Determining the QT... or QM... package number using the following package overview
Selection of the CNC and additional components from this catalog
For easier selection of the CNC and additional components, use of the SIZER for Siemens Drives engineering tool is recommended. Example for ordering a Quick Package QM... |
1. Choose motors for feed, e.g. 11 Nm/16 Nm/16 Nm, with holding brake, in the package overview. | 1FK7063-2AF71-1RH1 |
2. Choose motor for spindle, e.g. 7 kW, type of construction IM B3, in the package overview. | 1PH8105-1DF00-0LA1 |
3. Find SINAMICS S120 Combi drive system with the help of the color code of the package number in the package overview: | 6SL3111-4VE21-6EA0 |
4. Use SIZER to determine the complete configuration including the motor selection from step 1 and step 2. During the configuration, verify whether the drive system corresponds to step 3. | |
5. Find package number in the package overview, e.g. for SINUMERIK 828D BASIC PPU 240.3, and specify this together with the parts list in the order. | QMB3140407 |
Motor versions for Quick Packages
SIMOTICS S-1FK7 feed motors
- Compact or High Inertia
- Absolute encoder 20 bit + 12 bit multi-turn (AM20DQI encoder)
- DE shaft extension: Plain shaft
- Shaft and flange accuracy: Tolerance N
- Holding brake: With or without
- Degree of protection IP65
- Paint finish: Anthracite RAL 7016
SIMOTICS M-1PH8 spindle motors for turning machines
- 22 bit incremental encoder + commutation position 11 bit (IC22DQ encoder)
- Cooling: Forced ventilation from DE to NDE
- Type of construction: IM B3 or IM B5
- DE shaft extension: Plain shaft
- Bearing version: Standard
- Vibration severity: Grade S/A
- Shaft and flange accuracy: Tolerance R
- Cable connection: Terminal box top/cable entry from right/signal connection DE
SIMOTICS M-1PH8 spindle motors for milling machines
- SIMOTICS M-1PH808: 20 bit incremental encoder without commutation position (IN20DQ encoder)
- SIMOTICS M-1PH810/1PH813: 22 bit incremental encoder + commutation position 11 bit (IC22DQ encoder)
- Cooling: Forced ventilation from DE to NDE
- Type of construction: IM B3 or IM B5
- DE shaft extension: Plain shaft
- Bearing version: Performance
- Vibration severity: Grade SPECIAL/B
- Shaft and flange accuracy: Tolerance SPECIAL
- Cable connection: Terminal box top/cable entry from right/signal connection DE