Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2016
архивный
(4872) 700-366
skenergo@mail.ru

SIPLUS smart

Order number

6EP1332-2BA20

6EP1333-2BA20

6EP1334-2BA20

6EP1336-2BA10

Product

SITOP PSU100S

SITOP PSU100S

SITOP PSU100S

SITOP PSU100S

Power supply, type

24 V/2.5 A

24 V/5 A

24 V/10 A

24 V/20 A

Input

 

 

 

 

Input

1-phase AC

1-phase AC

1-phase AC

1-phase AC

Supply voltage

 

 

 

 

  • ? 1 with AC Rated value

120 V

120 V

120 V

120 V

  • ? 2 with AC Rated value

230 V

230 V

230 V

230 V

  • ? Note

Automatic range selection

Automatic range selection

Automatic range selection

Automatic range selection

Input voltage

 

 

 

 

  • ? 1 with AC

85 ... 132 V

85 ... 132 V

85 ... 132 V

85 ... 132 V

  • ? 2 with AC

170 ... 264 V

170 ... 264 V

170 ... 264 V

176 ... 264 V

Wide-range input

No

No

No

No

Overvoltage resistance

2.3 ? Vin rated, 1.3 ms

2.3 ? Vin rated, 1.3 ms

2.3 ? Vin rated, 1.3 ms

2.3 ? Vin rated, 1.3 ms

Mains buffering at Iout rated, min.

20 ms; at Vin = 93/187 V

20 ms; at Vin = 93/187 V

20 ms; at Vin = 93/187 V

20 ms; at Vin = 120/230 V

Rated line frequency

50 ... 60 Hz

50 ... 60 Hz

50 ... 60 Hz

50 ... 60 Hz

Rated line range

47 ... 63 Hz

47 ... 63 Hz

47 ... 63 Hz

47 ... 63 Hz

Input current

 

 

 

 

  • ? at rated input voltage 120 V

1.25 A

2.34 A

4.49 A

7.5 A

  • ? at rated input voltage 230 V

0.74 A

1.36 A

1.91 A

3.5 A

Switch-on current limiting (+25 °C), max.

33 A

40 A

60 A

11 A

I?t, max.

0.4 A?·s

1 A?·s

5.6 A?·s

10 A?·s

Built-in incoming fuse

T 3,15 A/250 V (not accessible)

T 3,15 A/250 V (not accessible)

T 6.3 A/250 V (not accessible)

T 10 A (not accessible)

Protection in the mains power input (IEC 898)

Recommended miniature circuit breaker: from 3 A characteristic C

Recommended miniature circuit breaker: from 6 A characteristic C

Recommended miniature circuit breaker: from 10 A characteristic C

Recommended miniature circuit breaker: from 10 A characteristic C or circuit-breaker 3RV2411-1JA10 (120 V) or 3RV2411-1FA10 (230 V)

Output

 

 

 

 

Output

Controlled, isolated DC voltage

Controlled, isolated DC voltage

Controlled, isolated DC voltage

Controlled, isolated DC voltage

Rated voltage Vout DC

24 V

24 V

24 V

24 V

Total tolerance, static ±

3 %

3 %

3 %

3 %

Static mains compensation, approx.

0.1 %

0.1 %

0.1 %

0.5 %

Static load balancing, approx.

1 %

1 %

1 %

1 %

Residual ripple peak-peak, max.

150 mV

150 mV

150 mV

150 mV

Residual ripple peak-peak, typ.

30 mV

30 mV

20 mV

Spikes peak-peak, max. (bandwidth: 20 MHz)

240 mV

240 mV

240 mV

240 mV

Spikes peak-peak, typ. (bandwidth: 20 MHz)

70 mV

140 mV

160 mV

Adjustment range

22.8 ... 28 V

22.8 ... 28 V

22.8 ... 28 V

24 ... 28 V

Product function Output voltage adjustable

Yes

Yes

Yes

Yes

Output voltage setting

via potentiometer

via potentiometer

via potentiometer

via potentiometer; max. 480 W

Status display

Green LED for 24 V OK

Green LED for 24 V OK

Green LED for 24 V OK

Green LED for 24 V OK

Signaling

Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK"

Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK"

Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK"

Relay contact (NO contact, rating 50 V DC/ 0.3 A) for "24 V OK"

On/off behavior

Overshoot of Vout < 3 %

Overshoot of Vout < 3 %

Overshoot of Vout < 3 %

No overshoot of Vout (soft start)

Startup delay, max.

0.3 s

0.3 s

0.3 s

1.5 s

Voltage rise, typ.

15 ms

15 ms

20 ms

50 ms

Voltage increase time of the output voltage maximum

500 ms

Rated current value Iout rated

2.5 A

5 A

10 A

20 A

Current range

0 ... 3 A

0 ... 6 A

0 ... 12 A

0 ... 20 A

  • ? Note

3 A up to +45°C; +60 ... +70 °C: Derating 3%/K

6 A up to +45°C; +60 ... +70 °C: Derating 1.6%/K

12 A up to +45°C; +60 ... +70 °C: Derating 3%/K

24 A up to +45°C; +60 ... +70 °C: Derating 5%/K

Active power supplied typical

60 W

144 W

288 W

480 W

Short-term overload current

 

 

 

 

  • ? on short-circuiting during the start-up typical

9 A

18 A

32 A

35 A

  • ? at short-circuit during operation typical

9 A

18 A

32 A

35 A

Duration of overloading capability for excess current

 

 

 

 

  • ? on short-circuiting during the start-up

100 ms

800 ms

1 000 ms

100 ms

  • ? at short-circuit during operation

800 ms

800 ms

1 000 ms

100 ms

Parallel switching for enhanced performance

Yes

Yes

Yes

Yes

Numbers of parallel switchable units for enhanced performance

2

2

2

2

Efficiency

 

 

 

 

Efficiency at Vout rated, Iout rated, approx.

85 %

88 %

90 %

90 %

Power loss at Vout rated, Iout rated, approx.

10 W

16 W

25 W

53 W

Closed-loop control

 

 

 

 

Dynamic mains compensation (Vin rated ±15 %), max.

0.3 %

0.3 %

0.3 %

1 %

Dynamic load smoothing (Iout: 50/100/50 %), Uout ± typ.

3 %

Dynamic load smoothing (Iout: 10/90/10 %), Uout ± typ.

5 %

3 %

3 %

Load step setting time 10 to 90%, typ.

1 ms

1 ms

1 ms

Load step setting time 90 to 10%, typ.

1 ms

1 ms

1 ms

Setting time maximum

10 ms

Protection and monitoring

 

 

 

 

Output overvoltage protection

protection against overvoltage in case of internal fault Vout < 33 V

protection against overvoltage in case of internal fault Vout < 33 V

protection against overvoltage in case of internal fault Vout < 33 V

Yes, according to EN 60950-1

Current limitation

3 ... 3.4 A

6 ... 7.1 A

12 ... 14.6 A

Current limitation, typ.

21 A

Property of the output Short-circuit proof

Yes

Yes

Yes

Yes

Short-circuit protection

Constant current characteristic

Constant current characteristic

Constant current characteristic

Electronic shutdown, automatic restart

Enduring short circuit current RMS value

 

 

 

 

  • ? maximum

7 A

  • ? typical

3.4 A

7.1 A

14.6 A

Overcurrent overload capability in normal operation

overload capability 150 % Iout rated up to 5 s/min

overload capability 150 % Iout rated up to 5 s/min

overload capability 150 % Iout rated up to 5 s/min

overload capability 150 % Iout rated up to 5 s/min

Overload/short-circuit indicator

-

-

-

-

Safety

 

 

 

 

Primary/secondary isolation

Yes

Yes

Yes

Yes

Galvanic isolation

Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178

Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178

Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178

Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178

Protection class

Class I

Class I

Class I

Class I

Leakage current

 

 

 

 

  • ? maximum

3.5 mA

3.5 mA

3.5 mA

3.5 mA

  • ? typical

0.4 mA

0.4 mA

0.8 mA

1 mA

CE mark

Yes

Yes

Yes

Yes

UL/CSA approval

Yes

Yes

Yes

Yes

UL/cUL (CSA) approval

cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259, cCSAus (CSA C22.2 No. 60950-1, UL 60950-1, UL 1604)

cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259, cCSAus (CSA C22.2 No. 60950-1, UL 60950-1, UL 1604)

cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259, cCSAus (CSA C22.2 No. 60950-1, UL 60950-1, UL 1604)

cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; in preparation: cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)

Explosion protection

ATEX (EX) II 3G Ex nA nC IIC T4 Gc; cCSAus (CSA C22.2 No. 213-M1987, ANSI/ISA-12.12.01-2007) Class I, Div. 2, Group ABCD, T4

ATEX (EX) II 3G Ex nA nC IIC T4 Gc; cCSAus (CSA C22.2 No. 213-M1987, ANSI/ISA-12.12.01-2007) Class I, Div. 2, Group ABCD, T4

ATEX (EX) II 3G Ex nA nC IIC T4 Gc; cCSAus (CSA C22.2 No. 213-M1987, ANSI/ISA-12.12.01-2007) Class I, Div. 2, Group ABCD, T4

ATEX (EX) II 3G Ex nA nC IIC T4 Gc; cCSAus (CSA C22.2 No. 213, ANSI/ISA-12.12.01) Class I, Div. 2, Group ABCD, T4

Certificate of suitability IECEx

No

No

No

No

Certificate of suitability NEC Class 2

No

No

No

No

FM approval

-

-

-

-

CB approval

Yes

Yes

Yes

Yes

Marine approval

GL, BV

GL, BV

GL, BV

GL

Degree of protection (EN 60529)

IP20

IP20

IP20

IP20

EMC

 

 

 

 

Emitted interference

EN 55022 Class B

EN 55022 Class B

EN 55022 Class B

EN 55022 Class B

Supply harmonics limitation

not applicable

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Noise immunity

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

Operating data

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-25 ... +70 °C

-25 ... +70 °C

-25 ... +70 °C

0 ... 70 °C

  • Note

with natural convection

with natural convection

with natural convection

with natural convection

  • ? during transport

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

  • ? during storage

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

Humidity class according to EN 60721

Climate class 3K3, no condensation

Climate class 3K3, no condensation

Climate class 3K3, no condensation

Climate class 3K3, no condensation

Mechanics

 

 

 

 

Connection technology

screw-type terminals

screw-type terminals

screw-type terminals

screw-type terminals

Connections

 

 

 

 

  • ? Supply input

L, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm? single-core/finely stranded

L, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm? single-core/finely stranded

L, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm? single-core/finely stranded

L1, N, PE: 1 screw terminal each for 0.2 ... 4 mm? single-core/finely stranded

  • ? Output

+, -: 2 screw terminals each for 0.5 ... 2.5 mm?

+, -: 2 screw terminals each for 0.5 ... 2.5 mm?

+, -: 2 screw terminals each for 0.5 ... 2.5 mm?

+, -: 2 screw terminals each for 0.2 ... 4 mm?

  • ? Auxiliary

Alarm signals: 2 screw terminals for 0.5 ... 2.5 mm?

Alarm signals: 2 screw terminals for 0.5 ... 2.5 mm?

Alarm signals: 2 screw terminals for 0.5 ... 2.5 mm?

13, 14 (alarm signal): 1 screw terminal each for 0.14 ... 1.5 mm?

Width of the enclosure

32.5 mm

50 mm

70 mm

115 mm

Height of the enclosure

125 mm

125 mm

125 mm

145 mm

Depth of the enclosure

120 mm

120 mm

120 mm

150 mm

Weight, approx.

0.32 kg

0.5 kg

0.8 kg

2.4 kg

Product property of the enclosure housing for side-by-side mounting

Yes

Yes

Yes

Yes

Installation

Snaps onto DIN rail EN 60715 35x7.5/15

Snaps onto DIN rail EN 60715 35x7.5/15

Snaps onto DIN rail EN 60715 35x7.5/15

Snaps onto DIN rail EN 60715 35x7.5/15

Electrical accessories

Buffer module

Buffer module

Buffer module

Buffer module

Mechanical accessories

Device identification label 20 mm ? 7 mm, pastel-turpuoise 3RT1900-1SB20

Other information

Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)

Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)

Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)

Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2016
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Блоки питания SITOP Блоки питания серии SITOP lite SITOP compact Блоки питания серии SITOP compact Блоки питания серии LOGO!Power SITOP lite Блоки питания серии SITOP smart Модульные блоки питания SITOP SITOP modular, PSU8600 power supply system SITOP в исполнении SIMATIC Специальное исполнение и назначение Дополнительные компоненты Блоки бесперебойного питания DC-UPS Аксессуары Блоки питания заказного исполнения Семейство SIPLUS Introduction SIPLUS LOGO!Power SIPLUS smart SIPLUS smart SIPLUS PS PSU300S SIPLUS modular SIPLUS исполнение S7 SIPLUS DC/DC converter SIPLUS модулли add-on SIPLUS DC-UPS, бесперебойные источники питания Блоки питания для AS-интерфейса Техническая информация и проектирование SITOP power для AS-Interface Трансформаторы, источники питания и системы SIDAC Photovoltaics Продукты для специальных требований Автоматизация и безопасность зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо




  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика