Неуправляемые коммутаторы SIPLUS SCALANCE X-100Order number | 6GK5104-2BB00-2AA3 | 6GK5106-1BB00-2AA3 | 6GK5108-0BA00-2AA3 | 6GK5108-0PA00-2AA3 |
|---|
Product type designation | SCALANCE X104-2 | SCALANCE X106-1 | SCALANCE X108 | SCALANCE X108PoE |
|---|
Transmission rate | | | | | Transfer rate | 10 Mbit/s, 100 Mbit/s | 10 Mbit/s, 100 Mbit/s | 10 Mbit/s, 100 Mbit/s | 10 Mbit/s, 100 Mbit/s | Interfaces | | | | | Number of electrical/optical connections | | | | | | 6 | 7 | 8 | 8 | Number of electrical connections | | | | | | 4 | 6 | 8 | 6 | | | | | 2 | Type of electrical connection | | | | | | RJ45 port | RJ45 port | RJ45 port | RJ45 port | | | | | RJ45 port | Number of optical interfaces | | | | | | 2 | 1 | | | Design of the optical interface | | | | | | BFOC port (multimode up to 5 km) | BFOC port (multimode up to 5 km) | | | Connectable optical power relative to 1 mW | | | | | | -19 ... -14 | -19 ... -14 | | | | -14 dB | -14 dB | | | Optical sensitivity relating to 1 mW of the receiver input minimum | -32 dB | -32 dB | | | Damping ratio of the FOC transmission link minimum necessary | 0 dB | 0 dB | | | Range at the optical interface depending on the optical fiber used | 0 ... 5 km | 0 ... 5 km | | | Interfaces for communication integrated | | | | | Number of 100 Mbit/s ST(BFOC) ports | | | | | | 2 | 1 | | | Number of 100 Mbit/s SC ports | | | | | | 0 | 0 | 0 | 0 | Number of 1000 Mbit/s LC ports | | | | | | 0 | 0 | 0 | 0 | | 0 | 0 | 0 | 0 | Interfaces others | | | | | Number of electrical connections | | | | | | 1 | 1 | 1 | 1 | | 1 | 1 | 1 | 1 | | 1 | 1 | 1 | 1 | Type of electrical connection | | | | | | 2-pole terminal block | 2-pole terminal block | 2-pole terminal block | 2-pole terminal block | | 4-pole terminal block | 4-pole terminal block | 4-pole terminal block | 4-pole terminal block | Signal-Inputs/outputs | | | | | Operating voltage of the signaling contacts | | | | | | 24 V | 24 V | 24 V | 24 V | Operating current of the signaling contacts | | | | | | 0.1 A | 0.1 A | 0.1 A | 0.1 A | Supply voltage, current consumption, power loss | | | | | Type of voltage of the supply voltage | DC | DC | DC | DC | Supply voltage | | | | | | 24 V | 24 V | 24 V | 24 V | | 18 ... 32 V | 18 ... 32 V | 18 ... 32 V | 18 ... 32 V | Product component fusing at power supply input | Yes | Yes | Yes | Yes | Fuse protection type at input for supply voltage | 0.6 A / 60 V | 0.6 A / 60 V | 0.6 A / 60 V | 4 A / 125 V | Consumed current maximum | 0.16 A | 0.15 A | 0.14 A | 1.7 A | Active power loss | | | | | | 3.8 W | 3.6 W | 3.36 W | 10 W | Permitted ambient conditions | | | | | Ambient temperature | | | | | | -10 ... +60 °C | -10 ... +60 °C | -20 ... +70 °C | -20 ... +60 °C | | -40 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | | -40 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | | | | | At 55° C ambient temperature on both sides 40 mm distance to adjacent devices | Relative humidity | | | | | | 95 % | 95 % | 95 % | 95 % | Ambient condition | | | | | | | | | Conformal coating, no | Coating | | | | Conformal Coating, no | Protection class IP | IP30 | IP30 | IP30 | IP30 | Design, dimensions and weight | | | | | Design | compact | compact | compact | compact | Width | 60 mm | 60 mm | 60 mm | 60 mm | Height | 125 mm | 125 mm | 125 mm | 125 mm | Depth | 124 mm | 124 mm | 124 mm | 124 mm | Net weight | 0.78 kg | 0.78 kg | 0.78 kg | 0.9 kg | Mounting type | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | Product functions management, configuration | | | | | Product function | | | | | | No | No | No | No | | No | No | No | No | Standards, specifications, approvals | | | | | Standard | | | | | | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4A, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | | EN 61000-6-4 (Class A) | EN 61000-6-4 (Class A) | EN 61000-6-4 (Class A) | EN 61000-6-4:2001 | | EN 61000-6-2 | EN 61000-6-2 | EN 61000-6-2 | EN 61000-6-2:2001 | Certificate of suitability | EN 61000-6-2, EN 61000-6-4 | EN 61000-6-2, EN 61000-6-4 | EN 61000-6-2, EN 61000-6-4 | EN 61000-6-2:2001, EN 61000-6-4:2001 | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | | | Yes | No | | | | Yes | No | | | | No | Yes | Marine classification association | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | No | | Yes | Yes | Yes | No | MTBF at 40 °C | 134.87 y | 136.65 y | 139.83 y | 61.64 y |
Order number | 6GK5112-2BB00-2AA3 | 6GK5116-0BA00-2AA3 | 6GK5124-0BA00-2AA3 |
|---|
Product type designation | SCALANCE X112-2 | SCALANCE X116 | SCALANCE X124 |
|---|
Transmission rate | | | | Transfer rate | 10 Mbit/s, 100 Mbit/s | 10 Mbit/s, 100 Mbit/s | 10 Mbit/s, 100 Mbit/s | Interfaces | | | | Number of electrical/optical connections | | | | | 14 | 16 | 24 | Number of electrical connections | | | | | 12 | 16 | 24 | Type of electrical connection | | | | | RJ45 port | RJ45 port | RJ45 port | Number of optical interfaces | | | | | 2 | | | Design of the optical interface | | | | | BFOC port (multimode up to 5 km) | | | Connectable optical power relative to 1 mW | | | | | -19 ... -14 | | | | -14 dB | | | Optical sensitivity relating to 1 mW of the receiver input minimum | -32 dB | | | Damping ratio of the FOC transmission link minimum necessary | 0 dB | | | Range at the optical interface depending on the optical fiber used | 0 ... 5 km | | | Interfaces for communication integrated | | | | Number of 100 Mbit/s ST(BFOC) ports | | | | | 2 | | | Number of 100 Mbit/s SC ports | | | | | 0 | 0 | 0 | Number of 1000 Mbit/s LC ports | | | | | 0 | 0 | 0 | | 0 | 0 | 0 | Interfaces others | | | | Number of electrical connections | | | | | 1 | 1 | 1 | | 1 | 1 | 1 | | 1 | 1 | 1 | Type of electrical connection | | | | | 2-pole terminal block | 2-pole terminal block | 2-pole terminal block | | 4-pole terminal block | 4-pole terminal block | 4-pole terminal block | Signal-Inputs/outputs | | | | Operating voltage of the signaling contacts | | | | | 24 V | 24 V | 24 V | Operating current of the signaling contacts | | | | | 0.1 A | 0.1 A | 0.1 A | Supply voltage, current consumption, power loss | | | | Type of voltage of the supply voltage | DC | DC | DC | Supply voltage | | | | | 24 V | 24 V | 24 V | | 18 ... 32 V | 18 ... 32 V | 18 ... 32 V | Product component fusing at power supply input | No | No | No | Consumed current maximum | 0.45 A | 0.3 A | 0.45 A | Active power loss | | | | | 5.16 W | 4.4 W | 4.8 W | Permitted ambient conditions | | | | Ambient temperature | | | | | -10 ... +70 °C | -20 ... +70 °C | -20 ... +70 °C | | -40 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | | -40 ... +80 °C | -40 ... +80 °C | -40 ... +80 °C | Relative humidity | | | | | 95 % | 95 % | 95 % | Protection class IP | IP30 | IP30 | IP30 | Design, dimensions and weight | | | | Design | compact | compact | compact | Width | 120 mm | 120 mm | 180 mm | Height | 125 mm | 125 mm | 125 mm | Depth | 124 mm | 124 mm | 124 mm | Net weight | 1.1 kg | 1.1 kg | 1.5 kg | Mounting type | | | | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | No | No | No | Product functions management, configuration | | | | Product function | | | | | No | No | No | | No | No | No | Standards, specifications, approvals | | | | Standard | | | | | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | | EN 61000-6-4:2001 | EN 61000-6-4:2001 | EN 61000-6-4:2001 | | EN 61000-6-2:2001 | EN 61000-6-2:2001 | EN 61000-6-2:2001 | Certificate of suitability | EN 61000-6-2:2001, EN 61000-6-4:2001 | EN 61000-6-2:2001, EN 61000-6-4:2001 | EN 61000-6-2:2001, EN 61000-6-4:2001 | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | Marine classification association | | | | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | MTBF at 40 °C | 61.3 y | 61.3 y | 49.3 y |
|
|