SM 331 analog input modules

Article number

6ES7331-7KF02-0AB0

6ES7331-7HF01-0AB0

6ES7331-1KF02-0AB0

6ES7331-7KB02-0AB0

SM331, 8AI, 9/12/14BIT

SIMATIC S7-300, ANALOG INPUT

SM331, 8AI, 13BIT

SM331, 2AI, 9/12/14BIT

Supply voltage

 

 

 

 

Load voltage L+

 

 

 

 

  • ? Rated value (DC)

24 V

24 V

24 V

Input current

 

 

 

 

from load voltage L+ (without load), max.

30 mA

50 mA

30 mA

from backplane bus 5 V DC, max.

50 mA

100 mA

90 mA

50 mA

Power loss

 

 

 

 

Power loss, typ.

1 W

1.5 W

0.4 W

1 W

Analog inputs

 

 

 

 

Number of analog inputs

8

8

8

2

  • ? For resistance measurement

4

8

1

permissible input voltage for voltage input (destruction limit), max.

20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)

20 V; 20 V DC permanent, 75 V DC for max. 1 s (duty factor 1:20)

30 V; 12 V continuous, 30 V for max. 1 s

20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)

permissible input current for current input (destruction limit), max.

40 mA

40 mA

40 mA

40 mA

Input ranges (rated values), voltages

 

 

 

 

  • ? 0 to +10 V

No

No

Yes

No

  • ? 1 V to 5 V

Yes

Yes

Yes

Yes

  • ? 1 V to 10 V

No

No

No

  • ? -1 V to +1 V

Yes

Yes

Yes

Yes

  • ? -10 V to +10 V

Yes

Yes

Yes

Yes

  • ? -2.5 V to +2.5 V

Yes

No

Yes

  • ? -250 mV to +250 mV

Yes

No

Yes

  • ? -5 V to +5 V

Yes

Yes

Yes

Yes

  • ? -50 mV to +50 mV

No

Yes

No

  • ? -500 mV to +500 mV

Yes

Yes

Yes

Yes

  • ? -80 mV to +80 mV

Yes

Yes

No

Yes

Input ranges (rated values), currents

 

 

 

 

  • ? 0 to 20 mA

Yes

Yes

Yes

Yes

  • ? -10 mA to +10 mA

Yes

No

Yes

  • ? -20 mA to +20 mA

Yes

Yes

Yes

Yes

  • ? -3.2 mA to +3.2 mA

Yes

No

Yes

  • ? 4 mA to 20 mA

Yes

Yes

Yes

Yes

Input ranges (rated values), thermocouples

 

 

 

 

  • ? Type B

No

No

No

  • ? Type C

No

No

  • ? Type E

Yes

No

Yes

  • ? Type J

Yes

No

Yes

  • ? Type K

Yes

No

Yes

  • ? Type L

Yes

No

No

  • ? Type N

Yes

No

Yes

  • ? Type R

No

No

No

  • ? Type S

No

No

No

  • ? Type T

No

No

No

  • ? Type U

No

No

No

  • ? Type TXK/TXK(L) to GOST

No

No

No

Input ranges (rated values), resistance thermometer

 

 

 

 

  • ? Cu 10

No

No

No

  • ? Ni 100

Yes; Standard

Yes; Standard/climate

Yes

  • ? Ni 1000

No

Yes

No

  • ? LG-Ni 1000

No

Yes; Standard/climate

No

  • ? Ni 120

No

No

No

  • ? Ni 200

No

No

No

  • ? Ni 500

No

No

No

  • ? Pt 100

Yes; Standard

Yes; Standard/climate

Yes

  • ? Pt 1000

No

No

No

  • ? Pt 200

No

No

No

  • ? Pt 500

No

No

No

Input ranges (rated values), resistors

 

 

 

 

  • ? 0 to 150 ohms

Yes

No

Yes

  • ? 0 to 300 ohms

Yes

No

Yes

  • ? 0 to 600 ohms

Yes

Yes

Yes

  • ? 0 to 6000 ohms

No

Yes

No

Thermocouple (TC)

 

 

 

 

Temperature compensation

 

 

 

 

  • parameterizable

Yes

No

Yes

  • internal temperature compensation

Yes

No

Yes

  • external temperature compensation with compensations socket

Yes

No

Yes

Characteristic linearization

 

 

 

 

  • ? parameterizable

Yes

Yes

Yes

  • for thermocouples

Type E, J, K, L, N

No

Type E, J, K, L, N

  • for resistance thermometer

Pt100 (standard, climatic range), Ni100 (standard, climatic range)

yes; Pt100 standard/air con.; Ni100 standard/air con.; Ni1000 standard/air con.; LG-Ni1000 standard/air con.

Pt100 (standard, climatic range), Ni100 (standard, climatic range)

Cable length

 

 

 

 

  • ? shielded, max.

200 m; 50 m at 80 mV and thermocouples

200 m

200 m; max. 50 m at 50 mV

200 m; 50 m at 80 mV and thermocouples

Analog value generation for the inputs

 

 

 

 

Measurement principle

integrating

Actual value encryption

integrating

integrating

Integration and conversion time/resolution per channel

 

 

 

 

  • ? Resolution with overrange (bit including sign), max.

15 bit; Unipolar: 9/12/12/14 bit; bipolar: 9 bit + sign/12 bit + sign/12 bit + sign/14 bit + sign

14 bit; Unipolar: 14 bit; bipolar: 13 bit + sign

13 bit

15 bit; Unipolar: 9/12/12/14 bit; bipolar: 9 bit + sign/12 bit + sign/12 bit + sign/14 bit + sign

  • ? Integration time, parameterizable

Yes; 2,5 / 16,67 / 20 / 100 ms

Yes

Yes; 60 / 50 ms

Yes; 2,5 / 16,67 / 20 / 100 ms

  • ? Basic conversion time (ms)

3 / 17 / 22 / 102 ms

52 µs per channel

66 / 55 ms

3 / 17 / 22 / 102 ms

  • ? Interference voltage suppression for interference frequency f1 in Hz

400 / 60 / 50 / 10 Hz

none / 400 / 60 / 50 Hz

50 / 60 Hz

400 / 60 / 50 / 10 Hz

Encoder

 

 

 

 

Connection of signal encoders

 

 

 

 

  • ? for current measurement as 2-wire transducer

Yes

Yes

Yes; with external supply

Yes

  • ? for current measurement as 4-wire transducer

Yes

Yes

Yes

Yes

  • ? for resistance measurement with two-wire connection

Yes

Yes

Yes

  • ? for resistance measurement with three-wire connection

Yes

Yes

Yes

  • ? for resistance measurement with four-wire connection

Yes

Yes

Yes

Errors/accuracies

 

 

 

 

Operational error limit in overall temperature range

 

 

 

 

  • ? Voltage, relative to input range, (+/-)

1 %; ±1% (80 mV); ±0.6% (250 mV to 1 000 mV); ±0.8% (2.5 V to 10 V)

0.4 %

0.6 %; +/-0.6% (+/-5 V, 10 V, 1 to 5 V, 0 to 10 V); +/-0.5% (+/-50 mV, 500 mV, 1 V)

1 %; ±1% (80 mV); ±0.6% (250 mV to 1 000 mV); ±0.8% (2.5 V to 10 V)

  • ? Current, relative to input range, (+/-)

0.7 %; From 3.2 to 20 mA

0.3 %

0.5 %; +/-20 mA, 0 to 20 mA, 4 to 20 mA

0.7 %; From 3.2 to 20 mA

  • ? Resistance, relative to input range, (+/-)

0.7 %; 150, 300, 600 Ohm

0.5 %; 0 to 6 kohms, 0 to 600 kohms

0.7 %; 150, 300, 600 Ohm

  • ? Resistance thermometer, relative to input range, (+/-)

0.7 %; +/-0.7% (Pt100/ Ni100); +/-0.8% (Pt100 climate)

1 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic); 1.2 Kelvin (Pt100, Ni100, standard)

0.7 %; +/-0.7% (Pt100/ Ni100); +/-0.8% (Pt100 climate)

Basic error limit (operational limit at 25 °C)

 

 

 

 

  • ? Voltage, relative to input range, (+/-)

0.6 %; ±0.4 % (250 mV to 1 000 mV); ±0.6 % (2.5 mV to 10 mV); ±0.7 % (80 mV)

0.25 %

0.4 %; 0.4% (+/-5 V, 10 V, 1 to 5 V, 0 to 10 V); 0.3% (+/-50 mV, 500 mV, 1 V)

0.6 %; ±0.6% (80 mV, 2.5 V to 10 V); ±0.4% (250 mV to 1 000 mV)

  • ? Current, relative to input range, (+/-)

0.5 %; 3.2 to 20 mA

0.2 %

0.3 %; +/-20 mA, 0 to 20 mA, 4 to 20 mA

0.5 %; 3.2 to 20 mA

  • ? Resistance, relative to input range, (+/-)

0.5 %; 150, 300, 600 Ohm

0.3 %; 0 to 6 kohms, 0 to 600 kohms

0.5 %; 150, 300, 600 Ohm

  • ? Resistance thermometer, relative to input range, (+/-)

0.6 %; ±0.5% (Pt100/ Ni100), ±0.6% (Pt100 climate)

1 Kelvin (Pt100, Ni100, standard); 0.8 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic)

0.6 %; ±0.5% (Pt100/ Ni100), ±0.6% (Pt100 climate)

Interrupts/diagnostics/status information

 

 

 

 

Alarms

 

 

 

 

  • ? Diagnostic alarm

Yes; Parameterizable, channels 0 and 2

Yes; Parameterizable

No

Yes

  • ? Limit value alarm

Yes; Parameterizable

Yes; Parameterizable, channels 0 and 2

No

Yes; Parameterizable, channel 0

Diagnostic messages

 

 

 

 

  • ? Diagnostic information readable

Yes

Yes

No

Yes

Potential separation

 

 

 

 

Potential separation analog inputs

 

 

 

 

  • ? between the channels and backplane bus

Yes

Yes

Yes

Yes

Isolation

 

 

 

 

Isolation tested with

500 V DC

500 V DC

500 V DC

500 V DC

Connection method

 

 

 

 

required front connector

20-pin

20-pin

40-pin

20-pin

Dimensions

 

 

 

 

Width

40 mm

40 mm

40 mm

40 mm

Height

125 mm

125 mm

125 mm

125 mm

Depth

117 mm

117 mm

117 mm

120 mm

Weights

 

 

 

 

Weight, approx.

250 g

230 g

250 g

250 g


Article number

6ES7331-7PF01-0AB0

6ES7331-7PF11-0AB0

6ES7331-7PE10-0AB0

6ES7331-7NF00-0AB0

6ES7331-7NF10-0AB0

SIMATIC S7-300, ANALOG INPUT

SIMATIC S7-300, ANALOG INPUT

SM331, 6AI, 16BIT, THERMOCOUPLE

SIMATIC S7-300, ANALOG INPUT

SIMATIC S7-300, ANALOG INPUT

Supply voltage

 

 

 

 

 

Load voltage L+

 

 

 

 

 

  • ? Rated value (DC)

24 V

24 V

24 V

24 V

Input current

 

 

 

 

 

from load voltage L+ (without load), max.

240 mA

240 mA

150 mA

200 mA

from backplane bus 5 V DC, max.

100 mA

100 mA

100 mA

130 mA

100 mA

Power loss

 

 

 

 

 

Power loss, typ.

4.6 W

3 W

2.2 W

0.6 W

3 W

Analog inputs

 

 

 

 

 

Number of analog inputs

8

8

6

8

8

  • ? For resistance measurement

8

permissible input voltage for voltage input (destruction limit), max.

75 V; 35 V continuous, 75 V for max. 1 s (mark to space ratio 1:20)

75 V; 20 V DC permanent, 75 V DC for max. 1 s (duty factor 1:20)

35 V; 35 V continuous, 75 V for max. 1 s (mark to space ratio 1:20)

50 V; Permanent

75 V; 35 V continuous, 75 V for max. 1 s (mark to space ratio 1:20)

permissible input current for current input (destruction limit), max.

32 mA

40 mA

Input ranges (rated values), voltages

 

 

 

 

 

  • ? 0 to +10 V

No

No

No

No

No

  • ? 1 V to 5 V

No

No

No

Yes

Yes

  • ? 1 V to 10 V

No

No

No

No

No

  • ? -1 V to +1 V

No

No

Yes

No

No

  • ? -10 V to +10 V

No

No

No

Yes

Yes

  • ? -2.5 V to +2.5 V

No

No

No

No

No

  • ? -250 mV to +250 mV

No

No

Yes

No

No

  • ? -5 V to +5 V

No

No

No

Yes

Yes

  • ? -50 mV to +50 mV

No

No

Yes

No

No

  • ? -500 mV to +500 mV

No

No

Yes

No

No

  • ? -80 mV to +80 mV

No

No

Yes

No

No

Input ranges (rated values), currents

 

 

 

 

 

  • ? 0 to 20 mA

No

No

No

Yes

Yes

  • ? -10 mA to +10 mA

No

No

No

No

No

  • ? -20 mA to +20 mA

No

No

No

Yes

Yes

  • ? -3.2 mA to +3.2 mA

No

No

No

No

No

  • ? 4 mA to 20 mA

No

No

No

Yes

Yes

Input ranges (rated values), thermocouples

 

 

 

 

 

  • ? Type B

No

Yes

Yes

No

No

  • ? Type C

No

Yes

Yes

No

No

  • ? Type E

No

Yes

Yes

No

No

  • ? Type J

No

Yes

Yes

No

No

  • ? Type K

No

Yes

Yes

No

No

  • ? Type L

No

Yes

Yes

No

No

  • ? Type N

No

Yes

Yes

No

No

  • ? Type R

No

Yes

Yes

No

No

  • ? Type S

No

Yes

Yes

No

No

  • ? Type T

No

Yes

Yes

No

No

  • ? Type U

No

Yes

Yes

No

No

  • ? Type TXK/TXK(L) to GOST

No

Yes

Yes

No

No

Input ranges (rated values), resistance thermometer

 

 

 

 

 

  • ? Cu 10

Yes

No

No

No

No

  • ? Ni 100

Yes

No

No

No

No

  • ? Ni 1000

Yes

No

No

No

No

  • ? LG-Ni 1000

Yes

No

No

No

No

  • ? Ni 120

Yes

No

No

No

No

  • ? Ni 200

Yes

No

No

No

No

  • ? Ni 500

Yes

No

No

No

No

  • ? Pt 100

Yes

No

No

No

No

  • ? Pt 1000

Yes

No

No

No

No

  • ? Pt 200

Yes

No

No

No

No

  • ? Pt 500

Yes

No

No

No

No

Input ranges (rated values), resistors

 

 

 

 

 

  • ? 0 to 150 ohms

Yes

No

No

No

No

  • ? 0 to 300 ohms

Yes

No

No

No

No

  • ? 0 to 600 ohms

Yes

No

No

No

No

  • ? 0 to 6000 ohms

No

No

No

No

Thermocouple (TC)

 

 

 

 

 

Temperature compensation

 

 

 

 

 

  • parameterizable

Yes

Yes

  • internal temperature compensation

Yes

Yes

  • external temperature compensation with compensations socket

Yes

Yes

  • external temperature compensation with Pt100

Yes

Yes

Characteristic linearization

 

 

 

 

 

  • ? parameterizable

Yes

Yes

Yes

  • for thermocouples

Type B, E, J, K, L, N, R, S. T, U, C

Type B, E, J, K, L, N, R, S. T, U, C, TXK, XK(L)

  • for resistance thermometer

Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10; (standard/climate)

No

Cable length

 

 

 

 

 

  • ? shielded, max.

200 m

100 m

200 m

200 m

200 m

Analog value generation for the inputs

 

 

 

 

 

Measurement principle

integrating

integrating

integrating

integrating

integrating

Integration and conversion time/resolution per channel

 

 

 

 

 

  • ? Resolution with overrange (bit including sign), max.

16 bit; Two's complement

16 bit; Two's complement

16 bit; Two's complement

16 bit; Unipolar: 15/15/15/15 bit; bipolar: 15 bit + sign/15 bit + sign/15 bit + sign/15 bit + sign

16 bit; Unipolar: 15/15/15/15 bit; bipolar: 15 bit + sign/15 bit + sign/15 bit + sign/15 bit + sign

  • ? Integration time, parameterizable

Yes

Yes

Yes

Yes; 10/ 16.67/ 20/ 100 ms

Yes; 23 / 72 / 83 / 95 ms

  • ? Basic conversion time (ms)

up to 4 channels: 10 ms per module, over 5 channels: 190 ms per module, 8 channels: 80 ms

Up to 4 channels: 10 ms per module, 5 channels upwards: 190 ms per module

30 / 50 / 60 / 300 ms

10 ms (4-channel mode); 95/83/72/23 ms (8-channel mode)

  • ? Integration time (ms)

10/ 16.67/ 20/ 100 ms

  • ? Interference voltage suppression for interference frequency f1 in Hz

400 / 60 / 50 Hz

400 / 60 / 50 Hz

10 / 50 / 60 / 400 Hz

400 / 60 / 50 / 10 Hz

400 / 60 / 50 Hz, combinations of 400, 60, 50 Hz

Encoder

 

 

 

 

 

Connection of signal encoders

 

 

 

 

 

  • ? for current measurement as 2-wire transducer

Yes; with external transmitter; possible with separate supply for transmitter

Yes; with external transmitter, current supply; possible with separate supply for transmitter

  • ? for current measurement as 4-wire transducer

Yes

Yes

  • ? for resistance measurement with two-wire connection

Yes; without resistance correction

  • ? for resistance measurement with three-wire connection

Yes

  • ? for resistance measurement with four-wire connection

Yes

Errors/accuracies

 

 

 

 

 

Operational error limit in overall temperature range

 

 

 

 

 

  • ? Voltage, relative to input range, (+/-)

+/- 1 K

Operating error at 0 ... 60 °C: ±0.12% @ ±25 mV, ±0.08% @ ±50 mV, ±0.6% @ ±80 mV, ±0.05% @ ±250 mV, ±0.05% @ 500 mV, ±0.05% @ ±1 V

0.1 %; At Ucm = 0 V or ±0.7 % at Ucm = 50 V

0.1 %

  • ? Current, relative to input range, (+/-)

0.3 %; At Ucm = 0 V or ±0.9 % at Ucm = 50 V

0.1 %

  • ? Resistance, relative to input range, (+/-)

0.1 %

  • ? Resistance thermometer, relative to input range, (+/-)

+/- 1 K

Basic error limit (operational limit at 25 °C)

 

 

 

 

 

  • ? Voltage, relative to input range, (+/-)

See manual for details

0.05 %

0.05 %

  • ? Current, relative to input range, (+/-)

0.05 %

0.05 %

  • ? Resistance, relative to input range, (+/-)

0.05 %

  • ? Resistance thermometer, relative to input range, (+/-)

+/- 0,5 K

Interrupts/diagnostics/status information

 

 

 

 

 

Alarms

 

 

 

 

 

  • ? Diagnostic alarm

Yes; Parameterizable per group

Yes; Parameterizable per group

Yes; channel by channel

Yes; Parameterizable

Yes; Parameterizable

  • ? Limit value alarm

Yes; Parameterizable

Yes; Parameterizable

Yes; Parameterizable

Yes; Parameterizable, channels 0 and 2

Yes; Parameterizable all channels (end of cycle interrupt is also supported across modules)

  • ? Hardware interrupt

Yes; Parameterizable, channels 0 to 7

Yes; Parameterizable, channels 0 to 7

Yes; Parameterizable

Yes; Parameterizable, channels 0 to 7 (on exceeding limit value), at end of cycle

Diagnostic messages

 

 

 

 

 

  • ? Diagnostic information readable

Yes

Yes

Yes

Yes

Yes

Potential separation

 

 

 

 

 

Potential separation analog inputs

 

 

 

 

 

  • ? between the channels and backplane bus

Yes

Yes

Yes

Yes

Yes

Isolation

 

 

 

 

 

Isolation tested with

500 V DC

500 V DC

2500 V DC

500 V DC

500 V AC

Connection method

 

 

 

 

 

required front connector

40-pin

40-pin

40-pin

40-pin

40-pin

Dimensions

 

 

 

 

 

Width

40 mm

40 mm

40 mm

40 mm

40 mm

Height

125 mm

125 mm

125 mm

125 mm

125 mm

Depth

120 mm

120 mm

120 mm

117 mm

117 mm

Weights

 

 

 

 

 

Weight, approx.

272 g

272 g

272 g

272 g

272 g


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2017
Siemens Industry Catalog Drive Technology Automation Technology Automation Systems SIMATIC Industrial Automation Systems Controllers I/O systems SIMATIC ET 200 systems for the cabinet SIMATIC ET 200SP SIMATIC ET 200MP SIMATIC ET 200S SIMATIC ET 200M Interface modules SIPLUS Interface modules I/O modules Digital modules Analog modules SM 331 analog input modules SM 332 analog output modules SM 334 analog input/output modules SIPLUS S7-300 analog modules Analog modules with HART F digital/analog modules Ex digital modules Ex analog modules Function modules Special modules Communication Connection system Power supplies SIMATIC ET 200iSP SIMATIC ET 200 systems without control cabinet IO systems for heating elements PROFIBUS components PROFINET components Network components for PROFIBUS Network transitions SIMATIC control systems Software for SIMATIC Controllers Programming devices Siemens Solution Partner SIMOTION Motion Control System SINUMERIK CNC Automation Systems System Cabling / Control Cabinets Automation software Operator control and monitoring systems SIMATIC HMI Identification systems Industrial Communication Industrial Controls Manufacturing Execution Systems (MES) SIMATIC IT PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supplies Products for specific requirements Energy Building Technologies Low-Voltage Controls and Distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services ... and everything else you need