SIDOOR ATD400S platform screen door driveDuring initial commissioning, please note the following: - For mechanical installation and configuration, see the "SIDOOR Door Control Systems AT40, ATD400K, ATD400S, ATD400V, ATD400W" manual.http://support.automation.siemens.com/WW/view/de/58531074
- Electrical configuration and commissioning:
- Push the door into the "CLOSED" position.
- Open the device cover
- Plug in the motor connector
- Connect NT40 switch mode power supply to 230 V AC mains supply
- Press and hold the learn run button
- Connect the NT40 switch mode power supply output to the input of the SIDOOR ATD400S Platform Screen Door Drive
- The learn run starts automatically and the learn run button can be released.
- On completion of the learn run, the door is in the "CLOSED" position and the 7-segment display indicates "u".
- The door can now be moved via the "OPEN" and "CLOSE" buttons with the default profile.
|
|