SITOP UPS1100 Battery moduleProduct | SITOP UPS1100 battery module 24 V, 1.2 Ah | SITOP UPS1100 battery module 24 V, 3.2 Ah | SITOP UPS1100 battery module 24 V, 7 Ah | SITOP UPS1100 battery module 24 V, 12 Ah | SITOP UPS1100 battery module 24 V, 2.5 Ah high-temperature | For SITOP UPS1600 | 10 A | 10 A and 20 A | 10 A and 20 A | 20 A and 40 A | 10 A | Article No. | 6EP4131-0GB00-0AY0 | 6EP4133-0GB00-0AY0 | 6EP4134-0GB00-0AY0 | 6EP4135-0GB00-0AY0 | 6EP4132-0GB00-0AY0 | Recommended end of charge voltage (set automatically by SITOP UPS1600): | 26.4…27.3 V DC (> +20 °C), 27.3…29.0 V DC (< +20 °C) | 26.4…27.3 V DC (> +20 °C), 27.3…29.0 V DC (< +20 °C) | 26.4…27.3 V DC (> +20 °C), 27.3…29.0 V DC (< +20 °C) | 26.4 … 27.3 V DC (> +20 °C), 27.3 … 29.0 V DC (< +20 °C) | 29 V (-10 °C); 28.6 V (0 °C), 28.3 V (+10 °C); 27.9 V (+20 °C); 27.2 V (+40 °C); 26.8 V (+50 °C) 26.4 V (+60 °C) | Charging current | max. 0.3 A | max. 0.8 A | max. 1.75 A | max. 3 A | max. 5 A | Rated output voltage | 24 V DC, 22...27.0 V DC (no load) | 24 V DC, 22...27.0 V DC (no load) | 24 V DC, 22...27.0 V DC (no load) | 24 V DC, 22...27.0 V DC (no load) | 24 V DC, 22...27.0 V DC (no load) | Rated output current | 10 A | 20 A | 40 A | 40 A | 20 A | Integral battery fuse | 15 A | 25 A | 2 x 25 A | 2 x 25 A | 25 A | Signaling | LED green: Battery OK, flashing green: Error or warning, OFF: No communication | LED green: Battery OK, flashing green: Error or warning, OFF: No communication | LED green: Battery OK, flashing green: Error or warning, OFF: No communication | LED green: Battery OK, flashing green: Error or warning, OFF: No communication | LED green: Battery OK, flashing green: Error or warning, OFF: No communication | Degree of protection (EN 60529) | IP00 | IP00 | IP00 | IP00 | IP00 | Ambient temperature | 0…+40 °C | 0…+40 °C | 0…+40 °C | 0…+40 °C | -40 … +60°C | Transport/storage temperature | -20 …+50°C | -20 …+50°C | -20 …+50°C | -20 …+50°C | -40 … +60°C | Service life (when capacity falls to 50 % of original capacity), depending on battery temperature, approx. | +20 °C: 4 years, +30 °C: 2 years, +40 °C: 1 year, +50 °C: 0.5 years | +20 °C: 4 years, +30 °C: 2 years, +40 °C: 1 year, +50 °C: 0.5 years | +20 °C: 4 years, +30 °C: 2 years, +40 °C: 1 year, +50 °C: 0.5 years | +20 °C: 4 years, +30 °C: 2 years, +40 °C: 1 year, +50 °C: 0.5 years | +20 °C: 10 years, +30 °C: 7 years, +40 °C: 3 years, +50 °C: 1.5 years, +60 °C: 1 year | Installation | DIN rail or wall mounting | DIN rail or wall mounting | Wall mounting | Wall mounting | DIN rail or wall mounting | Dimensions (W x H x D) in mm | 89 x 130 x 107 | 190 x 169 x 79.5 | 186 x 186 x 110.5 | 253 x 168 x 110.5 | 265 x 115 x 63 | Weight, approx. | 1.9 kg | 3.8 kg | 6.1 kg | 9.3 kg | 3.7 kg | Certifications | CE, C-Tick, KCC, cULus, cCSAus, CB, ATEX, IECEx, cCSAus Class I Div2, GL, available soon: ABS | CE, C-Tick, KCC, cULus, cCSAus, CB, ATEX, IECEx, cCSAus Class I Div2, GL, available soon: ABS | CE, C-Tick, KCC, cULus, cCSAus, CB, ATEX, IECEx, cCSAus Class I Div2, GL, available soon: ABS | CE, C-Tick, KCC, cULus, cCSAus, CB, ATEX, IECEx, GL, available soon: cCSAus Class I Div 2, ABS | CE, C-Tick, KCC, cULus, cCSAus, CB, ATEX, IECEx, GL, available soon: cCSAus Class I Div 2, ABS |
|
|