 bar (4": 435 psi)
| - DN 100: 30 bar (4": 435 psi)
|
Vacuum: 1 x 10-6 barabs (1.5 x 10-5 psiabs) | Vacuum: 1 x 10-6 barabs (1.5 x 10-5 psiabs) |
| 20 bar (290 psi) | |
Vacuum: 0.02 barabs (0.3 psiabs) | |
DN 80 … DN 100: CO2 pressure max. 7 bar (101.5 psi) | |
Mechanical load (vibration) | - 18 … 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36
| - 18 … 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36
|
| |
- Sensor with compact MAG 5000/6000 mounted transmitter: 3.17 g RMS
| |
- Sensor with compact MAG 6000 I/6000 I Ex mounted transmitter: 1.14 g RMS
| |
- For compact installation with the MAG 6000 I, transmitter to be supported to avoid tension on sensor part.
| |
Enclosure rating (standard) | IP67 to EN 60529 (NEMA 4X), 1 mH2O for 30 min | IP67 to EN 60529 (NEMA 4X), 1 mH2O for 30 min |
EMC | 2014/30/EU | 2014/30/EU |
Design | | |
Weight | See Dimensional drawings | See Dimensional drawings |
Material | | |
| | |
| Stainless steel AISI 316L/1.4404 | Stainless steel AISI 316L/1.4404 |
| | |
| Fibre glass reinforced polyamide (not for Ex) | Stainless steel AISI 316/1.4436 |
| Stainless steel AISI 316/1.4436 | |
| Stainless steel AISI 304/1.4301, Number and size to EN 1092-1:2001 | Stainless steel AISI 304/1.4301, Number and size to EN 1092-1:2001 |
| | |
| EPDM (max. 150 °C, PN 40 (max. 302 °F, 600 psi)) | Graphite (max. 200 °C, PN 40 (max. 392 °F, 600 psi)) |
| - Graphite (max. 200 °C, PN 40 (max. 392 °F, 600 psi))
| |
- PTFE (max. 130 °C, PN 25 (max. 266 °F, 300 psi))
| |
- Pipe connection adapters:
DN 2, 3, 6 and 10 (1/12", 1/8", ?" and 3/8")
| - Stainless steel, AISI 316 /1.4436
| |
| |
| |
Liner | | |
| - DN 2, 3 (1/12", 1/8"): Zirconium oxide (ZrO2) (ceramic)
| DN 15 … 100 (?", 4"): Aluminum oxide Al2O3 |
- DN 6 … 100 (?" … 4"): Aluminum oxide Al2O3
| |
| Reinforced PFA (not for Ex) | |
Electrodes | | |
| - DN 10 … 100 (3/8" … 4"): Platinum with gold/Titanium brazing alloy
| Platinum with gold/Titanium brazing alloy |
- DN 2 … 6 (1/12" … ?"): Platinum
| |
| - DN 10 … 15 (3/8" … ?"): Hastelloy C276/2.4819
| |
- DN 25 … 100 (1" … 4"): Hastelloy C22/2.4602
| |
Cable entries | - Remote installation 2 x M20 or 2 x ?" NPT
| Remote installation 2 x M20 or 2 x ?" NPT |
| |
- MAG 5000/MAG 6000: 4 x M20 or 4 x ?" NPT
| |
- MAG 6000 I: 2 x M25 (for supply/output)
| |
- MAG 6000 I Ex: 2 x M25 (for supply/output)
| |
Certificates and approvals | | |
Calibration | | |
- Standard production calibration
| Zero-point, 2 x 25 %, 2 x 90 % | Zero-point, 2 x 25 %, 2 x 90 % |
| 5-point calibration: 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax 10-point calibration: ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax Matched-pair calibration: default, 5-point or 10-point | |
Hazardous areas | | |
| | |
- Ex-sensor in compact or remote version with MAG 6000 I Ex
| - Zone 1 Ex d e ia IIB T6 Gb
| - Zone 1 Ex d e ia IIB T6 Gb
|
- Standard sensor in compact or remote version with MAG 5000/6000/6000 I
| - NI Class I Div. 2 Groups A, B, C, D
| - NI Class I Div. 2 Groups A, B, C, D
|
| | |
- Standard sensor in compact or remote version with MAG 5000/6000/6000 I
| - NI Class I Div. 2 Groups A, B, C, D
| |
Hygienic | | |
| - 3A (remote version with Polyamide terminal box)
| |
| - 3A (remote version with Polyamide terminal box)
- EHEDG (remote version with Polyamide terminal box, DN 25 ... 100 /1 ... 4")
- Hygienic EC 1935:2004 European food contact material
| |
Pressure equipment | - PED – 2014/68/EU
- CRN (only PFA)
| |
Others | - EAC (Russia, Belarus, Kazakhstan)
- KCC (South Korea)
| - EAC (Russia, Belarus, Kazakhstan)
- KCC (South Korea)
|