Input | |
Measured variable | Gauge pressure (flush-mounted) |
| HART | PROFIBUS PA/ FOUNDATION Fieldbus | | |
Span (fully adjustable) or nominal measuring range and max. permissible test pressure | Span | Nominal measuring range | Max. perm. operating pressure MAWP (PS) | Max. permissible test pressure |
0.01 ... 1 bar 1 ... 100 kPa 0.15 ... 14.5 psi | 1 bar 100 kPa 14.5 psi | 4 bar 400 kPa 58 psi | 6 bar 600 kPa 87 psi |
0.04 ... 4 bar 4 ... 400 kPa 0.58 ... 58 psi | 4 bar 400 kPa 58 psi | 7 bar 0.71 MPa 102 psi | 10 bar 1 MPa 145 psi |
0.16 ... 16 bar 16 ... 1600 kPa 2.3 ... 232 psi | 16 bar 1600 kPa 232 psi | 21 bar 2.1 MPa 305 psi | 32 bar 3.2 MPa 464 psi |
Lower measuring limit (for PMC Style Minibolt no span < 500 mbar adjustable) | 100 mbar a/10 kPa a/1.45 psia |
Upper measuring limit | 100 % of max. span |
Output | HART | PROFIBUS PA/ FOUNDATION Fieldbus |
Output signal | 4 ... 20 mA | Digital PROFIBUS PA signal |
- Lower limit (fully adjustable)
| 3.55 mA, factory preset to 3.84 mA | - |
- Upper limit (fully adjustable)
| 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA | - |
Load | | |
| RB ? (UH - 10.5 V)/0.023 A in ?, UH: Power supply in V | - |
| RB = 230 ... 500 ? (SIMATIC PDM) or RB = 230 ... 1100 ? (HART Communicator) | - |
Physical bus | - | IEC 61158-2 |
Protection against polarity reversal | Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. |
Electrical damping (step width 0.1 s) | Set to 2 s (0 ... 100 s) |
Measuring accuracy | According to IEC 60770-1 |
Reference conditions | - Rising characteristic curve
- Start of scale 0 bar
- Seal diaphragm stainless steel
- Silicone oil filling
- Room temperature (25 °C (77 °F))
|
Measuring span ratio r (spread, Turn-Down) | r = maximum measuring span/set measuring span or nominal measuring range |
Error in measurement at limit setting including hysteresis and reproducibility | |
| |
| ? 0.075 % |
| ? (0.005 · r + 0.05) % |
Influence of ambient temperature | ? (0.08 · r + 0.16) % |
Long-term stability (temperature change ±30 °C (±54 °F)) | ? (0.25 · r) % in 5 years |
Influence of mounting position | ? 0.1 mbar/0.01 kPa/0.00145 psi per 10° incline (zero point correction is possible with position error compensation) |
Effect of auxiliary power (in percent per voltage change) | 0.005 % per 1 V |
Measured-value resolution for PROFIBUS PA and FOUNDATION Fieldbus | 3 · 10-5 of nominal measuring range |
Rated conditions | |
Installation conditions | |
Ambient temperature | Observe the temperature class in areas subject to explosion hazard. |
- Measuring cell with silicone oil
| -40 ... +85 °C (-40 ... +185 °F) |
| -30 ... +85 °C (-22 ... +185 °F) |
| -50 ... +85 °C (-58 ... +185 °F) |
Climatic class | |
Condensation | Relative humidity 0 ... 100 % Condensation permissible, suitable for use in the tropics |
Degree of protection acc. to EN 60529 | IP65, IP68, NEMA 4X, enclosure cleaning, resistant to lyes, steam to 150 °C (302 °F) |
Electromagnetic Compatibility | |
- Emitted interference and interference immunity
| Acc. to EN 61326 and NAMUR NE 21 |
Process conditions | |
Temperature of medium | |
- Measuring cell with silicone oil
| -40 ... +100 °C (-40 ... +212 °F) |
Design | |
Weight (without options) | Approx. 1 kg (2.2 lb) |
Enclosure material | Stainless steel, mat. no. 1.4301/304 |
Material of parts in contact with the medium | |
| Hastelloy C276, mat. no. 2.4819 |
| Silicone oil |
Surface quality touched-by-media | Ra-values ? 0.8 µm (32 µ-inch)/welds Ra ? 1.6 µm (64 µ-inch) |
Power supply UH | HART | PROFIBUS PA/ FOUNDATION Fieldbus |
Terminal voltage on transmitter | 10.5 ... 42 V DC for intrinsically safe operation: 10.5 ... 30 V DC | - |
Auxiliary power | - | Bus-powered |
Separate power supply | - | Not necessary |
Bus voltage | | |
| - | 9 ... 32 V |
- With intrinsically-safe operation
| - | 9 ... 24 V |
Current consumption | | |
| - | 12.5 mA |
- Start-up current ? basic current
| - | Yes |
- Max. fault current in the event of a fault
| - | 15.5 mA |
Fault disconnection electronics (FDE) available | - | Yes |
Certificates and approvals | HART | PROFIBUS PA/ FOUNDATION Fieldbus |
Classification according to PED 97/23/EC | For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) |
Explosion protection | |
Intrinsic safety "i" | PTB 05 ATEX 2048 |
Marking | Ex II 1/2 G EEx ia/ib IIB/IIC T4, T5, T6 |
Permissible ambient temperature | |
| -40 ... +85 °C (-40 ... +185 °F) |
| -40 ... +70 °C (-40 ... +158 °F) |
| -40 ... +60 °C (-40 ... +140 °F) |
Connection | To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 ? | To certified intrinsically-safe circuits with peak values: FISCO supply unit: Ui = 17.5 V, Ii = 380 mA, Pi = 5.32 W Linear barrier: Ui = 24 V, Ii = 250 mA, Pi = 1.2 W |
Effective internal capacitance | Ci = 6 nF | Ci = 1.1 nF |
Effective internal inductance | Li = 0.4 mH | Li ? 7 ?H |
Explosion protection to FM for USA and Canada (cFMUS) | |
- Identification (DIP) or (IS); (NI)
| Certificate of Compliance 3025099 CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4 ... T6; CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III |
- Identification (DIP) or (IS)
| Certificate of Compliance 3025099C CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4 ... T6; CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III |