Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2016
архивный
(4872) 700-366
skenergo@mail.ru

1- and 2-phase, 24 V DC

Order number

6EP1333-3BA10

6EP1333-3BA10-8AC0

6EP1334-3BA10

6EP1334-3BA10-8AB0

Product

SITOP PSU200M

SITOP PSU200M

SITOP PSU200M

SITOP PSU200M

Power supply, type

24 V/5 A

24 V/5 A

24 V/10 A

24 V/10 A

Input

 

 

 

 

Input

1-phase and 2-phase AC

1-phase and 2-phase AC

1-phase and 2-phase AC

1-phase and 2-phase AC

Supply voltage

 

 

 

 

  • ? 1 with AC

120 ... 230 V

120 ... 230 V

120 ... 230 V

120 ... 230 V

  • ? 2 with AC

230 ... 500 V

230 ... 500 V

230 ... 500 V

230 ... 500 V

  • ? Note

Set by means of selector switch on the device; starting from Vin > 90/180 V

Set by means of selector switch on the device; starting from Vin > 90/180 V

Set by means of selector switch on the device

Set by means of selector switch on the device

Input voltage

 

 

 

 

  • ? 1 with AC

85 ... 264 V

85 ... 264 V

85 ... 264 V

85 ... 264 V

  • ? 2 with AC

176 ... 550 V

176 ... 550 V

176 ... 550 V

176 ... 550 V

Wide-range input

Yes

Yes

Yes

Yes

Overvoltage resistance

1300 Vpeak, 1.3 ms

1300 Vpeak, 1.3 ms

1300 Vpeak, 1.3 ms

1300 Vpeak, 1.3 ms

Mains buffering at Iout rated, min.

25 ms; at Vin = 120/230 V, typ. 150 ms at Vin = 400 V

25 ms; at Vin = 120/230 V, typ. 150 ms at Vin = 400 V

25 ms; at Vin = 120/230 V, typ. 150 ms at Vin = 400 V

25 ms; at Vin = 120/230 V, typ. 150 ms at Vin = 400 V

Rated line frequency

50 ... 60 Hz

50 ... 60 Hz

50 ... 60 Hz

50 ... 60 Hz

Rated line range

47 ... 63 Hz

47 ... 63 Hz

47 ... 63 Hz

47 ... 63 Hz

Input current

 

 

 

 

  • ? at rated input voltage 120 V

2.2 A

2.2 A

4.4 A

4.4 A

  • ? at rated input voltage 230 V

1.2 A

1.2 A

2.4 A

2.4 A

  • ? at rated input voltage 500 V

0.61 A

0.61 A

1.1 A

1.1 A

Switch-on current limiting (+25 °C), max.

35 A

35 A

35 A

35 A

I?t, max.

1.7 A?·s

1.7 A?·s

4 A?·s

4 A?·s

Built-in incoming fuse

T 3.15 A (not accessible)

T 3.15 A (not accessible)

T 6.3 A (not accessible)

T 6.3 A (not accessible)

Protection in the mains power input (IEC 898)

Recommended miniature circuit breaker at 1-phase operation: from 6 A (10 A) characteristic C (B); required at 2-phase operation: circuit breaker 2-pole connected or circuit breaker 3RV2011-1EA10 (setting 3.8 A) or 3RV2711-1ED10 (UL 489) at 230 V; 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489) at 400/500 V

Recommended miniature circuit breaker at 1-phase operation: from 6 A (10 A) characteristic C (B); required at 2-phase operation: circuit breaker 2-pole connected or circuit breaker 3RV2011-1EA10 (setting 3.8 A) or 3RV2711-1ED10 (UL 489) at 230 V; 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489) at 400/500 V

Recommended miniature circuit breaker at 1-phase operation: from 6 A (10 A) characteristic C (B); required at 2-phase operation: circuit breaker 2-pole connected or circuit breaker 3RV2011-1EA10 (setting 3.8 A) or 3RV2711-1ED10 (UL 489) at 230 V; 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489) at 400/500 V

Recommended miniature circuit breaker at 1-phase operation: from 6 A (10 A) characteristic C (B); required at 2-phase operation: circuit breaker 2-pole connected or circuit breaker 3RV2011-1EA10 (setting 3.8 A) or 3RV2711-1ED10 (UL 489) at 230 V; 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489) at 400/500 V

Output

 

 

 

 

Output

Controlled, isolated DC voltage

Controlled, isolated DC voltage

Controlled, isolated DC voltage

Controlled, isolated DC voltage

Rated voltage Vout DC

24 V

24 V

24 V

24 V

Total tolerance, static ±

3 %

3 %

3 %

3 %

Static mains compensation, approx.

0.1 %

0.1 %

0.1 %

0.1 %

Static load balancing, approx.

0.1 %

0.1 %

0.1 %

0.1 %

Residual ripple peak-peak, max.

50 mV

50 mV

50 mV

50 mV

Spikes peak-peak, max. (bandwidth: 20 MHz)

200 mV

200 mV

200 mV

200 mV

Adjustment range

24 ... 28.8 V

24 ... 28.8 V

24 ... 28.8 V

24 ... 28.8 V

Product function Output voltage adjustable

Yes

Yes

Yes

Yes

Output voltage setting

via potentiometer

via potentiometer

via potentiometer

via potentiometer

Status display

Green LED for 24 V OK

Green LED for 24 V OK

Green LED for 24 V OK

Green LED for 24 V OK

Signaling

Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK"

Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK"

Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK"

Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK"

On/off behavior

Overshoot of Vout approx. 3 %

Overshoot of Vout approx. 3 %

Overshoot of Vout approx. 3 %

Overshoot of Vout approx. 3 %

Startup delay, max.

1 s

1 s

1 s

1 s

Voltage rise, typ.

50 ms

50 ms

50 ms

50 ms

Rated current value Iout rated

5 A

5 A

10 A

10 A

Current range

0 ... 5 A

0 ... 5 A

0 ... 10 A

0 ... 10 A

  • ? Note

+60 ... +70 °C: Derating 2%/K (at 120 V, 230 V) or 3.5%/K (at 400 V)

+60 ... +70 °C: Derating 2%/K (at 120 V, 230 V) or 3.5%/K (at 400 V)

Active power supplied typical

120 W

120 W

240 W

240 W

Short-term overload current

 

 

 

 

  • ? at short-circuit during operation typical

15 A

15 A

30 A

30 A

Duration of overloading capability for excess current

 

 

 

 

  • ? at short-circuit during operation

25 ms

25 ms

25 ms

25 ms

Constant overload current

 

 

 

 

  • ? on short-circuiting during the start-up typical

6 A

6 A

12 A

12 A

Parallel switching for enhanced performance

Yes; switchable characteristic

Yes; switchable characteristic

Yes; switchable characteristic

Yes; switchable characteristic

Numbers of parallel switchable units for enhanced performance

2

2

2

2

Efficiency

 

 

 

 

Efficiency at Vout rated, Iout rated, approx.

88 %

88 %

91 %

91 %

Power loss at Vout rated, Iout rated, approx.

17 W

17 W

24 W

24 W

Active power loss during no-load operation maximum

4 W

4 W

6 W

6 W

Closed-loop control

 

 

 

 

Dynamic mains compensation (Vin rated ±15 %), max.

0.1 %

0.1 %

0.1 %

0.1 %

Dynamic load smoothing (Iout: 50/100/50 %), Uout ± typ.

3 %

3 %

3 %

3 %

Load step setting time 50 to 100%, typ.

2 ms

2 ms

2 ms

2 ms

Load step setting time 100 to 50%, typ.

2 ms

2 ms

2 ms

2 ms

Setting time maximum

5 ms

5 ms

5 ms

5 ms

Protection and monitoring

 

 

 

 

Output overvoltage protection

< 35 V

< 35 V

< 35 V

< 35 V

Current limitation, typ.

6 A

6 A

12 A

12 A

Property of the output Short-circuit proof

Yes

Yes

Yes

Yes

Short-circuit protection

Alternatively, constant current characteristic approx. 5.5 A or latching shutdown

Alternatively, constant current characteristic approx. 5.5 A or latching shutdown

Alternatively, constant current characteristic approx. 12 A or latching shutdown

Alternatively, constant current characteristic approx. 12 A or latching shutdown

Enduring short circuit current RMS value

 

 

 

 

  • ? typical

6 A

6 A

12 A

12 A

Overload/short-circuit indicator

LED yellow for "overload", LED red for "latching shutdown"

LED yellow for "overload", LED red for "latching shutdown"

LED yellow for "overload", LED red for "latching shutdown"

LED yellow for "overload", LED red for "latching shutdown"

Safety

 

 

 

 

Primary/secondary isolation

Yes

Yes

Yes

Yes

Galvanic isolation

Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178

Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178

Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178

Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178

Protection class

Class I

Class I

Class I

Class I

Leakage current

 

 

 

 

  • ? maximum

3.5 mA

3.5 mA

3.5 mA

3.5 mA

  • ? typical

0.25 mA

0.25 mA

0.32 mA

0.32 mA

CE mark

Yes

Yes

Yes

Yes

UL/CSA approval

Yes

Yes

Yes

Yes

UL/cUL (CSA) approval

cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259

cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259

cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259

cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259

Explosion protection

ATEX (EX) II 3G Ex nA nC IIC T4 Gc (for AC 120-230/230-400 V); cCSAus (CSA C22.2 No. 213, ANSI/ISA-12.12.01) Class I, Div. 2, Group ABCD, T3

-

ATEX (EX) II 3G Ex nA nC IIC T4 Gc (for AC 120-230/230-400 V); cCSAus (CSA C22.2 No. 213, ANSI/ISA-12.12.01) Class I, Div. 2, Group ABCD, T3

-

Certificate of suitability IECEx

No

No

No

No

Certificate of suitability NEC Class 2

No

No

No

No

CB approval

Yes

Yes

Yes

Yes

Marine approval

GL, ABS

GL

GL, ABS

GL

Degree of protection (EN 60529)

IP20

IP20

IP20

IP20

EMC

 

 

 

 

Emitted interference

EN 55022 Class B

EN 55022 Class B

EN 55022 Class B

EN 55022 Class B

Supply harmonics limitation

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Noise immunity

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

Operating data

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-25 ... +70 °C

-25 ... +70 °C

-25 ... +70 °C

-25 ... +70 °C

  • Note

with natural convection

with natural convection

with natural convection

with natural convection

  • ? during transport

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

  • ? during storage

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

Humidity class according to EN 60721

Climate class 3K3, no condensation

Climate class 3K3, no condensation

Climate class 3K3, no condensation

Climate class 3K3, no condensation

Mechanics

 

 

 

 

Connection technology

screw-type terminals

screw-type terminals

screw-type terminals

screw-type terminals

Connections

 

 

 

 

  • ? Supply input

L, N, PE: 1 screw terminal each for 0.2 ... 2.5 mm? single-core/finely stranded

L, N, PE: 1 screw terminal each for 0.2 ... 2.5 mm? single-core/finely stranded

L, N, PE: 1 screw terminal each for 0.2 ... 2.5 mm? single-core/finely stranded

L, N, PE: 1 screw terminal each for 0.2 ... 2.5 mm? single-core/finely stranded

  • ? Output

+, -: 2 screw terminals each for 0.2 ... 2.5 mm?

+, -: 2 screw terminals each for 0.2 ... 2.5 mm?

+, -: 2 screw terminals each for 0.2 ... 2.5 mm?

+, -: 2 screw terminals each for 0.2 ... 2.5 mm?

  • ? Auxiliary

13, 14 (alarm signal): 1 screw terminal each for 0.14 ... 1.5 mm?

13, 14 (alarm signal): 1 screw terminal each for 0.14 ... 1.5 mm?

13, 14 (alarm signal): 1 screw terminal each for 0.14 ... 1.5 mm?

13, 14 (alarm signal): 1 screw terminal each for 0.14 ... 1.5 mm?

Width of the enclosure

70 mm

70 mm

70 mm

70 mm

Height of the enclosure

125 mm

125 mm

125 mm

125 mm

Depth of the enclosure

121 mm

121 mm

121 mm

121 mm

Weight, approx.

0.6 kg

0.6 kg

0.8 kg

0.8 kg

Product property of the enclosure housing for side-by-side mounting

Yes

Yes

Yes

Yes

Installation

Snaps onto DIN rail EN 60715 35x7.5/15

Snaps onto DIN rail EN 60715 35x7.5/15

Snaps onto DIN rail EN 60715 35x7.5/15

Snaps onto DIN rail EN 60715 35x7.5/15

Electrical accessories

Buffer module

Buffer module

Buffer module

Buffer module

Other information

Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)

Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)

Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)

Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2016
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Блоки питания SITOP Блоки питания серии SITOP lite SITOP compact Блоки питания серии SITOP compact Блоки питания серии LOGO!Power SITOP lite Блоки питания серии SITOP smart Модульные блоки питания SITOP 1-phase, 24 V DC 1- and 2-phase, 24 V DC 3-phase, 24 V DC 3-phase, 48 V DC SITOP modular, PSU8600 power supply system SITOP в исполнении SIMATIC Специальное исполнение и назначение Дополнительные компоненты Блоки бесперебойного питания DC-UPS Аксессуары Блоки питания заказного исполнения Семейство SIPLUS SIPLUS DC-UPS, бесперебойные источники питания Блоки питания для AS-интерфейса Техническая информация и проектирование SITOP power для AS-Interface Трансформаторы, источники питания и системы SIDAC Photovoltaics Продукты для специальных требований Автоматизация и безопасность зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо




  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика