SIMATIC EMS400S IR-DUTechnical specifications | SIMATIC EMS400S IR-DU | Power supply | | Rated voltage | 24 V DC | Power consumption, typical | Approx. 0.1 A | Infrared reception | | Opening angle | < 120° | Range | Min. 10 m | Interface for external infrared sensor | | Quantity | 1 | Data exchange interface | | Quantity | 1 | Type | RS 232-based | Ambient conditions | | Degree of protection | | Front | IP65 | Rear | IP20 | Ambient temperature | | During operation | 0 °C to +60 °C | Relative humidity | 10% to 95%, no condensation | Storage temperature | -20 °C to +60 °C | Certifications | CE, cUL | Dimensions | | Dimensions (W x H x D) in mm | 140 x 116 x 37.5 | Weight | < 350 g |
|
|