PROFIBUS bus cables

Order number

6XV1830-0EH10

6XV1831-2A

6XV1830-0JH10

6XV1830-0GH10

Product type designation

PROFIBUS FC Standard Cable GP

PROFIBUS FC Standard Cable IS GP

PROFIBUS FC Robust Cable

PROFIBUS FC Food Cable

Product description

Standard bus cable (2-core), sold by the meter, unassembled

Standard bus cable for fast installation, sold by the meter, unassembled

Special bus cable (2-core), sold by the meter, unassembled

Bus cable (2-core), sold by the meter, unassembled

Suitability for use

Standard cable specially designed for fast, permanent installation

Used for intrinsically safe distributed I/O systems for permanent installation

For use in chemically and mechanically demanding environments

For use in the food, beverages and tobacco industries

Cable designation

02YSY (ST) CY 1x2x0,64/2,55-150 VI KF 40 FR

02YSY (ST) CY 1x2x0,64/2,55 BL KF40 FR

02YSY (ST) C11Y 1x2x0,64/2,55-150 VI KF 40 FR

02YSY (ST) C2Y 1x2x0,64/2,55-150 KF 40

Electrical data

 

 

 

 

Damping ratio per length

 

 

 

 

  • ? at 9.6 kHz maximum

2.5 dB/km

2.5 dB/km

2.5 dB/km

2.5 dB/km

  • ? at 38.4 kHz maximum

4 dB/km

4 dB/km

4 dB/km

4 dB/km

  • ? at 4 MHz maximum

22 dB/km

22 dB/km

22 dB/km

22 dB/km

  • ? at 16 MHz maximum

42 dB/km

42 dB/km

42 dB/km

42 dB/km

Impedance

 

 

 

 

  • ? Rated value

150 ?

150 ?

150 ?

150 ?

  • ? at 9.6 kHz

270 ?

270 ?

270 ?

270 ?

  • ? at 38.4 kHz

185 ?

185 ?

185 ?

185 ?

  • ? at 3 MHz … 20 MHz

150 ?

150 ?

150 ?

150 ?

Relative symmetrical tolerance

 

 

 

 

  • ? of the characteristic impedance at 9.6 kHz

10 %

10 %

10 %

10 %

  • ? of the characteristic impedance at 38.4 kHz

10 %

10 %

10 %

10 %

  • ? of the characteristic impedance at 3 MHz … 20 MHz

10 %

10 %

10 %

10 %

Loop resistance per length maximum

110 m?/m

110 m?/m

110 m?/m

110 m?/m

Shield resistance per length maximum

9.5 ?/km

9.5 ?/km

9.5 ?/km

9.5 ?/km

Insulation resistance coefficient

16 000 G?·m

Capacity per length at 1 kHz

28.5 pF/m

28.5 pF/m

28.5 pF/m

28.5 pF/m

Operating voltage

 

 

 

 

  • ? RMS value

100 V

80 V

80 V

80 V

Mechanical data

 

 

 

 

Number of electrical cores

2

2

2

2

Design of the shield

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Type of electrical connection FastConnect

Yes

Yes

Yes

Yes

Core diameter

 

 

 

 

  • ? of AWG22 core

0.64 mm

Outer diameter

 

 

 

 

  • ? of inner conductor

0.65 mm

0.64 mm

0.65 mm

0.65 mm

  • ? of the wire insulation

2.55 mm

2.55 mm

2.55 mm

2.55 mm

  • ? of the inner sheath of the cable

5.4 mm

5.4 mm

5.4 mm

5.4 mm

  • ? of cable sheath

8 mm

8 mm

8 mm

8 mm

Symmetrical tolerance of the outer diameter of cable sheath

0.4 mm

0.4 mm

0.4 mm

0.4 mm

Material

 

 

 

 

  • ? of the wire insulation

PE

PE

PE

PE

  • ? of the inner sheath of the cable

PVC

PVC

PVC

PVC

  • ? of cable sheath

PVC

PVC

PUR (TPE-U)

PE; Outer cover made of PE is especially suitable for the food processing industry

Color

 

 

 

 

  • ? of the insulation of data wires

red/green

red/green

red/green

red/green

  • ? of cable sheath

Violet

blue

Violet

Black

Bending radius

 

 

 

 

  • ? with single bend minimum permissible

37.5 mm

37.5 mm

75 mm

30 mm

  • ? with multiple bends minimum permissible

75 mm

75 mm

150 mm

60 mm

Tensile load maximum

100 N

100 N

100 N

100 N

Weight per length

80 kg/km

80 kg/km

71 kg/km

67 kg/km

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-40 ... +75 °C

-40 ... +75 °C

-40 ... +60 °C

-40 ... +60 °C

  • ? during storage

-40 ... +75 °C

-40 ... +75 °C

-40 ... +60 °C

-40 ... +60 °C

  • ? during transport

-40 ... +75 °C

-40 ... +75 °C

-40 ... +60 °C

-40 ... +60 °C

  • ? during installation

-40 ... +75 °C

-40 ... +75 °C

-40 ... +60 °C

-40 ... +60 °C

  • ? Note

Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472

Burning behavior

flame resistant according to IEC 60332-3-24 (Category C) and UL 1685 (CSA FT 4)

flame resistant according to IEC 60332-3-24 (Category C)

flame resistant according to IEC 60332-1

inflammable

Chemical resistance

 

 

 

 

  • ? to mineral oil

oil resistant according to IEC 60811-2-1 (4 hours / 70°C)

oil resistant according to IEC 60811-2-1 (4 h / 70°C)

oil resistant according to IEC 60811-2-1 (7x24h/90°C)

oil resistant according to IEC 60811-2-1 (4 h / 70°C)

  • ? to grease

Conditional resistance

Conditional resistance

resistant

Conditional resistance

  • ? to water

conditional resistance

conditional resistance

conditional resistance

conditional resistance

Radiological resistance to UV radiation

resistant

resistant

resistant

resistant

Product properties, functions, components general

 

 

 

 

Product feature

 

 

 

 

  • ? halogen-free

No

No

No

No

  • ? silicon-free

Yes

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

 

UL/ETL listing 300 V Rating

Yes; c(UL)us, CMG / CL3 / Sun Res

Yes; CMG / CL3 / Sun Res

Yes; c(UL)us, CMX

No

UL/ETL style 600 V Rating

Yes

Yes

No

No

Certificate of suitability

  • ? CE marking

Yes

Yes

Yes

Yes

  • ? UL approval

Yes

  • ? RoHS conformity

Yes

Yes

Yes

Yes

Marine classification association

 

 

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

No

No

No

No

  • ? Bureau Veritas (BV)

No

No

No

No

  • ? Det Norske Veritas (DNV)

No

No

No

No

  • ? Germanische Lloyd (GL)

No

No

No

No

  • ? Lloyds Register of Shipping (LRS)

No

No

No

No

  • ? Nippon Kaiji Kyokai (NK)

No

No

No

No

  • ? Polski Rejestr Statkow (PRS)

No

No

No

No


Order number

6XV1830-3FH10

6XV1831-2K

6XV1830-3EH10

6XV1831-2L

Product type designation

PROFIBUS FC Ground Cable

PROFIBUS FC Flexible Cable

PROFIBUS FC Trailing Cable

PROFIBUS FC Trailing Cable

Product description

Special bus cable (2-core) with additional protective jacket, sold by the meter, unassembled

Flexible bus cable (2-core), sold by the meter, unassembled

Highly flexible bus cable (2-core), sold by the meter, unassembled

Highly flexible bus cable (2-core), sold by the meter, unassembled

Suitability for use

Used for buried cables

For occasionally moved machine parts

Continuous motion control in a cable carrier

Continuous motion control in a cable carrier

Cable designation

02YSY (ST) CY2Y 1x2x0,64/2,55-150 SW KF 40

02YH (ST) C11Y 1x2x0,65/2,56-150 LI KF40 FRNC FC VI

02YY (ST) C11Y 1x2x0,65/2,56-150 LI KF 40 FR petrol

02YY (ST) C11Y 1x2x0,65/2,56-150 LI KF 40 FR VT FC

Electrical data

 

 

 

 

Damping ratio per length

 

 

 

 

  • ? at 9.6 kHz maximum

2.5 dB/km

3 dB/km

3 dB/km

3 dB/km

  • ? at 38.4 kHz maximum

4 dB/km

4 dB/km

4 dB/km

4 dB/km

  • ? at 4 MHz maximum

22 dB/km

25 dB/km

25 dB/km

25 dB/km

  • ? at 16 MHz maximum

42 dB/km

49 dB/km

49 dB/km

49 dB/km

Impedance

 

 

 

 

  • ? Rated value

150 ?

150 ?

150 ?

150 ?

  • ? at 9.6 kHz

270 ?

270 ?

270 ?

270 ?

  • ? at 38.4 kHz

185 ?

185 ?

185 ?

185 ?

  • ? at 3 MHz … 20 MHz

150 ?

150 ?

150 ?

150 ?

Relative symmetrical tolerance

 

 

 

 

  • ? of the characteristic impedance at 9.6 kHz

10 %

10 %

10 %

10 %

  • ? of the characteristic impedance at 38.4 kHz

10 %

10 %

10 %

10 %

  • ? of the characteristic impedance at 3 MHz … 20 MHz

10 %

10 %

10 %

10 %

Loop resistance per length maximum

110 m?/m

133 m?/m

133 m?/m

133 m?/m

Shield resistance per length maximum

9.5 ?/km

15 ?/km

14 ?/km

14 ?/km

Insulation resistance coefficient

16 000 G?·m

Capacity per length at 1 kHz

28.5 pF/m

28 pF/m

28 pF/m

28 pF/m

Operating voltage

 

 

 

 

  • ? RMS value

80 V

80 V

80 V

80 V

Mechanical data

 

 

 

 

Number of electrical cores

2

2

2

2

Design of the shield

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Type of electrical connection FastConnect

Yes

Yes

Yes

Yes

Outer diameter

 

 

 

 

  • ? of inner conductor

0.65 mm

0.67 mm

0.67 mm

0.67 mm

  • ? of the wire insulation

2.55 mm

2.56 mm

2.56 mm

2.56 mm

  • ? of the inner sheath of the cable

5.4 mm

5.4 mm

5.4 mm

5.4 mm

  • ? of cable sheath

10.8 mm

8 mm

8 mm

8 mm

  • ? of cable sheath Note

The cable (diameter 8.0 mm +-0.4 mm) has an additional black outer cover (diameter 10.8 mm +-0.5 mm) as protection against damage if laid in the ground. because of outer diameter > 8 mm: Bus connectors can only be connected after removing the outer cover.

Symmetrical tolerance of the outer diameter of cable sheath

0.5 mm

0.4 mm

0.4 mm

0.4 mm

Material

 

 

 

 

  • ? of the wire insulation

PE

PE

PE

PE

  • ? of the inner sheath of the cable

PVC

FRNC

PVC

PVC

  • ? of cable sheath

PE/PVC; PVC (sheath of the cable), PE (additional outer sheath)

PUR (TPE-U)

PUR (TPE-U)

PUR (TPE-U)

Color

 

 

 

 

  • ? of the insulation of data wires

red/green

red/green

red/green

red/green

  • ? of cable sheath

Black

Violet

petrol

Violet

Bending radius

 

 

 

 

  • ? with single bend minimum permissible

41 mm

40 mm

40 mm

40 mm

  • ? with multiple bends minimum permissible

81 mm

120 mm

  • ? with continuous bending

120 mm

120 mm

Number of bending cycles

3 000 000; Drag chain suitable for 3 million bending cycles at a bending radius of 120 mm (15x D), a speed of 4 m/s and an acceleration of 4 m/s?

3 000 000; Drag chain suitable for 3 million bending cycles at a bending radius of 120 mm (15x D) and an acceleration of 4 m/s?

Tensile load maximum

100 N

100 N

100 N

100 N

Weight per length

117 kg/km

70 kg/km

77 kg/km

77 kg/km

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-40 ... +60 °C

-20 ... +60 °C

-40 ... +60 °C

-40 ... +60 °C

  • ? during storage

-40 ... +60 °C

-40 ... +60 °C

-40 ... +60 °C

-40 ... +60 °C

  • ? during transport

-40 ... +60 °C

-40 ... +60 °C

-40 ... +60 °C

-40 ... +60 °C

  • ? during installation

-40 ... +60 °C

-40 ... +60 °C

-40 ... +60 °C

-40 ... +60 °C

  • ? Note

Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472

Ambient condition for operation

Limited segment length (see manual for PROFIBUS networks)

Limited segment length (see manual for PROFIBUS networks)

Limited segment length (see manual for PROFIBUS networks)

Burning behavior

inflammable

flame resistant according to IEC 60332-1-2

flame resistant according to IEC 60332-1-2

flame resistant according to IEC 60332-1-2

Chemical resistance

 

 

 

 

  • ? to mineral oil

oil resistant according to IEC 60811-2-1 (4 hours / 70°C)

oil resistant according to IEC 60811-2-1 (7x24h/90°C)

oil resistant according to IEC 60811-2-1 (7x24h/90°C)

oil resistant according to IEC 60811-2-1 (7x24h/90°C)

  • ? to grease

Conditional resistance

resistant

resistant

resistant

  • ? to water

conditional resistance

conditional resistance

conditional resistance

conditional resistance

Radiological resistance to UV radiation

resistant / Sunlight resistant acc. to UL 444 Sec. 7.12

resistant

resistant

resistant

Product properties, functions, components general

 

 

 

 

Product feature

 

 

 

 

  • ? halogen-free

No

Yes

No

No

  • ? silicon-free

Yes

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

 

UL/ETL listing 300 V Rating

No

Yes; c(UL)us, CMX

Yes; c(UL)us, CMX

Yes; CMX

UL/ETL style 600 V Rating

No

No

No

No

Certificate of suitability

CE, FCC, IC, cULus, Ex approval only together with 6GT2801-4AB10

  • ? CE marking

Yes

Yes

Yes

Yes

  • ? RoHS conformity

Yes

Yes

Yes

Yes

Marine classification association

 

 

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

No

No

No

No

  • ? Bureau Veritas (BV)

No

No

No

No

  • ? Det Norske Veritas (DNV)

No

No

No

No

  • ? Germanische Lloyd (GL)

No

No

No

No

  • ? Lloyds Register of Shipping (LRS)

No

No

No

No

  • ? Nippon Kaiji Kyokai (NK)

No

No

No

No

  • ? Polski Rejestr Statkow (PRS)

No

No

No

No


Order number

6XV1830-0LH10

6XV1830-3GH10

6XV1830-0PH10

6XV1830-0MH10

Product type designation

PROFIBUS FC FRNC Cable GP

PROFIBUS Festoon Cable GP

PROFIBUS Torsion Cable

SIENOPYR FR ship cable

Product description

Flame retardant, halogen-free bus cable (2-core), sold by the meter, unassembled

Flexible bus cable (2-core), sold by the meter, unassembled

Highly flexible bus cable (2-core), sold by the meter, unassembled

Bus cable (2-core), sold by the meter, unassembled

Suitability for use

Halogen-free cable, suitable for use in buildings

Specially for festoon attachment

For use in moving machine components

Cable for fixed installation on ships and offshore facilities in all enclosed spaces and on open decks. This cable cannot be used for permanent installation in water.

Cable designation

02YSH (ST) CH 1x2x0,64/2,55-150 VI KF 25 FRNC FC

02YS (ST) CY 1 x 2 x 0,65/2,56 LI petrol FR

02Y (ST) C 11Y 1x2x0,8/2,56-150 LI FR VI

M-02Y (ST) CH X 1 x 2 x 0,35 100 V

Electrical data

 

 

 

 

Damping ratio per length

 

 

 

 

  • ? at 9.6 kHz maximum

2.5 dB/km

3 dB/km

2.5 dB/km

3 dB/km

  • ? at 38.4 kHz maximum

4 dB/km

4 dB/km

3 dB/km

5 dB/km

  • ? at 4 MHz maximum

22 dB/km

25 dB/km

25 dB/km

22 dB/km

  • ? at 16 MHz maximum

42 dB/km

49 dB/km

49 dB/km

45 dB/km

Impedance

 

 

 

 

  • ? Rated value

150 ?

150 ?

150 ?

150 ?

  • ? at 9.6 kHz

270 ?

270 ?

270 ?

250 ?

  • ? at 38.4 kHz

185 ?

185 ?

185 ?

185 ?

  • ? at 3 MHz … 20 MHz

150 ?

150 ?

150 ?

150 ?

Relative symmetrical tolerance

 

 

 

 

  • ? of the characteristic impedance at 9.6 kHz

10 %

10 %

10 %

10 %

  • ? of the characteristic impedance at 38.4 kHz

10 %

10 %

10 %

10 %

  • ? of the characteristic impedance at 3 MHz … 20 MHz

10 %

10 %

10 %

10 %

Loop resistance per length maximum

110 m?/m

133 m?/m

98 m?/m

110 m?/m

Shield resistance per length maximum

9.5 ?/km

19 ?/km

14 ?/km

Insulation resistance coefficient

16 000 G?·m

16 000 G?·m

16 000 G?·m

Capacity per length at 1 kHz

28.5 pF/m

28 pF/m

29 pF/m

Operating voltage

 

 

 

 

  • ? RMS value

80 V

80 V

80 V

100 V

Mechanical data

 

 

 

 

Number of electrical cores

2

2

2

2

Design of the shield

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Type of electrical connection FastConnect

Yes

No

No

No

Outer diameter

 

 

 

 

  • ? of inner conductor

0.65 mm

0.67 mm

0.8 mm

0.67 mm

  • ? of the wire insulation

2.55 mm

2.56 mm

2.56 mm

  • ? of the inner sheath of the cable

5.4 mm

5.8 mm

6 mm

8 mm

  • ? of cable sheath

8 mm

8 mm

8 mm

9.8 mm

  • ? of cable sheath Note

Outer diameter > 8 mm: Bus connectors can only be connected after removing the outer cover

Symmetrical tolerance of the outer diameter of cable sheath

0.4 mm

0.3 mm

0.4 mm

0.5 mm

Material

 

 

 

 

  • ? of the wire insulation

PE

PE

PE

PE

  • ? of the inner sheath of the cable

FRNC

Halogen-free polymer (HM4)

  • ? of cable sheath

FRNC

PVC

PUR (TPE-U)

Halogen-free, cross-linked polymer

Color

 

 

 

 

  • ? of the insulation of data wires

red/green

red/green

red/green

red/green

  • ? of cable sheath

Violet

petrol

Violet

Black

Bending radius

 

 

 

 

  • ? with single bend minimum permissible

60 mm

30 mm

30 mm

98 mm

  • ? with multiple bends minimum permissible

80 mm

196 mm

  • ? with continuous bending

70 mm

60 mm

Number of bending cycles

Not suitable for garland usage

Number of torsion cycles with torsion by ± 180° on 1 m cable length

5 000 000

Tensile load maximum

100 N

80 N

100 N

100 N

Weight per length

72 kg/km

64 kg/km

65 kg/km

110 kg/km

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-25 ... +80 °C

-40 ... +80 °C

-25 ... +75 °C

-35 ... +80 °C

  • ? during storage

-25 ... +80 °C

-40 ... +80 °C

-40 ... +80 °C

-35 ... +80 °C

  • ? during transport

-25 ... +80 °C

-40 ... +80 °C

-40 ... +80 °C

-35 ... +80 °C

  • ? during installation

-25 ... +80 °C

-40 ... +80 °C

-25 ... +75 °C

-15 ... +80 °C

  • ? Note

Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472

Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472

Ambient condition for operation

At ambient temperatures below -15 °C, the cable must not be subjected to any movements other than the normal vibration levels encountered on board ship

Burning behavior

flame resistant according to IEC 60332-3-24 (Category C), IEC 60332-3-22 (Category A), EN 50267-2-1/2, IEC 61034

flame resistant according to IEC 60332-3-24 (Category C)

flame resistant according to IEC 60332-1-2

flame resistant according to IEC 60332-3-24, IEC 607542, IEC 61031, DIN VDE 0472 Part 805 Prufart B

Chemical resistance

 

 

 

 

  • ? to mineral oil

oil resistant according to IEC 60811-2-1 (4 h / 70°C)

conditional resistance

oil resistant according to IEC 60811-2-1 (7x24h/90°C)

resistant to diesel fuel according to DIN VDE 51601, ASTM oil No. 2 according to DIN 53521, oil, NATOCode 0178, BWTL 91500031/2 according to VG 95214 Part 4, hydraulic fluid, NATOCode H515, BWTL 91500020 according to VG 95214 Part 4, cold cleaning solvent, BW-TL 68500017 according to VG 95214 Part 4, deionized water according to VG 95214 Part 4, deionized water with 3.5% NaCl

  • ? to grease

Conditional resistance

Conditional resistance

resistant

resistant

  • ? to water

conditional resistance

conditional resistance

conditional resistance

conditional resistance

Radiological resistance to UV radiation

resistant

resistant

resistant

resistant

Product properties, functions, components general

 

 

 

 

Product feature

 

 

 

 

  • ? halogen-free

Yes

No

Yes

Yes

  • ? silicon-free

Yes

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

 

UL/ETL listing 300 V Rating

Yes; c(UL)us, CM / CL3 / Sun Res

Yes; CMG / PLCT / Sun Res / Oil Res

Yes; CMX

No

UL/ETL style 600 V Rating

Yes

Yes

No

No

Certificate of suitability

  • ? CE marking

Yes

Yes

Yes

  • ? RoHS conformity

Yes

Yes

Marine classification association

 

 

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

No

No

No

No

  • ? Bureau Veritas (BV)

No

No

No

No

  • ? Det Norske Veritas (DNV)

No

No

No

Yes

  • ? Germanische Lloyd (GL)

No

No

No

Yes

  • ? Lloyds Register of Shipping (LRS)

No

No

No

Yes

  • ? Nippon Kaiji Kyokai (NK)

No

No

No

No

  • ? Polski Rejestr Statkow (PRS)

No

No

No

No


Order number

6XV1860-2R

6XV1860-2S

Product type designation

PROFIBUS Hybrid Standard Cable GP

PROFIBUS Hybrid Robust Cable

Product description

Hybrid cable (data and energy wires), product sold by meter, unassembled

Hybrid cable (data and energy wires), product sold by meter, unassembled

Suitability for use

Trailing-type, hybrid cable used for supplying data and power to ET 200pro

Rugged cable for supplying data and power to ET 200pro under conditions of high mechanical loading. Cable resistance to weld spatter according to HD22.2 S3 / 5

Cable designation

02Y(ST)C 1x2x0.65/2.56-150LI LIY-Z Y 2x1x1.5 VI

02Y(ST)C 1x2x0.65/2.56-150LI LIH-Z 11Y 2x1x1.5 VI FRNC

Electrical data

 

 

Damping ratio per length

 

 

  • ? at 9.6 kHz maximum

4 dB/km

4 dB/km

  • ? at 38.4 kHz maximum

4 dB/km

4 dB/km

  • ? at 4 MHz maximum

25 dB/km

25 dB/km

  • ? at 16 MHz maximum

49 dB/km

49 dB/km

Impedance

 

 

  • ? Rated value

150 ?

150 ?

  • ? at 9.6 kHz

270 ?

270 ?

  • ? at 38.4 kHz

185 ?

185 ?

  • ? at 3 MHz … 20 MHz

150 ?

150 ?

Relative symmetrical tolerance

 

 

  • ? of the characteristic impedance at 9.6 kHz

10 %

10 %

  • ? of the characteristic impedance at 38.4 kHz

10 %

10 %

  • ? of the characteristic impedance at 3 MHz … 20 MHz

10 %

10 %

Loop resistance per length maximum

138 ?/km

138 ?/km

Shield resistance per length maximum

10 ?/km

10 ?/km

Insulation resistance coefficient

20 G?·m

Operating voltage maximum

80 V

80 V

Capacity per length at 1 kHz

30 pF/m

30 pF/m

Operating voltage RMS value

300 V

300 V

Conductor cross section of the power wire

1.5 mm?

1.5 mm?

Continuous current of the power wires

7.5 A

7.5 A

Mechanical data

 

 

Design of the shield

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Number of electrical cores

4

4

Type of electrical connection FastConnect

No

No

Outer diameter

 

 

  • ? of inner conductor

0.67 mm

0.67 mm

  • ? of the wire insulation

2.56 mm

2.56 mm

  • ? of cable sheath

11 mm

11 mm

Symmetrical tolerance of the outer diameter of cable sheath

0.5 mm

0.5 mm

Material

 

 

  • ? of the wire insulation

PE

PE

  • ? of cable sheath

PVC

PUR

Color

 

 

  • ? of the insulation of data wires

red / green

red / green

  • ? of the power wire insulation

Black

Black

  • ? of cable sheath

Violet

Violet

Bending radius

 

 

  • ? with single bend minimum permissible

44 mm

44 mm

  • ? with multiple bends minimum permissible

125 mm

125 mm

Number of bending cycles

1 000 000; For use in cable carriers, for 1 million bending cycles with a bending radius of 125 mm and an acceleration of 2.5 m/s?

3 000 000; For use in cable carriers, for 3 million bending cycles with a bending radius of 125 mm and an acceleration of 2.5 m/s?

Tensile load maximum

450 N

450 N

Weight per length

140 kg/km

135 kg/km

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • ? during operation

-40 ... +75 °C

-40 ... +75 °C

  • ? during storage

-40 ... +75 °C

-40 ... +75 °C

  • ? during transport

-40 ... +75 °C

-40 ... +75 °C

  • ? during installation

-40 ... +75 °C

-40 ... +75 °C

  • ? Note

Electrical properties measured at 20 Cel, verification according to DIN 47250 part 4 respectively DIN VDE 0490

Electrical properties measured at 20 Cel, verification according to DIN 47250 part 4 respectively DIN VDE 0490

Burning behavior

flame-retardant according to IEC 60332-1-2

flame-retardant according to IEC 60332-1-2

Chemical resistance

 

 

  • ? to mineral oil

Conditional resistance

Resistant

  • ? to grease

Conditional resistance

Resistant

Radiological resistance to UV radiation

not resistant

resistant

Product properties, functions, components general

 

 

Product feature

 

 

  • ? halogen-free

No

Yes

  • ? silicon-free

Yes

Yes

Standards, specifications, approvals

 

 

UL/ETL listing 300 V Rating

Yes; CMG

Yes; CMX

UL/ETL style 600 V Rating

No

No

Certificate of suitability

  • ? RoHS conformity

Yes

Yes


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ
Êàòàëîã îáîðóäîâàíèÿ 2017
Siemens Industry Catalog Drive Technology Automation Technology Automation Systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial Communication Introduction Industrial Ethernet PROFINET PROFIBUS Introduction Process or field communication Data communication Communication overview Configuration examples Topologies Network components for PROFIBUS Overview of network components Network selection criteria Connection examples Electrical networks (RS 485) PROFIBUS FastConnect PROFIBUS bus cables ECOFAST bus cables ECOFAST Hybrid Field Bus Connections Energy cables RS 485 bus connector 830-1T connecting cable 830-2 connecting cable PROFIBUS M12 and 7/8 connecting cable/connector Bus terminals Active RS 485 terminating element Repeater RS 485 for PROFIBUS Diagnostics repeater for PROFIBUS DP Electrical networks (PROFIBUS PA) Electrical networks (FOUNDATION Fieldbus) Optical networks with OLM Optical networks with OBT and integrated interface System Interfaces Network Transitions Industrial Controls Switching and Protection Devices for Power Distribution Power Monitoring SENTRON measuring devices Industrial identification systems Network management and diagnostics PROFIBUS components Partner Solutions AS-Interface IO-Link Industrial Wireless Communication Industrial Remote Communication Industrial Security Industrial Controls Manufacturing Execution Systems (MES) SIMATIC IT PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supplies Products for specific requirements Energy Building Technologies Low-Voltage Controls and Distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services ... and everything else you need




  © ÎÎÎ "ÑÊ ÝÍÅÐÃÎ" 2007-2022
  (4872) 700-366  skenergo@mail.ru
ßíäåêñ.Ìåòðèêà