Transmission rate | |
Transfer rate | |
| 9.6 kbit/s ... 12 Mbit/s |
Interfaces | |
Number of electrical connections | |
| 1 |
Type of electrical connection | |
| 9-pin Sub-D socket (RS 485) |
Supply voltage, current consumption, power loss | |
Type of voltage of the supply voltage | DC |
Supply voltage | |
| 5 V |
Relative symmetrical tolerance for DC | |
| 5 % |
Consumed current | |
| 0.66 A |
Active power loss | 3.3 W |
Permitted ambient conditions | |
Ambient temperature | |
| 0 ... 70 °C |
| -40 ... +70 °C |
| -40 ... +70 °C |
Relative humidity at 25 °C without condensation during operation maximum | 85 % |
Protection class IP | IP00 |
Design, dimensions and weight | |
Module format | PCI-104 |
Width | 90 mm |
Height | 21 mm |
Depth | 96 mm |
Net weight | 80 g |
Mounting type | Screw mounting |
Number of plug-in cards of same design plug-in per PC station | 3 |
Number of units Note | FMS-5613 supports up to two CP 5603 / CP 5613 A2 / CP 5614 A2 / CP 5623 / CP 5624 processors |
Performance data | |
Performance data open communication | |
Software for open communication by means of SEND/RECEIVE required | FDL driver included in scope of delivery of the CP |
Number of possible connections for open communication by means of SEND/RECEIVE maximum | 80 |
Performance data PROFIBUS DP | |
Software for DP master function required | No |
Service as DP master | |
| Yes |
| Yes |
| Yes |
Number of DP slaves on DP master usable | 124 |
Amount of data | |
| 30 256 byte |
| 30 256 byte |
| 244 byte |
| 244 byte |
| 244 byte |
Software for DP slave function required | No |
Service as DP slave | |
| Yes |
| Yes |
Amount of data | |
| 244 byte |
| 244 byte |
Performance data FMS functions | |
Software for FMS communication required | Yes, FMS-5613 |
Number of possible connections for FMS connection maximum | 40 |
Performance data S7 communication | |
Software for S7 communication required | Yes, HARDNET-PB S7 (S7-5613) |
Number of possible connections for S7/PG communication maximum | 50 |
Performance data multi-protocol mode | |
Number of active connections with multi-protocol mode | 50 |
Number of configurable connections per PC station | 207 |
Product functions management, configuration | |
Configuration software required | Included in scope of supply |
Product functions Diagnosis | |
Product function | |
| Yes |
Standards, specifications, approvals | |
Standard | |
| 2004/108/EC |
| CAN/CSA C22.2 & UL 60950-1, UL 508 |
| EN 61000-6-3, EN 61000-6-4 |
| EN 61000-6-1, EN 61000-6-2 |
Certificate of suitability | |
| Yes |
| Yes |
Accessories | |
accessories | optional: Expansion rack for SIMATIC Microbox and slide-in plate for SIMATIC S7 modular embedded controller |