The Single Motor Modules in booksize compact format feature the following connections and interfaces as standard:
2 DC link connections via integrated DC link busbars
1 electronics power supply connection via integrated 24 V DC busbars
3 DRIVE?CLiQ sockets
1 motor connection via connector
1 safe standstill input (enable pulses)
1 safe motor brake control
1 temperature sensor input (KTY84?130 or PTC)
2 PE (protective earth) connections
The status of the Motor Modules is indicated via two multi-color LEDs.
The shield of the motor cable is routed over the connector to the motor connection.
The signal cable shield can be connected to the Motor Module by means of a shield connection terminal, e.g. Weidmuller type KLBU 3-8 SC.
The scope of supply of the Motor Modules includes:
DRIVE?CLiQ cable (length depends on module width) to connect Motor Module to adjacent Motor Module length 0.11 m (4.33 in) for 50 mm (1.97 in) wide Motor Modules or length 0.16 m (6.3 in) for 75 mm (2.95 in) wide Motor Modules.
2 blanking plugs for sealing unused DRIVE?CLiQ sockets
Jumper for connecting the 24 V DC busbar to the adjacent Motor Module