Siemens
ÑÐÅÄÑÒÂÀ ÏÐÎÌÛØËÅÍÍÎÉ ÀÂÒÎÌÀÒÈÇÀÖÈÈ
îôèöèàëüíûé ïàðòíåð Ñèìåíñ
Êàòàëîã ÑÀ01 2017
àðõèâíûé
(4872) 700-366
skenergo@mail.ru

Glass fiber-optic cables

Order number

6XV1873-2A

6XV1873-2B

6XV1873-2G

Product type designation

FO Standard Cable GP

FO FRNC Cable GP

FO Ground Cable

Suitability for use

Cable for installation indoors and outdoors, UL approval

Halogen-free cable (acc. to IEC 61034-1 / 61034-2 and IEC 60754-1 / IEC 60754-2) for use indoors and outdoors with permanent installation, UL approval

Waterproof cable (lengthwise and sideways) with non-metallic protection against rodents for use outdoors as well as for direct routing underground

Version of the assembled FO cable

For assembly with four BFOC or SC connectors

For assembly with four BFOC or SC connectors

For assembly with four BFOC or SC connectors

Cable designation

AT-W(ZN)YY 2x1 G 50/125

AT-W(ZN)HH 2G 50/125 UV

AT-WQ(ZN)Y(ZN)B2Y 2G 50/125

Optical data

 

 

 

Damping ratio per length

 

 

 

  • ? at 850 nm maximum

2.7 dB/km

2.7 dB/km

2.7 dB/km

  • ? at 1300 nm maximum

0.7 dB/km

0.7 dB/km

0.7 dB/km

Bandwidth length product

 

 

 

  • ? at 850 nm

600 GHz·m

600 GHz·m

600 GHz·m

  • ? at 1300 nm

1 200 GHz·m

1 200 GHz·m

1 200 GHz·m

Mechanical data

 

 

 

Number of fibers per FOC core

1

1

1

Number of FO cores per FOC cable

2

2

2

Version of the FO conductor fiber

Multi-mode gradient fiber 50/125 µm, OM 2

Multi-mode gradient fiber 50/125 µm, OM 2

Multi-mode gradient fiber 50/125 µm, OM 2

Design of the FOC core

Hollow core, filled, diameter 1400 µm

Hollow core, filled, diameter 1400 µm

Hollow core, filled, diameter 1400 µm

Design of the fiber-optic cable

segmentable

segmentable

segmentable

Outer diameter

 

 

 

  • ? of the optical fibers

50 µm

50 µm

50 µm

  • ? of the optical fiber sheath

125 µm

125 µm

125 µm

  • ? of the FOC core sheath

2.9 mm

2.9 mm

2.9 mm

Symmetrical deviation of the outer diameter of the FOC core sheath

0.1 mm

0.1 mm

0.1 mm

Outer diameter of the cable

9.2 mm

10.5 mm

Symmetrical deviation of the outer diameter of the line

0.3 mm

0.5 mm

Width of cable sheath

7.4 mm

Thickness of cable sheath

4.5 mm

Material

 

 

 

  • ? of the fiber-optic cable core

Quartz glass

Quartz glass

Quartz glass

  • ? of the optical fiber sheath

Quartz glass

Quartz glass

Quartz glass

  • ? of the FOC core sheath

PVC

FRNC

PVC

  • ? of the fiber-optic cable sheath

PVC

FRNC

PE

  • ? of the strain relief

Aramid fibers

Aramid fibers

Aramid fibers

Color

 

 

 

  • ? of the FOC core sheath

orange/black

orange/black

orange/black

  • ? of cable sheath

green

green

Black

Bending radius

 

 

 

  • ? with single bend minimum permissible

45 mm

90 mm

105 mm

  • ? with multiple bends minimum permissible

65 mm

135 mm

155 mm

Tensile load

 

 

 

  • ? during installation short-term

1 200 N

1 200 N

2 000 N

  • ? during operation maximum

500 N

500 N

800 N

Short-term shear force per length

600 N/cm

500 N/cm

500 N/cm

Continuous lateral force per length

400 N/cm

300 N/cm

Weight per length

40 kg/km

85 kg/km

90 kg/km

Permitted ambient conditions

 

 

 

Ambient temperature

 

 

 

  • ? during operation

-25 ... +80 °C

-40 ... +85 °C

-40 ... +85 °C

  • ? during storage

-25 ... +80 °C

-40 ... +85 °C

-40 ... +85 °C

  • ? during transport

-25 ... +80 °C

-40 ... +85 °C

-40 ... +85 °C

  • ? during installation

-5 ... +50 °C

-5 ... +50 °C

-5 ... +50 °C

Burning behavior

flame-resistant acc. to IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)

flame-resistant acc. to IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)

flammable

Chemical resistance

 

 

 

  • ? to mineral oil

acc. to IEC 60811-404 with test oil IRM 902 (acc. to ISO 1817), +70 °C, 4 h and +25 °C, 168 h

resistant

  • ? to grease

conditional resistance

conditional resistance

resistant

  • ? to water

conditional resistance

conditional resistance

resistant

Radiological resistance to UV radiation

resistant

resistant

resistant

Product properties, functions, components general

 

 

 

Product feature

 

 

 

  • ? halogen-free

No

Yes

No

  • ? silicon-free

Yes

Yes

Yes

Product component Rodent protection

No

No

Yes

Wire length

 

 

 

  • ? for glass FOC for 100BaseFX for Industrial Ethernet maximum

5 000 m

5 000 m

5 000 m

  • ? for glass FOC for 1000BaseSX for Industrial Ethernet maximum

750 m

750 m

750 m

  • ? for glass FOC for 1000BaseLX for Industrial Ethernet maximum

2 000 m

2 000 m

2 000 m

  • ? for glass FOC with PROFIBUS maximum

3 000 m

3 000 m

3 000 m

Standards, specifications, approvals

 

 

 

Certificate of suitability

  • ? RoHS conformity

Yes

Yes

Yes


Order number

6XV1873-2C

6XV1873-2D

Product type designation

FO Trailing Cable

FO Trailing Cable GP

Suitability for use

Flexible cable for use in cable carriers for high mechanical loading, no UL approval

Flexible cable for use in cable carriers for high mechanical loading, UL approval

Version of the assembled FO cable

For assembly with four BFOC or SC connectors

For assembly with four BFOC or SC connectors

Cable designation

AT-W(ZN)Y(ZN)11Y 2G 50/125

AT-W(ZN)Y(ZN)Y 2G 50/125

Optical data

 

 

Damping ratio per length

 

 

  • ? at 850 nm maximum

2.7 dB/km

2.7 dB/km

  • ? at 1300 nm maximum

0.7 dB/km

0.7 dB/km

Bandwidth length product

 

 

  • ? at 850 nm

600 GHz·m

600 GHz·m

  • ? at 1300 nm

1 200 GHz·m

1 200 GHz·m

Mechanical data

 

 

Number of fibers per FOC core

1

1

Number of FO cores per FOC cable

2

2

Version of the FO conductor fiber

Multi-mode gradient fiber 50/125 µm, OM 2

Multi-mode gradient fiber 50/125 µm, OM 2

Design of the FOC core

Hollow core, filled, diameter 1400 µm

Hollow core, filled, diameter 1400 µm

Design of the fiber-optic cable

segmentable

segmentable

Outer diameter

 

 

  • ? of the optical fibers

50 µm

50 µm

  • ? of the optical fiber sheath

125 µm

125 µm

  • ? of the FOC core sheath

2.9 mm

2.9 mm

Symmetrical deviation of the outer diameter of the FOC core sheath

0.1 mm

0.1 mm

Outer diameter of the cable

10.5 mm

10.5 mm

Symmetrical deviation of the outer diameter of the line

0.5 mm

0.5 mm

Material

 

 

  • ? of the fiber-optic cable core

Quartz glass

Quartz glass

  • ? of the optical fiber sheath

Quartz glass

Quartz glass

  • ? of the FOC core sheath

PVC

PVC

  • ? of the fiber-optic cable sheath

PUR

PVC

  • ? of the strain relief

Aramid fibers

Aramid fibers

Color

 

 

  • ? of the FOC core sheath

orange/black

orange/black

  • ? of cable sheath

green

green

Bending radius

 

 

  • ? with single bend minimum permissible

150 mm

150 mm

  • ? with multiple bends minimum permissible

200 mm

200 mm

Number of bending cycles

5 000 000

3 500 000

Tensile load

 

 

  • ? during installation short-term

2 000 N

2 000 N

  • ? during operation maximum

800 N

800 N

Short-term shear force per length

700 N/cm

700 N/cm

Continuous lateral force per length

400 N/cm

400 N/cm

Weight per length

90 kg/km

90 kg/km

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • ? during operation

-40 ... +80 °C

-25 ... +80 °C

  • ? during storage

-40 ... +80 °C

-25 ... +80 °C

  • ? during transport

-40 ... +80 °C

-25 ... +80 °C

  • ? during installation

-5 ... +50 °C

-5 ... +50 °C

Burning behavior

flammable

flame-resistant acc. to IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)

Chemical resistance

 

 

  • ? to mineral oil

acc. to IEC 60811-404 with test oil IRM 902 (acc. to ISO 1817), +100 °C, 168 h, pull speed 250 mm/min.

  • ? to grease

resistant

conditional resistance

  • ? to water

conditional resistance

conditional resistance

Radiological resistance to UV radiation

resistant

resistant

Product properties, functions, components general

 

 

Product feature

 

 

  • ? halogen-free

No

No

  • ? silicon-free

Yes

Yes

Product component Rodent protection

No

No

Wire length

 

 

  • ? for glass FOC for 100BaseFX for Industrial Ethernet maximum

5 000 m

5 000 m

  • ? for glass FOC for 1000BaseSX for Industrial Ethernet maximum

750 m

750 m

  • ? for glass FOC for 1000BaseLX for Industrial Ethernet maximum

2 000 m

2 000 m

  • ? for glass FOC with PROFIBUS maximum

3 000 m

3 000 m

Standards, specifications, approvals

 

 

Certificate of suitability

  • ? RoHS conformity

Yes

Yes


Order number

6XV1820-5AH10

6XV1820-7AH10

Product type designation

Fiber optic standard cable

INDOOR fiber optic indoor cable

Suitability for use

Cable for installation indoors and outdoors

Non-crush, halogen-free and flame-retardant cable for indoor installation

Version of the assembled FO cable

For assembly with four BFOC connectors

For assembly with four BFOC connectors

Cable designation

AT-V(ZN)YY 2X1 G 62.5/125

I-V(ZN)HH 2x1 G 62.5/125

Optical data

 

 

Damping ratio per length

 

 

  • ? at 850 nm maximum

3.1 dB/km

3.1 dB/km

  • ? at 1300 nm maximum

0.8 dB/km

0.8 dB/km

Bandwidth length product

 

 

  • ? at 850 nm

200 GHz·m

200 GHz·m

  • ? at 1300 nm

600 GHz·m

600 GHz·m

Mechanical data

 

 

Number of fibers per FOC core

1

1

Number of FO cores per FOC cable

2

2

Version of the FO conductor fiber

Multimode graded-index fiber 62.5/125 µm, OM 1

Multimode graded-index fiber 62.5/125 µm, OM 1

Design of the FOC core

Compact core, diameter 900 µm

Solid core, diameter 900 µm

Design of the fiber-optic cable

Segmentable outer conductor

Segmentable inner conductor

Outer diameter

 

 

  • ? of the optical fibers

62.5 µm

62.5 µm

  • ? of the optical fiber sheath

125 µm

125 µm

  • ? of the FOC core sheath

3.5 mm

2.9 mm

Symmetrical deviation of the outer diameter of the FOC core sheath

0.1 mm

Width of cable sheath

9.8 mm

6.8 mm

Thickness of cable sheath

6.3 mm

3.9 mm

Material

 

 

  • ? of the fiber-optic cable core

Quartz glass

Quartz glass

  • ? of the optical fiber sheath

Quartz glass

Quartz glass

  • ? of the FOC core sheath

PVC

FRNC

  • ? of the fiber-optic cable sheath

PVC

FRNC

  • ? of the strain relief

Aramid fibers and glass roving

Aramid fibers

Color

 

 

  • ? of the FOC core sheath

gray

gray

  • ? of cable sheath

Black

orange

Bending radius

 

 

  • ? with single bend minimum permissible

80 mm

30 mm

  • ? with multiple bends minimum permissible

80 mm

50 mm

Tensile load

 

 

  • ? during installation short-term

1 500 N

800 N

  • ? during operation maximum

1 500 N

200 N

Short-term shear force per length

300 N/cm

Continuous lateral force per length

200 N/cm

100 N/cm

Weight per length

70 kg/km

30 kg/km

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • ? during operation

-40 ... +85 °C

-20 ... +60 °C

  • ? during storage

-40 ... +85 °C

-25 ... +70 °C

  • ? during transport

-40 ... +85 °C

-25 ... +70 °C

  • ? during installation

-5 ... +50 °C

-5 ... +50 °C

Burning behavior

flame-resistant acc. to IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)

flame-resistant acc. to IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)

Chemical resistance

 

 

  • ? to mineral oil

not resistant

acc. to IEC 60811-404 with test oil IRM 902 (acc. to ISO 1817), +70 °C, 4 h and +25 °C, 168 h

  • ? to grease

not resistant

not resistant

  • ? to water

conditional resistance

conditional resistance

Radiological resistance to UV radiation

resistant

not resistant

Product properties, functions, components general

 

 

Product feature

 

 

  • ? halogen-free

No

Yes

  • ? silicon-free

Yes

Yes

Product component Rodent protection

No

No

Wire length

 

 

  • ? for glass FOC for 100BaseFX for Industrial Ethernet maximum

4 000 m

4 000 m

  • ? for glass FOC for 1000BaseSX for Industrial Ethernet maximum

350 m

350 m

  • ? for glass FOC for 1000BaseLX for Industrial Ethernet maximum

550 m

550 m

  • ? for glass FOC with PROFIBUS maximum

3 000 m

3 000 m

Standards, specifications, approvals

 

 

Certificate of suitability

  • ? RoHS conformity

Yes

Yes


Order number

6XV1820-6AH10

6XV1830-0NH10

Product type designation

Flexible fiber optic trailing cable

SIENOPYR marine duplex fiber-optic cable

Suitability for use

Flexible cable for installation in cable carriers indoors and outdoors

Fixed routing on ships and on offshore platforms in all enclosed spaces and on open deck, marine approval available

Version of the assembled FO cable

For assembly with four BFOC connectors

For assembly with four multimode FO connectors (e.g. BFOC, SC, ...)

Cable designation

AT-W11Y(ZN)11Y 2 G 62.5/125

MI-VHH 2G 62.5/125 3.1B200 + 0.8F600 + 2x1Cu 300V

Optical data

 

 

Damping ratio per length

 

 

  • ? at 650 nm maximum

160 dB/km

  • ? at 850 nm maximum

3.1 dB/km

3.1 dB/km

  • ? at 1300 nm maximum

0.8 dB/km

0.8 dB/km

Bandwidth length product

 

 

  • ? at 850 nm

200 GHz·m

200 GHz·m

  • ? at 1300 nm

600 GHz·m

600 GHz·m

Mechanical data

 

 

Number of fibers per FOC core

1

1

Number of FO cores per FOC cable

2

2

Version of the FO conductor fiber

Multimode graded-index fiber 62.5/125 µm, OM 1

Multi-mode gradient fiber 62.5/125 µm, OM 2

Design of the FOC core

Hollow core, filled, diameter 1400 µm

Solid core

Design of the fiber-optic cable

Segmentable outer conductor

Segmentable outer conductor

Outer diameter

 

 

  • ? of the optical fibers

62.5 µm

62.5 µm

  • ? of the optical fiber sheath

125 µm

125 µm

  • ? of the FOC core sheath

3.5 mm

2.9 mm

Outer diameter of the cable

12.9 mm

13.3 mm

Symmetrical deviation of the outer diameter of the line

0.5 mm

Material

 

 

  • ? of the fiber-optic cable core

Quartz glass

Mineral glass

  • ? of the optical fiber sheath

Quartz glass

  • ? of the FOC core sheath

PUR

Polyolefine

  • ? of the fiber-optic cable sheath

PUR

SHF1 mixture

  • ? of the strain relief

Aramid fibers, also GRP central element

Aramid fibers

Color

 

 

  • ? of the FOC core sheath

black

  • ? of cable sheath

Black

Black

Bending radius

 

 

  • ? with single bend minimum permissible

150 mm

133 mm

  • ? with multiple bends minimum permissible

150 mm

266 mm

Number of bending cycles

100 000

Tensile load

 

 

  • ? during installation short-term

2 000 N

  • ? during operation maximum

1 000 N

250 N

Weight per length

130 kg/km

220 kg/km

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • ? during operation

-30 ... +60 °C

-40 ... +80 °C

  • ? during storage

-30 ... +70 °C

-40 ... +80 °C

  • ? during transport

-30 ... +70 °C

-40 ... +80 °C

  • ? during installation

-30 ... +60 °C

-10 ... +50 °C

Ambient condition for operation

At ambient temperatures below -10 degrees Celsius, the cable must not be subjected to any movements other than the normal vibration levels encountered on board ship

Burning behavior

flammable

Flame-resistant acc. to IEC 60332-3 (Cat. A)

Chemical resistance

 

 

  • ? to mineral oil

acc. to IEC 60811-404 with test oil IRM 902 (acc. to ISO 1817), +100 °C, 168 h, pull speed 250 mm/min

  • ? to grease

resistant

  • ? to water

conditional resistance

conditional resistance

Radiological resistance to UV radiation

resistant

resistant

Product properties, functions, components general

 

 

Product feature

 

 

  • ? halogen-free

Yes

Yes

  • ? silicon-free

Yes

Yes

Product component Rodent protection

No

No

Wire length

 

 

  • ? for glass FOC for 100BaseFX for Industrial Ethernet maximum

4 000 m

4 000 m

  • ? for glass FOC for 1000BaseSX for Industrial Ethernet maximum

350 m

350 m

  • ? for glass FOC for 1000BaseLX for Industrial Ethernet maximum

550 m

550 m

  • ? for glass FOC with PROFIBUS maximum

3 000 m

3 000 m

Standards, specifications, approvals

 

 

Certificate of suitability

  • ? RoHS conformity

Yes

Yes

Marine classification association

 

 

  • ? Bureau Veritas (BV)

Yes

  • ? Det Norske Veritas (DNV)

Yes

  • ? Germanische Lloyd (GL)

Yes

  • ? Lloyds Register of Shipping (LRS)

Yes


Order number

6XV1873-2R

6XV1843-2R

Product type designation

MM FO Robust Cable GP

SM FO robust cable GP

Suitability for use

Waterproof cable (lengthwise and sideways) with non-metallic protection against rodents for use indoors and outdoors as well as for direct routing underground

Waterproof cable (lengthwise and sideways) with non-metallic protection against rodents for use indoors and outdoors as well as for direct routing underground

Version of the assembled FO cable

For assembly with two BFOC, SC and LC duplex connectors

For assembly with two BFOC, SC and LC duplex connectors

Cable designation

AT-V(ZN)H(ZN)BH 2G50/125

AT-V(ZN)H(ZN)BH 4E9/125

Optical data

 

 

Damping ratio per length

 

 

  • ? at 850 nm maximum

2.7 dB/km

  • ? at 1300 nm maximum

1 dB/km

0.5 dB/km

  • ? at 1550 nm maximum

0.5 dB/km

Bandwidth length product

 

 

  • ? at 850 nm

600 GHz·m

  • ? at 1300 nm

1 200 GHz·m

Mechanical data

 

 

Number of fibers per FOC core

1

1

Number of FO cores per FOC cable

2

4

Version of the FO conductor fiber

Multi-mode gradient fiber 50/125/245 µm, OM2

Single mode fiber 4E9/125/900, OS1 and OS2

Design of the FOC core

Solid core, diameter 900 µm

Solid core, diameter 900 µm

Design of the fiber-optic cable

segmentable

segmentable

Outer diameter

 

 

  • ? of the optical fibers

50 µm

9 µm

  • ? of the optical fiber sheath

125 µm

125 µm

  • ? of the FOC core sheath

2.2 mm

2.2 mm

Outer diameter of the cable

7.5 mm

9 mm

Material

 

 

  • ? of the fiber-optic cable core

Quartz glass

Quartz glass

  • ? of the optical fiber sheath

Quartz glass

Quartz glass

  • ? of the FOC core sheath

PE flame retardant

PE flame retardant

  • ? of the fiber-optic cable sheath

PE flame retardant

PE flame retardant

  • ? of the strain relief

Aramid fibers and glass roving

Aramid fibers, also central support element and glass roving

Color

 

 

  • ? of the FOC core sheath

orange/black, with direction arrow

orange/black, with direction arrow (core pairs numbered with 1 and 2)

  • ? of cable sheath

Black

Black

Bending radius

 

 

  • ? with single bend minimum permissible

25 mm

90 mm

  • ? with multiple bends minimum permissible

40 mm

135 mm

Tensile load

 

 

  • ? during installation short-term

2 000 N

2 000 N

  • ? during operation maximum

1 000 N

1 000 N

Short-term shear force per length

600 N/cm

600 N/cm

Continuous lateral force per length

200 N/cm

200 N/cm

Weight per length

67 kg/km

87 kg/km

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • ? during operation

-40 ... +70 °C

-40 ... +70 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

  • ? during installation

-20 ... +60 °C

-20 ... +60 °C

Burning behavior

flame-resistant acc. to IEC 60332-3-24

flame-resistant acc. to IEC 60332-3-24

Chemical resistance

 

 

  • ? to mineral oil

conditional resistance

conditional resistance

  • ? to grease

conditional resistance

conditional resistance

  • ? to water

resistant

resistant

Radiological resistance to UV radiation

resistant

resistant

Product properties, functions, components general

 

 

Product feature

 

 

  • ? halogen-free

Yes

Yes

  • ? silicon-free

Yes

Yes

Product component Rodent protection

Yes

Yes

Wire length

 

 

  • ? for glass FOC for 100BaseFX for Industrial Ethernet maximum

5 000 m

26 000 m

  • ? for glass FOC for 1000BaseSX for Industrial Ethernet maximum

750 m

  • ? for glass FOC for 1000BaseLX for Industrial Ethernet maximum

2 000 m

5 000 m

  • ? for glass FOC for 10GBaseLR for Industrial Ethernet maximum

10 000 m

  • ? for glass FOC with 10GBaseER for Industrial Ethernet maximum

40 000 m

  • ? for glass FOC with 10GBaseSR for Industrial Ethernet maximum

60 m

  • ? for glass FOC with PROFIBUS maximum

3 000 m

15 000 m

Standards, specifications, approvals

 

 

Certificate of suitability

  • ? RoHS conformity

Yes

Yes


Order number

6GK1901-0DA20-0AA0

Product type designation

BFOC Connector Set

Product description

20 ST/BFOC plug

Suitability for use

For connection of glass fiber-optic cables (50/125 - 62,5/125)

Transmission rate

 

Transfer rate for Industrial Ethernet

10 Mbit/s, 100 Mbit/s

Transfer rate with PROFIBUS

9.6 kbit/s ... 12 Mbit/s

Interfaces

 

Number of optical interfaces for fiber optic cable

1

Design of the optical interface for network components or terminal equipment

BFOC connector

Type of electrical connection FastConnect

No

Mechanical data

 

Material of the enclosure

Metal and plastic

Locking mechanism design

Bayonet

Design, dimensions and weight

 

Type of cable outlet

180° cable outlet

Width

9.5 mm

Height

9.5 mm

Depth

29.7 mm

Net weight

8 g

Permitted ambient conditions

 

Ambient temperature

 

  • ? during operation

-40 ... +85 °C

  • ? during storage

-40 ... +90 °C

  • ? during transport

-40 ... +90 °C

Protection class IP

IP20

Product properties, functions, components general

 

Product feature

 

  • ? silicon-free

Yes

Product component

 

  • ? strain relief

Yes

Standards, specifications, approvals

 

Certificate of suitability

 

  • ? RoHS conformity

Yes

  • ? UL approval

No

  • ? Railway application in accordance with EN 50155

No


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ
Êàòàëîã îáîðóäîâàíèÿ 2017
Siemens Industry Catalog Drive Technology Automation Technology Automation Systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial Communication Introduction Industrial Ethernet Introduction Data communication Communication overview Topologies Network selection criteria Cabling Technology Overview of passive network components Overview of Twisted Pair Industrial Ethernet FastConnect IE FC RJ45 Plug 2 x 2 IE FC RJ45 Plug 4 x 2, Cat6A IE RJ45 Port Lock IE Push Pull Plug PRO IE FC M12 Plug PRO IE FC TP Cable 2 x 2 IE FC TP Cable 4 x 2 Energy cables IE TP Cord Pre-assembled IE connecting cables IE FC Outlet RJ45 IE FC RJ45 Modular Outlet Industrial Twisted Pair – cables/connectors Overview of FC-FOCs FC glass fiber-optic cables FC FO termination kit Overview of FOCs Glass fiber-optic cables IE FO Cords POF and PCF fiber-optic cables POF/PCF FOC termination kit Media Converters Layer 2 Switches Layer 3 switches / routers Serial Device Servers Power over Ethernet Injector Industrial Ethernet Security System Interfaces SCALANCE Accessories RUGGEDCOM Accessories Network management and diagnostics Network Transitions Industrial Network Services Partner Solutions PROFINET PROFIBUS AS-Interface IO-Link Industrial Wireless Communication Industrial Remote Communication Industrial Security Industrial Controls Manufacturing Execution Systems (MES) SIMATIC IT PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supplies Products for specific requirements Energy Building Technologies Low-Voltage Controls and Distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services ... and everything else you need




  © ÎÎÎ "ÑÊ ÝÍÅÐÃÎ" 2007-2022
  (4872) 700-366  skenergo@mail.ru
ßíäåêñ.Ìåòðèêà