Product designation | | HCS716I power module LA716 | HCS716I power module LA716I | HCS716I power module LA716I HP |
General technical data: | | | | |
Control version / of heat emitters | | Full-wave control |
Type of load | | Ohmic load |
Equipment marking / acc. to DIN EN 81346-2 | | Q |
Degree of pollution | | 2 |
Supply voltage: | | | | |
Switching capacity current / per phase / maximum | A | 23 | 32 |
Design of the electrical isolation | | Optocoupler between main circuit and SELV/PELV |
Power capacity | | | | |
| | | | |
| kW | 10.4 | 14.72 |
| kW | 6.2 | 6.5 |
| kW | 10.4 | 14.72 |
Type of electrical connection / for supply voltage | | Terminal, 3-pin | Connector, 3-pin |
Type of connectable conductor cross-section | | | | |
| | | | |
| | 1x (0.5 ... 6 mm?) | 1x (0.2 ... 10 mm?) |
| | 1x (0.5 ... 4 mm?) | 1x (0.25 ... 6 mm?) |
| | 22 ... 10 | 24 ... 8 |
Power Electronics: | | | | |
Number of outputs / for heating power | | 16 | 8 |
Number of heat emitters / per output / maximum | | 1 |
Output voltage / with star connection | V | 230 |
Design of the overvoltage protection | | Transil diodes |
Power capacity / per output | | | | |
| W | 75 |
| W | 650 | 1 150 | 2 300 |
Output current / at output / for heating power / Rated value | A | 5 | 10 |
Design of short-circuit protection / for heating power / per output | | Fuse 5 A | Fuse 10 A |
| | No |
Type of electrical connection / at output / for heating and fan | | Socket strip, 8-pole |
Type of connectable conductor cross-section | | | | |
| | | | |
| | 1x (0.2 ... 1.5 mm?) |
| | 1x (0.2 ... 1.5 mm?) |
| | 28 ... 16 |
Installation/ mounting/ dimensions: | | | | |
Depth | mm | 241 | 279 |
Width | mm | 31 |
Height | mm | 233.4 |
Further information: | | | | |
Design of the power supply | | Power supply via module rack |
Type of the temperature monitoring | | NTC thermistor |
Diagnostics function | | | | |
| | Yes |
| | Yes |
| | Yes |