Transmission rate | |
Transfer rate | |
| 10 ... 1 000 Mbit/s |
| 10 ... 100 Mbit/s |
Interfaces | |
Number of interfaces acc. to Industrial Ethernet | 5 |
Number of electrical connections | |
| 1 |
| 4 |
Type of electrical connection | |
| RJ45 port |
| RJ45 port |
design of the removable storage C-PLUG | Yes |
Supply voltage, current consumption, power loss | |
Type of voltage of the supply voltage | DC |
Supply voltage 1 from backplane bus | 5 V |
Relative symmetrical tolerance for DC | |
| 5 % |
Consumed current | |
| 1.8 A |
Active power loss | 9 W |
Permitted ambient conditions | |
Ambient temperature | |
| 0 ... 60 °C |
| -40 ... +70 °C |
| -40 ... +70 °C |
Relative humidity at 25 °C without condensation during operation maximum | 95 % |
Protection class IP | IP20 |
Design, dimensions and weight | |
Module format | Compact module S7-400 single width |
Width | 25 mm |
Height | 290 mm |
Depth | 210 mm |
Net weight | 0.7 kg |
Product properties, functions, components general | |
Number of units | |
| 14 |
| max. 4 as PN IO ctrl. |
Performance data open communication | |
Number of possible connections for open communication by means of SEND/RECEIVE blocks | |
| 64 |
Amount of data | |
| 8 Kibyte |
| 8 Kibyte |
| 8 Kibyte |
| 2 Kibyte |
Number of possible connections for open communication | |
| 64 |
Amount of data | |
| 1 452 byte |
Performance data S7 communication | |
Number of possible connections for S7 communication | |
| 128 |
| 2 |
| when using several CPUs |
Performance data multi-protocol mode | |
Number of active connections with multi-protocol mode | 128 |
Performance data IT functions | |
Number of possible connections | |
| 20 |
| 10 |
| 4 |
| 1 |
Amount of data as user data for email maximum | 8 Kibyte |
Storage capacity of the user memory | |
| 30 Mibyte |
| 16 Mibyte |
| 512 Kibyte |
Number of possible write cycles of the flash memory cells | 100 000 |
Performance data PROFINET communication as PN IO-Controller | |
Product function PROFINET IO controller | Yes |
Number of PN IO devices on PROFINET IO controller usable total | 128 |
Number of PN IO IRT devices on PROFINET IO controller usable | 64 |
Number of external PN IO lines with PROFINET per rack | 4 |
Amount of data | |
| 8 Kibyte |
| 8 Kibyte |
| 1 433 byte |
| 1 433 byte |
| 240 byte |
| 240 byte |
Performance data PROFINET CBA | |
Number of remote connection partners with PROFINET CBA | 64 |
Number of connections with PROFINET CBA total | 600 |
Amount of data | |
| 8 Kibyte |
| 8 Kibyte |
| 8 Kibyte |
| 250 byte |
| 2 400 byte |
Performance data PROFINET CBA remote connection with acyclic transmission | |
Refresh time of the remote interconnections in the case of acyclic transmission with PROFINET CBA | 100 ms |
Number of remote connections to input variables in the case of acyclic transmission with PROFINET CBA maximum | 150 |
Number of remote connections to output variables in the case of acyclic transmission with PROFINET CBA maximum | 150 |
Amount of data | |
| 8 Kibyte |
| 8 Kibyte |
Performance data PROFINET CBA remote connection with cyclic transmission | |
Refresh time of the remote interconnections with PROFINET CBA with cyclical transfer | 10 ms |
Number of remote connections to input variables with PROFINET CBA with cyclical transfer maximum | 250 |
Number of remote connections to output variables with PROFINET CBA with cyclical transfer maximum | 250 |
Amount of data | |
| 2 000 byte |
| 2 000 byte |
Performance data PROFINET CBA HMI variables via PROFINET acyclic | |
Number of connectable HMI stations for HMI variables in the case of acyclic transmission with PROFINET CBA | 3 |
Refresh time of the HMI variables in the case of acyclic transmission with PROFINET CBA | 500 ms |
Number of HMI variables in the case of acyclic transmission with PROFINET CBA maximum | 200 |
Amount of data as user data for HMI variables in the case of acyclic transmission with PROFINET CBA maximum | 8 Kibyte |
Performance data PROFINET CBA device-internal connections | |
Number of internal connections with PROFINET CBA maximum | 300 |
Amount of data of the internal connections with PROFINET CBA maximum | 2 400 byte |
Performance data PROFINET CBA connections to constants | |
Number of connections with constants with PROFINET CBA maximum | 500 |
Amount of data as user data for interconnections with constants with PROFINET CBA maximum | 4 000 byte |
Performance data PROFINET CBA PROFIBUS proxy functionality | |
Product function with PROFINET CBA PROFIBUS proxy functionality | No |
Performance data telecontrol | |
Protocol is supported | |
| Yes |
Product functions management, configuration | |
Product function MIB support | Yes |
Protocol is supported | |
| Yes |
| Yes |
| Yes |
| Yes |
Configuration software | |
| STEP 7 V5.5 SP3 or higher / STEP 7 Professional V12 (TIA Portal) or higher |
| SIMATIC iMap V3.0 SP1 and higher |
Product functions Diagnosis | |
Product function Web-based diagnostics | Yes |
Product functions switch | |
Product feature Switch | Yes |
Product function | |
| No |
| Yes |
| Yes |
Product functions Redundancy | |
Product function | |
| Yes |
| Yes |
Protocol is supported Media Redundancy Protocol (MRP) | Yes |
Product functions Security | |
Firewall version | stateful inspection |
Product function with VPN connection | IPSec |
Type of encryption algorithms with VPN connection | AES-256, AES-192, AES-128, 3DES-168, DES-56 |
Type of authentication procedure with VPN connection | Preshared key (PSK), X.509v3 certificates |
Type of hashing algorithms with VPN connection | MD5, SHA-1 |
Number of possible connections with VPN connection | 32 |
Product function | |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| No |
Product functions Time | |
Product function SICLOCK support | Yes |
Product function pass on time synchronization | Yes |
Protocol is supported NTP | Yes |