IE FC TP Cable 2 x 2

Order number

6XV1840-2AH10

6XV1841-2A

6XV1870-2B

6XV1841-2B

Product type designation

IE FC TP Standard Cable GP 2 x 2 (Type A)

IE FC TP Robust Standard Cable GP 2 x 2 (Type A)

IE FC TP Flexible Cable GP 2 x 2 (Type B)

IE FC TP Robust Flexible Cable GP 2 x 2 (Type B)

Product description

Standard bus cable (4-core), sold by the meter, unassembled

Standard bus cable (4-core), sold by the meter, unassembled

Flexible bus cable (4-core), sold by the meter, unassembled

Flexible bus cable (4-core), sold by the meter, unassembled

Suitability for use

Standard cable with rigid cores for fast installation

Standard cable with rigid cores for fast installation

For occasionally moved machine parts

For occasionally moved machine parts

Cable designation

2YY (ST) CY 2x2x0,64/1,5-100 GN SF/UTP

2YH (ST) C99Y 2x2x0,64/1,5-100 GN SF/UTP

2YY (ST) CY 2x2x0,75/1,5-100 LI GN SF/UTP

2YH (ST) C99Y 2x2x0,75/1,5-100 LI GN SF/UTP

Electrical data

 

 

 

 

Damping ratio per length

 

 

 

 

  • ? at 10 MHz maximum

52 dB/km

65 dB/km

60 dB/km

65 dB/km

  • ? at 100 MHz maximum

195 dB/km

220 dB/km

210 dB/km

220 dB/km

Impedance

 

 

 

 

  • ? at 1 MHz ... 100 MHz

100 ?

100 ?

100 ?

100 ?

Relative symmetrical tolerance

 

 

 

 

  • ? of the characteristic impedance at 1 MHz … 100 MHz

15 %

15 %

15 %

15 %

Near-end crosstalk per length

 

 

 

 

  • ? at 1 MHz ... 100 MHz

500 dB/km

500 dB/km

500 dB/km

500 dB/km

Transfer impedance per length at 10 MHz

10 m?/m

10 m?/m

20 m?/m

20 m?/m

Loop resistance per length maximum

115 m?/m

115 m?/m

120 m?/m

120 m?/m

Operating voltage

 

 

 

 

  • ? RMS value

80 V

80 V

80 V

80 V

NVP value in percent

66 %

66 %

66 %

66 %

Mechanical data

 

 

 

 

Number of electrical cores

4

4

4

4

Design of the shield

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Type of electrical connection FastConnect

Yes

Yes

Yes

Yes

Core diameter

 

 

 

 

  • ? of AWG22 core

0.64 mm

0.64 mm

0.75 mm

0.75 mm

Outer diameter

 

 

 

 

  • ? of inner conductor

0.64 mm

0.64 mm

0.75 mm

0.75 mm

  • ? of the wire insulation

1.5 mm

1.5 mm

1.5 mm

1.5 mm

  • ? of the inner sheath of the cable

3.9 mm

3.9 mm

3.9 mm

3.9 mm

  • ? of cable sheath

6.5 mm

6.5 mm

6.5 mm

6.5 mm

Symmetrical tolerance of the outer diameter of cable sheath

0.2 mm

0.2 mm

0.2 mm

0.2 mm

Material

 

 

 

 

  • ? of the wire insulation

PE

PE

PE

PE

  • ? of the inner sheath of the cable

PVC

FRNC

PVC

FRNC

  • ? of cable sheath

PVC

TPE (FR-TPE)

PVC

TPE (FR-TPE)

Color

 

 

 

 

  • ? of the insulation of data wires

white/yellow/blue/orange

white/yellow/blue/orange

white/yellow/blue/orange

white/yellow/blue/orange

  • ? of cable sheath

green

green

green

green

Bending radius

 

 

 

 

  • ? with single bend minimum permissible

19.5 mm

26 mm

32.5 mm

32.5 mm

  • ? with multiple bends minimum permissible

49 mm

52 mm

52 mm

52 mm

Tensile load maximum

150 N

150 N

150 N

150 N

Weight per length

67 kg/km

59 kg/km

68 kg/km

68 kg/km

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-40 ... +75 °C

-40 ... +75 °C

-25 ... +75 °C

-40 ... +75 °C

  • ? during storage

-40 ... +75 °C

-40 ... +75 °C

-25 ... +75 °C

-40 ... +75 °C

  • ? during transport

-40 ... +75 °C

-40 ... +75 °C

-25 ... +75 °C

-40 ... +75 °C

  • ? during installation

-20 ... +60 °C

-20 ... +60 °C

-10 ... +60 °C

-20 ... +60 °C

  • ? Note

Electrical properties measured at 20 °C, tests according to DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN VDE 0472

Burning behavior

flame resistant according to UL 1685 (CSA FT 4)

flame resistant according to IEC 60332-1-2

flame resistant according to UL 1685 (CSA FT 4)

flame resistant according to IEC 60332-1-2

Chemical resistance

 

 

 

 

  • ? to mineral oil

oil resistant according to IEC 60811-2-1 (4 h / 70°C)

oil resistant according to DIN EN 50290-2-22 (VDE 0819), (7x24h/90°C), UL13 Sec.40 (96h/100°C)

oil resistant according to IEC 60811-404 (7x24h/90°C)

oil resistant according to DIN EN 50290-2-22 (VDE 0819), (7x24h/90°C), UL13 Sec.40 (96h/100°C)

  • ? to grease

Conditional resistance

Conditional resistance

Conditional resistance

Conditional resistance

  • ? to water

conditional resistance

conditional resistance

conditional resistance

conditional resistance

Radiological resistance to UV radiation

resistant

resistant

resistant

resistant

Product properties, functions, components general

 

 

 

 

Product feature

 

 

 

 

  • ? halogen-free

No

No

No

No

  • ? silicon-free

Yes

Yes

Yes

Yes

Wire length for Industrial Ethernet

 

 

 

 

  • ? with 100BaseTX

100 m

100 m

85 m

85 m

Standards, specifications, approvals

 

 

 

 

UL/ETL listing 300 V Rating

Yes; cULus / CMG / PLTC/ ITC(UL) / Sun Res

Yes; c(ETL)us, CM, PLTC, SUN RES

Yes; c(UL)us, CMG / PLTC / Sun Res / OIL RES

Yes; c(ETL)us, CM, PLTC, SUN RES

UL/ETL style 600 V Rating

Yes

No

No

No

Certificate of suitability

  • ? CE marking

Yes

Yes

Yes

Yes

  • ? RoHS conformity

Yes

Yes

Yes

Yes

Standard for structured cabling

Cat5e

Cat5e

Cat5e

Cat5e

Marine classification association

 

 

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

No

No

No

No

  • ? Bureau Veritas (BV)

No

No

No

No

  • ? Det Norske Veritas (DNV)

No

No

No

No

  • ? Germanische Lloyd (GL)

No

No

No

No

  • ? Lloyds Register of Shipping (LRS)

No

No

No

No

  • ? Nippon Kaiji Kyokai (NK)

No

No

No

No

  • ? Polski Rejestr Statkow (PRS)

No

No

No

No


Order number

6XV1870-2F

6XV1870-2D

6XV1840-3AH10

6XV1871-2S

Product type designation

IE TP Torsion Cable 2 x 2 (Type C)

IE FC TP Trailing Cable GP 2 x 2 (Type C)

IE FC TP Trailing Cable 2 x 2 (Type C)

IE FC TP Festoon Cable GP 2 x 2 (Type B)

Product description

Highly flexible bus cable (4-core), sold by the meter, unassembled

Highly flexible bus cable (4-core), sold by the meter, unassembled

Highly flexible bus cable (4-core), sold by the meter, unassembled

Flexible bus cable (4-core), sold by the meter, unassembled

Suitability for use

Continuous motion control when using robots

Continuous motion control in a cable carrier

Continuous motion control in a cable carrier

For continuous motion in a trailing cable, festoon mounting

Cable designation

02YS C11Y 1x4x0,75/1,5-100 LI VZN FRNC GN SF/UTP

2YY (ST) CY 2x2x0,75/1,5-100 LI GN SF/UTP

2YH (ST) C11Y 2x2x0,75/1,5-100 LI GN VZN FRNC SF/UTP

2YY (ST) CY 2x2x0,75/1,5 LI GN SF/UTP

Electrical data

 

 

 

 

Damping ratio per length

 

 

 

 

  • ? at 10 MHz maximum

81 dB/km

63 dB/km

60 dB/km

63 dB/km

  • ? at 100 MHz maximum

410 dB/km

213 dB/km

220 dB/km

213 dB/km

Impedance

 

 

 

 

  • ? at 1 MHz ... 100 MHz

100 ?

100 ?

100 ?

100 ?

Relative symmetrical tolerance

 

 

 

 

  • ? of the characteristic impedance at 1 MHz … 100 MHz

15 %

5 %

15 %

5 %

Near-end crosstalk per length

 

 

 

 

  • ? at 1 MHz ... 100 MHz

500 dB/km

500 dB/km

500 dB/km

500 dB/km

Transfer impedance per length at 10 MHz

100 m?/m

20 m?/m

10 m?/m

100 m?/m

Loop resistance per length maximum

120 m?/m

120 m?/m

120 m?/m

120 m?/m

Operating voltage

 

 

 

 

  • ? RMS value

80 V

80 V

80 V

80 V

NVP value in percent

70 %

66 %

66 %

66 %

Mechanical data

 

 

 

 

Number of electrical cores

4

4

4

4

Design of the shield

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Type of electrical connection FastConnect

No

Yes

Yes

Yes

Core diameter

 

 

 

 

  • ? of AWG22 core

0.76 mm

0.75 mm

0.75 mm

0.75 mm

Outer diameter

 

 

 

 

  • ? of inner conductor

0.76 mm

0.75 mm

0.75 mm

0.75 mm

  • ? of the wire insulation

1.5 mm

1.5 mm

1.5 mm

1.5 mm

  • ? of the inner sheath of the cable

3.9 mm

3.9 mm

3.9 mm

  • ? of cable sheath

6.5 mm

6.5 mm

6.5 mm

6.5 mm

Symmetrical tolerance of the outer diameter of cable sheath

0.2 mm

0.2 mm

0.2 mm

0.2 mm

Material

 

 

 

 

  • ? of the wire insulation

PE

PE

PE

PE

  • ? of the inner sheath of the cable

PVC

FRNC

PVC

  • ? of cable sheath

PUR (TPE-U)

PVC

PUR (TPE-U)

PVC

Color

 

 

 

 

  • ? of the insulation of data wires

white/yellow/blue/orange

white/yellow/blue/orange

white/yellow/blue/orange

white/yellow/blue/orange

  • ? of cable sheath

green

green

green

green

Bending radius

 

 

 

 

  • ? with single bend minimum permissible

32.5 mm

32.5 mm

19.5 mm

30 mm

  • ? with multiple bends minimum permissible

65 mm

49 mm

49 mm

70 mm

  • ? with continuous bending

100 mm

100 mm

70 mm

Number of bending cycles

Not suitable for garland usage

3 000 000; Drag chain suitable for 3 million bending cycles at a bending radius of 100 mm, a speed of 4 m/s and an acceleration of 4 m/s?

4 000 000; Drag chain suitable for 4 million bending cycles at a bending radius of 100 mm, a speed of 4 m/s and an acceleration of 4 m/s?

5 000 000; 5 million bending cycles at a bending radius of 70 mm and an acceleration of 4 m/s?

Number of torsion cycles with torsion by ± 180° on 1 m cable length

5 000 000

Tensile load maximum

130 N

150 N

150 N

150 N

Weight per length

54 kg/km

68 kg/km

63 kg/km

68 kg/km

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-40 ... +80 °C

-25 ... +75 °C

-40 ... +75 °C

-40 ... +75 °C

  • ? during storage

-40 ... +80 °C

-25 ... +75 °C

-50 ... +75 °C

-50 ... +75 °C

  • ? during transport

-40 ... +80 °C

-25 ... +75 °C

-50 ... +75 °C

-50 ... +75 °C

  • ? during installation

-20 ... +60 °C

-10 ... +60 °C

-20 ... +60 °C

-20 ... +60 °C

  • ? Note

Electrical properties measured at 20 °C, tests according to DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN VDE 0472

Burning behavior

flame resistant according to IEC 60332-1-2

flame resistant according to UL 1685 (CSA FT 4)

flame resistant according to IEC 60332-1-2

flame resistant according to UL 1685 (CSA FT 4)

Chemical resistance

 

 

 

 

  • ? to mineral oil

oil resistant according to IEC 60811-2-1 (7x24h/90°C)

oil resistant according to IEC 60811-404 (7x24h/90°C)

oil resistant according to IEC 60811-2-1 (7x24h/90°C)

conditional resistance

  • ? to grease

resistant

Conditional resistance

resistant

Conditional resistance

  • ? to water

resistant

conditional resistance

resistant

conditional resistance

Radiological resistance to UV radiation

resistant

resistant

resistant

resistant

Product properties, functions, components general

 

 

 

 

Product feature

 

 

 

 

  • ? halogen-free

Yes

No

Yes

No

  • ? silicon-free

Yes

Yes

Yes

Yes

Wire length for Industrial Ethernet

 

 

 

 

  • ? with 100BaseTX

75 m

85 m

85 m

85 m

Standards, specifications, approvals

 

 

 

 

UL/ETL listing 300 V Rating

Yes; UL Style 21161

Yes; c(UL)us, CMG / PLTC / Sun Res / OIL RES

Yes; cULus / CMX

Yes; c(UL)us, CMG / PLTC / Sun Res / OIL RES

UL/ETL style 600 V Rating

No

Yes

No

Yes

Certificate of suitability

  • ? CE marking

Yes

Yes

Yes

Yes

  • ? RoHS conformity

Yes

Yes

Yes

Yes

Standard for structured cabling

Cat5e

Cat5e

Cat5e

Cat5e

Marine classification association

 

 

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

No

No

No

No

  • ? Bureau Veritas (BV)

No

No

No

No

  • ? Det Norske Veritas (DNV)

No

No

No

No

  • ? Germanische Lloyd (GL)

No

No

No

No

  • ? Lloyds Register of Shipping (LRS)

No

No

No

No

  • ? Nippon Kaiji Kyokai (NK)

No

No

No

No

  • ? Polski Rejestr Statkow (PRS)

No

No

No

No


Order number

6XV1871-2F

6XV1871-2L

6XV1881-2A

6XV1840-4AH10

Product type designation

IE FC TP FRNC Cable GP 2x2 (Type B)

IE FC TP Food Cable 2 x 2 (Type C)

IE FC TP Robust Food Cable GP 2X2 (Typ B)

IE FC TP Marine Cable 2 x 2 (Type B)

Product description

Flexible halogen-free bus cable acc. to IEC 60754-1/2 (4-core), sold by the meter, unassembled

Flexible bus cable (4-core), sold by the meter, unassembled

Robust, flexible bus cable (4-core), sold by the meter, unassembled

Halogen-free bus cable acc. to IEC 60754-1/2 (4-core), sold by the meter, unassembled

Suitability for use

For occasionally moved machine parts

Food and beverages industry

For marine and offshore use

Cable designation

L-9YH (ST) CH 2x2x0,34/1,5-100 GN VZN FRNC SF/UTP

2YH (ST) C2Y 2X2X0,75/1,5-100 LI SF/UTP

2YY(ST)CY6Y 2X2X0.75/1.55 LI VZN

L-9YH (ST) CH 2 x 2 x 0,34/1,5-100 GN VZN FRNC SF/UTP

Electrical data

 

 

 

 

Damping ratio per length

 

 

 

 

  • ? at 10 MHz maximum

60 dB/km

63 dB/km

95 dB/km

60 dB/km

  • ? at 100 MHz maximum

220 dB/km

213 dB/km

320 dB/km

220 dB/km

Impedance

 

 

 

 

  • ? at 1 MHz ... 100 MHz

100 ?

100 ?

100 ?

100 ?

Relative symmetrical tolerance

 

 

 

 

  • ? of the characteristic impedance at 1 MHz … 100 MHz

15 %

5 %

5 %

15 %

Near-end crosstalk per length

 

 

 

 

  • ? at 1 MHz ... 100 MHz

0.5 dB/m

0.5 dB/m

0.353 dB/m

0.5 dB/m

Transfer impedance per length at 10 MHz

10 m?/m

10 m?/m

80 m?/m

10 m?/m

Loop resistance per length maximum

120 m?/m

120 m?/m

120 m?/m

120 m?/m

Operating voltage

 

 

 

 

  • ? RMS value

80 V

80 V

80 V

80 V

NVP value in percent

66 %

66 %

63 %

66 %

Mechanical data

 

 

 

 

Number of electrical cores

4

4

4

4

Design of the shield

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Type of electrical connection FastConnect

Yes

Yes

Yes

Yes

Core diameter

 

 

 

 

  • ? of AWG22 core

0.75 mm

0.75 mm

0.75 mm

0.75 mm

Outer diameter

 

 

 

 

  • ? of inner conductor

0.75 mm

0.75 mm

0.75 mm

0.75 mm

  • ? of the wire insulation

1.5 mm

1.5 mm

1.56 mm

1.5 mm

  • ? of the inner sheath of the cable

3.9 mm

3.9 mm

4 mm

3.9 mm

  • ? of cable sheath

6.5 mm

6.5 mm

6.5 mm

6.5 mm

Symmetrical tolerance of the outer diameter of cable sheath

0.2 mm

0.2 mm

0.2 mm

0.2 mm

Material

 

 

 

 

  • ? of the wire insulation

PP

PE

PE

PP

  • ? of the inner sheath of the cable

FRNC

FRNC

PVC

FRNC

  • ? of cable sheath

FRNC

PE

PVC/FEP; FEP transparent

FRNC

Color

 

 

 

 

  • ? of the insulation of data wires

white/yellow/blue/orange

white/yellow/blue/orange

white/yellow/blue/orange

white/yellow/blue/orange

  • ? of cable sheath

green

Black

green

green

Bending radius

 

 

 

 

  • ? with single bend minimum permissible

39 mm

20 mm

26 mm

39 mm

  • ? with multiple bends minimum permissible

97.5 mm

49 mm

52 mm

97.5 mm

  • ? with continuous bending

100 mm

Number of bending cycles

500 000; Acceleration 4 m/s?

Number of torsion cycles with torsion by ± 180° on 1 m cable length

1 000 000

Tensile load maximum

150 N

150 N

150 N

150 N

Weight per length

68 kg/km

55 kg/km

72 kg/km

68 kg/km

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-25 ... +70 °C

-40 ... +75 °C

-40 ... +80 °C

-25 ... +70 °C

  • ? during storage

-40 ... +75 °C

-50 ... +75 °C

-40 ... +80 °C

-40 ... +85 °C

  • ? during transport

-40 ... +75 °C

-50 ... +75 °C

-40 ... +80 °C

-40 ... +85 °C

  • ? during installation

0 ... 50 °C

-20 ... +60 °C

-40 ... +80 °C

0 ... 50 °C

  • ? Note

Electrical properties measured at 20 °C, tests according to DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN VDE 0472

Ambient condition for operation

Temperature range for permanent installation -40 °C to 85 °C

Burning behavior

flame resistant according to IEC 60332-3-22 (Category A/F), IEC 61034

inflammable

flame resistant according to IEC 60332-1-2

flame resistant according to IEC 60332-3-22 (Category A/F), smoke density according to IEC 61034-1/2

Chemical resistance

 

 

 

 

  • ? to mineral oil

oil resistant according to IEC 60811-2-1 (4 h / 70°C)

oil resistant according to IEC 60811-2-1 (4 h / 70°C)

oil resistant according to IEC 60811-404 (7x24 h / 90°C)

conditional resistance, IEC 60811-2-1 (4 hours / 70 °C)

  • ? to grease

Conditional resistance

Conditional resistance

Conditional resistance

Conditional resistance

  • ? to water

conditional resistance

conditional resistance

resistant

conditional resistance

Radiological resistance to UV radiation

resistant

resistant

resistant

resistant

Product properties, functions, components general

 

 

 

 

Product feature

 

 

 

 

  • ? halogen-free

Yes

Yes

No

Yes

  • ? silicon-free

Yes

Yes

Yes

Yes

Wire length for Industrial Ethernet

 

 

 

 

  • ? with 100BaseTX

85 m

85 m

85 m

85 m

Standards, specifications, approvals

 

 

 

 

UL/ETL listing 300 V Rating

Yes; c(UL)us, CMG / PLTC / Sun Res / OIL RES

No

Yes; c(ETL)us, CMG, (ETL)us PLTC-ER, SUN RES, OIL RES 1

Yes; cULus / CMG / PLTC / Sun Res

UL/ETL style 600 V Rating

No

No

No

No

Certificate of suitability

  • ? CE marking

Yes

Yes

Yes

Yes

  • ? RoHS conformity

Yes

Yes

Yes

Yes

  • ? for hygienic design

EHEDG, Installation and layout of the cables must fulfil the requirements of EHEDG published in the Guidelines Doc. 13 'Hygienic Design of open equipment for processing food' and Doc. 44 'Hygienic Design Principles for food factories' to be accessible for cleaning. Also connections must be easily cleanable by using EHEDG certified cable glands or connectors.

Standard for structured cabling

Cat5e

Cat5e

Cat5e

Cat5e

Marine classification association

 

 

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

No

No

No

Yes

  • ? Bureau Veritas (BV)

No

No

No

Yes

  • ? Det Norske Veritas (DNV)

No

No

No

Yes

  • ? Germanische Lloyd (GL)

No

No

No

Yes

  • ? Lloyds Register of Shipping (LRS)

No

No

No

Yes

  • ? Nippon Kaiji Kyokai (NK)

No

No

No

No

  • ? Polski Rejestr Statkow (PRS)

No

No

No

No


Order number

6XV1871-2G

6XV1871-2T

Product type designation

IE TP Ground Cable 2x2 (Type C)

IE TP Train Cable 2x2 (Type C, AWG22/7)

Product description

Standard bus cable (4-core), for laying underground, sold by the meter, unassembled

Flexible bus cable with tinned copper leads (4-core) for rail applications, sold by the meter, unassembled

Suitability for use

Standard cable with rigid cores for fast installation

For laying in rail vehicles and buses

Cable designation

2YY(ST)CY2Y2x2x0.64/1.50-100 SF/UTP

SF/UTP

Electrical data

 

 

Damping ratio per length

 

 

  • ? at 10 MHz maximum

63 dB/km

53 dB/km

  • ? at 100 MHz maximum

213 dB/km

188 dB/km

Impedance

 

 

  • ? at 1 MHz ... 100 MHz

100 ?

100 ?

Relative symmetrical tolerance

 

 

  • ? of the characteristic impedance at 1 MHz … 100 MHz

5 %

5 %

Near-end crosstalk per length

 

 

  • ? at 1 MHz ... 100 MHz

500 dB/km

500 dB/km

Transfer impedance per length at 10 MHz

10 m?/m

8 m?/m

Loop resistance per length maximum

124 m?/m

124 m?/m

Operating voltage

 

 

  • ? RMS value

100 V

125 V

NVP value in percent

64 %

Mechanical data

 

 

Number of electrical cores

4

4

Design of the shield

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Type of electrical connection FastConnect

Yes

No

Core diameter

 

 

  • ? of AWG22 core

0.64 mm

0.75 mm

Outer diameter

 

 

  • ? of inner conductor

0.64 mm

0.75 mm

  • ? of the wire insulation

1.5 mm

1.5 mm

  • ? of the inner sheath of the cable

4 mm

  • ? of cable sheath

9 mm

6.6 mm

  • ? of cable sheath Note

Cable diameter >6.5 mm because of additional PE outer cover. Cable can only be connected to RJ45/M12 connector after outer cover is removed.

Symmetrical tolerance of the outer diameter of cable sheath

0.2 mm

0.2 mm

Material

 

 

  • ? of the wire insulation

PE

PE

  • ? of the inner sheath of the cable

PVC

  • ? of cable sheath

PVC

Elastomer meshed electron beam

Color

 

 

  • ? of the insulation of data wires

white/yellow/blue/orange

white/yellow/blue/orange

  • ? of cable sheath

Black

Black

Bending radius

 

 

  • ? with single bend minimum permissible

80 mm

40 mm

  • ? with multiple bends minimum permissible

80 mm

40 mm

Tensile load maximum

150 N

150 N

Weight per length

97 kg/km

71 kg/km

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • ? during operation

-40 ... +70 °C

-40 ... +80 °C

  • ? during storage

-40 ... +70 °C

-40 ... +80 °C

  • ? during transport

-40 ... +70 °C

-40 ... +80 °C

  • ? during installation

-5 ... +50 °C

-20 ... +60 °C

  • ? Note

Electrical properties measured at 20 °C, tests according to EN50288-2-1

For a short duration in case of short-circuit fault 160°C

Ambient condition for operation

Electrical characteristics measured at 20 ?C, tests according to EN50288-2-1

Burning behavior

inflammable

BS6853, DIN5510-2 Brandschutzstufe 1-4, prEN45545-2 Hazard Level HL1-HL3, EN50306-4, NF F 16-101, NFPA130

Chemical resistance

 

 

  • ? to mineral oil

conditional resistance

EN 50306-4 (72h/100 °C, IRM 902, 168h/70 °C, IRM 903)

  • ? to grease

Conditional resistance

Conditional resistance

  • ? to water

Resistant

conditional resistance

Radiological resistance to UV radiation

resistant

resistant

Product properties, functions, components general

 

 

Product feature

 

 

  • ? halogen-free

No

Yes

  • ? silicon-free

Yes

Yes

Wire length for Industrial Ethernet

 

 

  • ? with 100BaseTX

100 m

100 m

Standards, specifications, approvals

 

 

UL/ETL listing 300 V Rating

No

No

UL/ETL style 600 V Rating

No

No

Certificate of suitability

  • ? CE marking

Yes

Yes

  • ? RoHS conformity

Yes

Yes

Standard for structured cabling

Cat5e

Cat5

Marine classification association

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

No

No

  • ? Bureau Veritas (BV)

No

No

  • ? Det Norske Veritas (DNV)

No

No

  • ? Germanische Lloyd (GL)

No

No

  • ? Lloyds Register of Shipping (LRS)

No

No

  • ? Nippon Kaiji Kyokai (NK)

No

No

  • ? Polski Rejestr Statkow (PRS)

No

No


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ
Êàòàëîã îáîðóäîâàíèÿ 2017
Siemens Industry Catalog Drive Technology Automation Technology Automation Systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial Communication Introduction Industrial Ethernet Introduction Data communication Communication overview Topologies Network selection criteria Cabling Technology Overview of passive network components Overview of Twisted Pair Industrial Ethernet FastConnect IE FC RJ45 Plug 2 x 2 IE FC RJ45 Plug 4 x 2, Cat6A IE RJ45 Port Lock IE Push Pull Plug PRO IE FC M12 Plug PRO IE FC TP Cable 2 x 2 IE FC TP Cable 4 x 2 Energy cables IE TP Cord Pre-assembled IE connecting cables IE FC Outlet RJ45 IE FC RJ45 Modular Outlet Industrial Twisted Pair – cables/connectors Overview of FC-FOCs FC glass fiber-optic cables FC FO termination kit Overview of FOCs Glass fiber-optic cables IE FO Cords POF and PCF fiber-optic cables POF/PCF FOC termination kit Media Converters Layer 2 Switches Layer 3 switches / routers Serial Device Servers Power over Ethernet Injector Industrial Ethernet Security System Interfaces SCALANCE Accessories RUGGEDCOM Accessories Network management and diagnostics Network Transitions Industrial Network Services Partner Solutions PROFINET PROFIBUS AS-Interface IO-Link Industrial Wireless Communication Industrial Remote Communication Industrial Security Industrial Controls Manufacturing Execution Systems (MES) SIMATIC IT PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supplies Products for specific requirements Energy Building Technologies Low-Voltage Controls and Distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services ... and everything else you need




  © ÎÎÎ "ÑÊ ÝÍÅÐÃÎ" 2007-2022
  (4872) 700-366  skenergo@mail.ru
ßíäåêñ.Ìåòðèêà