SCALANCE XB-200 managed

Order number

6GK5208-0BA00-2AB2 1)

6GK5205-3BB00-2AB2 1)

Order number

6GK5208-0BA00-2TB2 2)

6GK5205-3BB00-2TB2 2)

Product type designation

SCALANCE XB208

SCALANCE XB205-3

Transmission rate

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

Interfaces

 

 

Number of electrical/optical connections

 

 

  • ? for network components or terminal equipment maximum

8

8

Number of electrical connections

 

 

  • ? for network components or terminal equipment

8

5

Type of electrical connection

 

 

  • ? for network components or terminal equipment

RJ45 port

RJ45 port

Number of optical interfaces

 

 

  • ? for fiber optic cable at 100 Mbit/s

3

Interfaces for communication integrated

 

 

Number of 100 Mbit/s ST(BFOC) ports

 

 

  • ? for multimode

3

Number of 100 Mbit/s SC ports

 

 

  • ? for multimode

0

0

Number of 1000 Mbit/s LC ports

 

 

  • ? for multimode

0

0

  • ? for single mode (LD)

0

0

Interfaces others

 

 

Number of electrical connections

 

 

  • ? for operator console

1

1

  • ? for management purposes

1

1

  • ? for power supply

1

1

  • ? for redundant voltage supply

1

1

Type of electrical connection

 

 

  • ? for operator console

RJ11 port

RJ11 port

  • ? for management purposes

RJ45 port

RJ45 port

  • ? for power supply

6-pole terminal block

6-pole terminal block

Supply voltage, current consumption, power loss

 

 

Type of voltage of the supply voltage

DC

DC

Supply voltage

 

 

  • ? external

24 V

24 V

  • ? external

19.2 ... 28.8 V

19.2 ... 28.8 V

Product component fusing at power supply input

Yes

Yes

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • ? during operation

-10 ... +60 °C

-10 ... +60 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

Relative humidity

 

 

  • ? at 25 °C without condensation during operation maximum

95 %

97 %

Protection class IP

IP20

IP22

Design, dimensions and weight

 

 

Design

compact

compact

Width

40 mm

80 mm

Height

117 mm

119 mm

Depth

109 mm

111 mm

Material of the enclosure

Plastic

Plastic

Mounting type

  • ? 35 mm DIN rail mounting

Yes

Yes

  • ? wall mounting

No

No

  • ? S7-300 rail mounting

No

No

  • ? S7-1500 rail mounting

No

No

Product properties, functions, components general

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

50

50

Cascading in cases of star topology

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functions management, configuration

 

 

Product function

 

 

  • ? CLI

Yes

Yes

  • ? web-based management

Yes

Yes

  • ? MIB support

Yes

Yes

  • ? TRAPs via email

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

  • ? RMON

Yes

Yes

  • ? Port mirroring

Yes

Yes

  • ? multiport mirroring

No

No

  • ? CoS

Yes

Yes

  • ? with IRT PROFINET IO switch

No

No

  • ? PROFINET IO diagnosis

Yes

Yes

  • ? switch-managed

Yes

Yes

Protocol is supported

 

 

  • ? Telnet

Yes

Yes

  • ? HTTP

Yes

Yes

  • ? HTTPS

Yes

Yes

  • ? TFTP

Yes

Yes

  • ? FTP

Yes

Yes

  • ? BOOTP

No

No

  • ? DCP

Yes

Yes

  • ? LLDP

Yes

Yes

  • ? EtherNet/IP

Yes

Yes

  • ? IGMP (snooping/querier)

Yes

Yes

Identification & maintenance function

 

 

  • ? I&M0 - device-specific information

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Protocol is supported

 

 

  • ? SNMP v1

Yes

Yes

  • ? SNMP v2

Yes

Yes

  • ? SNMP v3

Yes

Yes

Product functions Diagnosis

 

 

Product function

 

 

  • ? Port diagnostics

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

  • ? Statistics packet type

Yes

Yes

  • ? Error statistics

Yes

Yes

  • ? SysLog

Yes

Yes

  • ? loopback diagnostics

Yes

Yes

Product functions VLAN

 

 

Product function

 

 

  • ? VLAN - port based

Yes

Yes

  • ? VLAN - protocol-based

No

No

  • ? VLAN - IP-based

No

No

  • ? VLAN dynamic

No

No

Product functions DHCP

 

 

Product function

 

 

  • ? DHCP client

Yes

Yes

Product functions Redundancy

 

 

Product function

 

 

  • ? Ring redundancy

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

No

No

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Product function

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

  • ? redundancy procedure STP

Yes

Yes

  • ? redundancy procedure RSTP

Yes

Yes

  • ? redundancy procedure MSTP

Yes

Yes

  • ? Passive listening

Yes

Yes

Product functions Security

 

 

Product function

 

 

  • ? ACL - MAC-based

Yes

Yes

  • ? IEEE 802.1x (radius)

Yes

Yes

  • ? Broadcast/Multicast/Unicast Limiter

Yes

Yes

  • ? broadcast blocking

Yes

Yes

Protocol is supported

 

 

  • ? SSH

Yes

Yes

Product functions Time

 

 

Product function

 

 

  • ? SICLOCK support

Yes

Yes

Protocol is supported

 

 

  • ? NTP

Yes

Yes

  • ? SNTP

Yes

Yes

Standards, specifications, approvals

 

 

Standard

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T6

  • ? for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-3

  • ? for hazardous zone from CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T6

  • ? for emitted interference

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

  • ? for interference immunity

EN 61000-6-2

EN 61000-6-4

Certificate of suitability

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-6

  • ? CE marking

Yes

Yes

  • ? C-Tick

Yes

Yes

  • ? KC approval

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

No

  • ? Railway application in accordance with EN 50124-1

No

No

Marine classification association

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

No

No

  • ? Bureau Veritas (BV)

No

No

  • ? Det Norske Veritas (DNV)

No

No

  • ? Germanische Lloyd (GL)

No

No

  • ? Lloyds Register of Shipping (LRS)

No

No

  • ? Nippon Kaiji Kyokai (NK)

No

No

  • ? Polski Rejestr Statkow (PRS)

No

No

1) Preset for PROFINET mode!
2) Preset for Ethernet/IP mode!

Order number

6GK5205-3BD00-2AB2 1)

6GK5205-3BF00-2AB2 1)

Order number

6GK5205-3BD00-2TB2 2)

6GK5205-3BF00-2TB2 2)

Product type designation

SCALANCE XB205-3

SCALANCE XB205-3LD

Transmission rate

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

Interfaces

 

 

Number of electrical/optical connections

 

 

  • ? for network components or terminal equipment maximum

8

8

Number of electrical connections

 

 

  • ? for network components or terminal equipment

5

5

Type of electrical connection

 

 

  • ? for network components or terminal equipment

RJ45 port

RJ45 port

Number of optical interfaces

 

 

  • ? for fiber optic cable at 100 Mbit/s

3

3

Interfaces for communication integrated

 

 

Number of 100 Mbit/s SC ports

 

 

  • ? for multimode

0

0

Number of 1000 Mbit/s LC ports

 

 

  • ? for multimode

0

0

  • ? for single mode (LD)

0

0

Interfaces others

 

 

Number of electrical connections

 

 

  • ? for operator console

1

1

  • ? for management purposes

1

1

  • ? for power supply

1

1

  • ? for redundant voltage supply

1

1

Type of electrical connection

 

 

  • ? for operator console

RJ11 port

RJ11 port

  • ? for management purposes

RJ45 port

RJ45 port

  • ? for power supply

6-pole terminal block

6-pole terminal block

Supply voltage, current consumption, power loss

 

 

Type of voltage of the supply voltage

DC

DC

Supply voltage

 

 

  • ? external

24 V

24 V

  • ? external

19.2 ... 28.8 V

19.2 ... 28.8 V

Product component fusing at power supply input

Yes

Yes

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • ? during operation

-10 ... +60 °C

-10 ... +60 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

Relative humidity

 

 

  • ? at 25 °C without condensation during operation maximum

96 %

98 %

Protection class IP

IP21

IP23

Design, dimensions and weight

 

 

Design

compact

compact

Width

80 mm

80 mm

Height

118 mm

120 mm

Depth

110 mm

112 mm

Material of the enclosure

Plastic

Plastic

Mounting type

  • ? 35 mm DIN rail mounting

Yes

Yes

  • ? wall mounting

No

No

  • ? S7-300 rail mounting

No

No

  • ? S7-1500 rail mounting

No

No

Product properties, functions, components general

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

50

50

Cascading in cases of star topology

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functions management, configuration

 

 

Product function

 

 

  • ? CLI

Yes

Yes

  • ? web-based management

Yes

Yes

  • ? MIB support

Yes

Yes

  • ? TRAPs via email

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

  • ? RMON

Yes

Yes

  • ? Port mirroring

Yes

Yes

  • ? multiport mirroring

No

No

  • ? CoS

Yes

Yes

  • ? with IRT PROFINET IO switch

No

No

  • ? PROFINET IO diagnosis

Yes

Yes

  • ? switch-managed

Yes

Yes

Protocol is supported

 

 

  • ? Telnet

Yes

Yes

  • ? HTTP

Yes

Yes

  • ? HTTPS

Yes

Yes

  • ? TFTP

Yes

Yes

  • ? FTP

Yes

Yes

  • ? BOOTP

No

No

  • ? DCP

Yes

Yes

  • ? LLDP

Yes

Yes

  • ? EtherNet/IP

Yes

Yes

  • ? IGMP (snooping/querier)

Yes

Yes

Identification & maintenance function

 

 

  • ? I&M0 - device-specific information

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Protocol is supported

 

 

  • ? SNMP v1

Yes

Yes

  • ? SNMP v2

Yes

Yes

  • ? SNMP v3

Yes

Yes

Product functions Diagnosis

 

 

Product function

 

 

  • ? Port diagnostics

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

  • ? Statistics packet type

Yes

Yes

  • ? Error statistics

Yes

Yes

  • ? SysLog

Yes

Yes

  • ? loopback diagnostics

Yes

Yes

Product functions VLAN

 

 

Product function

 

 

  • ? VLAN - port based

Yes

Yes

  • ? VLAN - protocol-based

No

No

  • ? VLAN - IP-based

No

No

  • ? VLAN dynamic

No

No

Product functions DHCP

 

 

Product function

 

 

  • ? DHCP client

Yes

Yes

Product functions Redundancy

 

 

Product function

 

 

  • ? Ring redundancy

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

No

No

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Product function

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

  • ? redundancy procedure STP

Yes

Yes

  • ? redundancy procedure RSTP

Yes

Yes

  • ? redundancy procedure MSTP

Yes

Yes

  • ? Passive listening

Yes

Yes

Product functions Security

 

 

Product function

 

 

  • ? ACL - MAC-based

Yes

Yes

  • ? IEEE 802.1x (radius)

Yes

Yes

  • ? Broadcast/Multicast/Unicast Limiter

Yes

Yes

  • ? broadcast blocking

Yes

Yes

Protocol is supported

 

 

  • ? SSH

Yes

Yes

Product functions Time

 

 

Product function

 

 

  • ? SICLOCK support

Yes

Yes

Protocol is supported

 

 

  • ? NTP

Yes

Yes

  • ? SNTP

Yes

Yes

Standards, specifications, approvals

 

 

Standard

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T5

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T7

  • ? for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-2

UL 60950-1, CSA C22.2 No. 60950-4

  • ? for hazardous zone from CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T5

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T7

  • ? for emitted interference

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

  • ? for interference immunity

EN 61000-6-3

EN 61000-6-5

Certificate of suitability

EN 61000-6-2, EN 61000-6-5

EN 61000-6-2, EN 61000-6-7

  • ? CE marking

Yes

Yes

  • ? C-Tick

Yes

Yes

  • ? KC approval

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

No

  • ? Railway application in accordance with EN 50124-1

No

No

Marine classification association

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

No

No

  • ? Bureau Veritas (BV)

No

No

  • ? Det Norske Veritas (DNV)

No

No

  • ? Germanische Lloyd (GL)

No

No

  • ? Lloyds Register of Shipping (LRS)

No

No

  • ? Nippon Kaiji Kyokai (NK)

No

No

  • ? Polski Rejestr Statkow (PRS)

No

No

1) Preset for PROFINET mode!
2) Preset for Ethernet/IP mode!

Order number

6GK5216-0BA00-2AB2 1)

6GK5213-3BB00-2AB2 1)

Order number

6GK5216-0BA00-2TB2 2)

6GK5213-3BB00-2TB2 2)

Product type designation

SCALANCE XB216

SCALANCE XB213-3

Transmission rate

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

Interfaces

 

 

Number of electrical/optical connections

 

 

  • ? for network components or terminal equipment maximum

16

16

Number of electrical connections

 

 

  • ? for network components or terminal equipment

16

13

Type of electrical connection

 

 

  • ? for network components or terminal equipment

RJ45 port

RJ45 port

Number of optical interfaces

 

 

  • ? for fiber optic cable at 100 Mbit/s

3

Interfaces for communication integrated

 

 

Number of 100 Mbit/s ST(BFOC) ports

 

 

  • ? for multimode

3

Number of 100 Mbit/s SC ports

 

 

  • ? for multimode

0

0

Number of 1000 Mbit/s LC ports

 

 

  • ? for multimode

0

0

  • ? for single mode (LD)

0

0

Interfaces others

 

 

Number of electrical connections

 

 

  • ? for operator console

1

1

  • ? for management purposes

1

1

  • ? for power supply

1

1

  • ? for redundant voltage supply

1

1

Type of electrical connection

 

 

  • ? for operator console

RJ11 port

RJ11 port

  • ? for management purposes

RJ45 port

RJ45 port

  • ? for power supply

6-pole terminal block

6-pole terminal block

Supply voltage, current consumption, power loss

 

 

Type of voltage of the supply voltage

DC

DC

Supply voltage

 

 

  • ? external

24 V

24 V

  • ? external

19.2 ... 28.8 V

19.2 ... 28.8 V

Product component fusing at power supply input

Yes

Yes

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • ? during operation

-10 ... +60 °C

-10 ... +60 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

Relative humidity

 

 

  • ? at 25 °C without condensation during operation maximum

95 %

95 %

Protection class IP

IP24

IP26

Design, dimensions and weight

 

 

Design

compact

compact

Width

80 mm

120 mm

Height

121 mm

123 mm

Depth

113 mm

115 mm

Material of the enclosure

Plastic

Plastic

Mounting type

  • ? 35 mm DIN rail mounting

Yes

Yes

  • ? wall mounting

No

No

  • ? S7-300 rail mounting

No

No

  • ? S7-1500 rail mounting

No

No

Product properties, functions, components general

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

50

50

Cascading in cases of star topology

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functions management, configuration

 

 

Product function

 

 

  • ? CLI

Yes

Yes

  • ? web-based management

Yes

Yes

  • ? MIB support

Yes

Yes

  • ? TRAPs via email

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

  • ? RMON

Yes

Yes

  • ? Port mirroring

Yes

Yes

  • ? multiport mirroring

No

No

  • ? CoS

Yes

Yes

  • ? with IRT PROFINET IO switch

No

No

  • ? PROFINET IO diagnosis

Yes

Yes

  • ? switch-managed

Yes

Yes

Protocol is supported

 

 

  • ? Telnet

Yes

Yes

  • ? HTTP

Yes

Yes

  • ? HTTPS

Yes

Yes

  • ? TFTP

Yes

Yes

  • ? FTP

Yes

Yes

  • ? BOOTP

No

No

  • ? DCP

Yes

Yes

  • ? LLDP

Yes

Yes

  • ? EtherNet/IP

Yes

Yes

  • ? IGMP (snooping/querier)

Yes

Yes

Identification & maintenance function

 

 

  • ? I&M0 - device-specific information

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Protocol is supported

 

 

  • ? SNMP v1

Yes

Yes

  • ? SNMP v2

Yes

Yes

  • ? SNMP v3

Yes

Yes

Product functions Diagnosis

 

 

Product function

 

 

  • ? Port diagnostics

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

  • ? Statistics packet type

Yes

Yes

  • ? Error statistics

Yes

Yes

  • ? SysLog

Yes

Yes

  • ? loopback diagnostics

Yes

Yes

Product functions VLAN

 

 

Product function

 

 

  • ? VLAN - port based

Yes

Yes

  • ? VLAN - protocol-based

No

No

  • ? VLAN - IP-based

No

No

  • ? VLAN dynamic

No

No

Product functions DHCP

 

 

Product function

 

 

  • ? DHCP client

Yes

Yes

Product functions Redundancy

 

 

Product function

 

 

  • ? Ring redundancy

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

No

No

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Product function

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

  • ? redundancy procedure STP

Yes

Yes

  • ? redundancy procedure RSTP

Yes

Yes

  • ? redundancy procedure MSTP

Yes

Yes

  • ? Passive listening

Yes

Yes

Product functions Security

 

 

Product function

 

 

  • ? ACL - MAC-based

Yes

Yes

  • ? IEEE 802.1x (radius)

Yes

Yes

  • ? Broadcast/Multicast/Unicast Limiter

Yes

Yes

  • ? broadcast blocking

Yes

Yes

Protocol is supported

 

 

  • ? SSH

Yes

Yes

Product functions Time

 

 

Product function

 

 

  • ? SICLOCK support

Yes

Yes

Protocol is supported

 

 

  • ? NTP

Yes

Yes

  • ? SNTP

Yes

Yes

Standards, specifications, approvals

 

 

Standard

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T8

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T10

  • ? for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-5

UL 60950-1, CSA C22.2 No. 60950-7

  • ? for hazardous zone from CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T8

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T10

  • ? for emitted interference

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

  • ? for interference immunity

EN 61000-6-6

EN 61000-6-8

Certificate of suitability

EN 61000-6-2, EN 61000-6-8

EN 61000-6-2, EN 61000-6-10

  • ? CE marking

Yes

Yes

  • ? C-Tick

Yes

Yes

  • ? KC approval

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

No

  • ? Railway application in accordance with EN 50124-1

No

No

Marine classification association

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

No

No

  • ? Bureau Veritas (BV)

No

No

  • ? Det Norske Veritas (DNV)

No

No

  • ? Germanische Lloyd (GL)

No

No

  • ? Lloyds Register of Shipping (LRS)

No

No

  • ? Nippon Kaiji Kyokai (NK)

No

No

  • ? Polski Rejestr Statkow (PRS)

No

No

1) Preset for PROFINET mode!
2) Preset for Ethernet/IP mode!

Order number

6GK5213-3BD00-2AB2 1)

6GK5213-3BF00-2AB2 1)

Order number

6GK5213-3BD00-2TB2 2)

6GK5213-3BF00-2TB2 2)

Product type designation

SCALANCE XB213-3

SCALANCE XB213-3LD

Transmission rate

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

Interfaces

 

 

Number of electrical/optical connections

 

 

  • ? for network components or terminal equipment maximum

16

16

Number of electrical connections

 

 

  • ? for network components or terminal equipment

13

13

Type of electrical connection

 

 

  • ? for network components or terminal equipment

RJ45 port

RJ45 port

Number of optical interfaces

 

 

  • ? for fiber optic cable at 100 Mbit/s

3

3

Interfaces for communication integrated

 

 

Number of 100 Mbit/s SC ports

 

 

  • ? for multimode

0

0

Number of 1000 Mbit/s LC ports

 

 

  • ? for multimode

0

0

  • ? for single mode (LD)

0

0

Interfaces others

 

 

Number of electrical connections

 

 

  • ? for operator console

1

1

  • ? for management purposes

1

1

  • ? for power supply

1

1

  • ? for redundant voltage supply

1

1

Type of electrical connection

 

 

  • ? for operator console

RJ11 port

RJ11 port

  • ? for management purposes

RJ45 port

RJ45 port

  • ? for power supply

6-pole terminal block

6-pole terminal block

Supply voltage, current consumption, power loss

 

 

Type of voltage of the supply voltage

DC

DC

Supply voltage

 

 

  • ? external

24 V

24 V

  • ? external

19.2 ... 28.8 V

19.2 ... 28.8 V

Product component fusing at power supply input

Yes

Yes

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • ? during operation

-10 ... +60 °C

-10 ... +60 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

Relative humidity

 

 

  • ? at 25 °C without condensation during operation maximum

95 %

95 %

Protection class IP

IP25

IP27

Design, dimensions and weight

 

 

Design

compact

compact

Width

120 mm

120 mm

Height

122 mm

124 mm

Depth

114 mm

116 mm

Material of the enclosure

Plastic

Plastic

Mounting type

  • ? 35 mm DIN rail mounting

Yes

Yes

  • ? wall mounting

No

No

  • ? S7-300 rail mounting

No

No

  • ? S7-1500 rail mounting

No

No

Product properties, functions, components general

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

50

50

Cascading in cases of star topology

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functions management, configuration

 

 

Product function

 

 

  • ? CLI

Yes

Yes

  • ? web-based management

Yes

Yes

  • ? MIB support

Yes

Yes

  • ? TRAPs via email

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

  • ? RMON

Yes

Yes

  • ? Port mirroring

Yes

Yes

  • ? multiport mirroring

No

No

  • ? CoS

Yes

Yes

  • ? with IRT PROFINET IO switch

No

No

  • ? PROFINET IO diagnosis

Yes

Yes

  • ? switch-managed

Yes

Yes

Protocol is supported

 

 

  • ? Telnet

Yes

Yes

  • ? HTTP

Yes

Yes

  • ? HTTPS

Yes

Yes

  • ? TFTP

Yes

Yes

  • ? FTP

Yes

Yes

  • ? BOOTP

No

No

  • ? DCP

Yes

Yes

  • ? LLDP

Yes

Yes

  • ? EtherNet/IP

Yes

Yes

  • ? IGMP (snooping/querier)

Yes

Yes

Identification & maintenance function

 

 

  • ? I&M0 - device-specific information

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Protocol is supported

 

 

  • ? SNMP v1

Yes

Yes

  • ? SNMP v2

Yes

Yes

  • ? SNMP v3

Yes

Yes

Product functions Diagnosis

 

 

Product function

 

 

  • ? Port diagnostics

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

  • ? Statistics packet type

Yes

Yes

  • ? Error statistics

Yes

Yes

  • ? SysLog

Yes

Yes

  • ? loopback diagnostics

Yes

Yes

Product functions VLAN

 

 

Product function

 

 

  • ? VLAN - port based

Yes

Yes

  • ? VLAN - protocol-based

No

No

  • ? VLAN - IP-based

No

No

  • ? VLAN dynamic

No

No

Product functions DHCP

 

 

Product function

 

 

  • ? DHCP client

Yes

Yes

Product functions Redundancy

 

 

Product function

 

 

  • ? Ring redundancy

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

No

No

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Product function

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

  • ? redundancy procedure STP

Yes

Yes

  • ? redundancy procedure RSTP

Yes

Yes

  • ? redundancy procedure MSTP

Yes

Yes

  • ? Passive listening

Yes

Yes

Product functions Security

 

 

Product function

 

 

  • ? ACL - MAC-based

Yes

Yes

  • ? IEEE 802.1x (radius)

Yes

Yes

  • ? Broadcast/Multicast/Unicast Limiter

Yes

Yes

  • ? broadcast blocking

Yes

Yes

Protocol is supported

 

 

  • ? SSH

Yes

Yes

Product functions Time

 

 

Product function

 

 

  • ? SICLOCK support

Yes

Yes

Protocol is supported

 

 

  • ? NTP

Yes

Yes

  • ? SNTP

Yes

Yes

Standards, specifications, approvals

 

 

Standard

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T9

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T11

  • ? for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-6

UL 60950-1, CSA C22.2 No. 60950-8

  • ? for hazardous zone from CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T9

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T11

  • ? for emitted interference

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

  • ? for interference immunity

EN 61000-6-7

EN 61000-6-9

Certificate of suitability

EN 61000-6-2, EN 61000-6-9

EN 61000-6-2, EN 61000-6-11

  • ? CE marking

Yes

Yes

  • ? C-Tick

Yes

Yes

  • ? KC approval

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

No

  • ? Railway application in accordance with EN 50124-1

No

No

Marine classification association

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

No

No

  • ? Bureau Veritas (BV)

No

No

  • ? Det Norske Veritas (DNV)

No

No

  • ? Germanische Lloyd (GL)

No

No

  • ? Lloyds Register of Shipping (LRS)

No

No

  • ? Nippon Kaiji Kyokai (NK)

No

No

  • ? Polski Rejestr Statkow (PRS)

No

No

1) Preset for PROFINET mode!
2) Preset for Ethernet/IP mode!

















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2016
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Введение Industrial Ethernet Введение Передача данных Обзор коммуникаций Топологии Критерии выбора типа сети Сетевые компоненты для Industrial Ethernet Промышленные конверторы каналов связи Industrial Ethernet коммутаторы Обзор Компактные коммутаторы CSM Неуправляемые коммутаторы SCALANCE X-000 Неуправляемые коммутаторы/конверторы SCALANCE X-100 Управляемые коммутаторы SCALANCE X-200 Управляемые коммутаторы SCALANCE X-200 Управляемые коммутаторы SIPLUS SCALANCE X-200 SCALANCE X-200PRO managed SCALANCE XB-200 managed Управляемые коммутаторы SCALANCE XF-200 Управляемая точка доступа SCALANCE X204RNA HSR Управляемые коммутаторы SCALANCE X-200IRT Управляемые коммутаторы SCALANCE X-300 RUGGEDCOM i800 unmanaged or managed RUGGEDCOM RS900 / M900 managed RUGGEDCOM RS950 RNA managed RUGGEDCOM RSG2xxx RUGGEDCOM RSG2100 / M2100 managed RUGGEDCOM RSG2200 / M2200 managed RUGGEDCOM RSG2300 managed RUGGEDCOM RSG2488 managed RUGGEDCOM RS1600 managed RUGGEDCOM RS8000 managed RUGGEDCOM Accessories RUGGEDCOM Technology Modules Коммутаторы Industrial Ethernet уровня 3/ маршрутизаторы Serial Device Servers Аксессуары Активные сетевые компоненты Безопасность передачи данных в промышленных сетях Системные интерфейсы Аксессуары RUGGEDCOM Accessories Управление сетью Сетевые переходы Обслуживание промышленных сетей Решения партнеров PROFINET PROFIBUS AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Информационная безопасность в промышленности Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация и безопасность зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо




  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика