Transmission rate | |
Transfer rate | |
| 10 ... 100 Mbit/s |
| 50 ... 38 400 bit/s |
Interfaces | |
Number of interfaces acc. to Industrial Ethernet | 1 |
Number of electrical connections | |
| 1 |
| 1 |
Type of electrical connection | |
| RJ45 port |
| 9 pin Sub-D-connector (RS232) |
| 2-pole plugable terminal block |
design of the removable storage C-PLUG | No |
Supply voltage, current consumption, power loss | |
Type of voltage of the supply voltage | DC |
Supply voltage | 24 V |
Supply voltage | 20.4 ... 28.8 V |
Relative symmetrical tolerance for DC | |
| 5 % |
Relative positive tolerance for DC at 24 V | 5 % |
Relative negative tolerance for DC at 24 V | 5 % |
Consumed current | |
| 0.2 A |
| 0.2 A |
Active power loss | 5.8 W |
Product expansion optional Backup battery | No |
Permitted ambient conditions | |
Ambient temperature | |
| 0 ... 60 °C |
| -40 ... +70 °C |
| -40 ... +70 °C |
Relative humidity at 25 °C without condensation during operation maximum | 95 % |
Protection class IP | IP20 |
Design, dimensions and weight | |
Module format | Compact module S7-300 single width |
Width | 40 mm |
Height | 125 mm |
Depth | 120 mm |
Net weight | 0.25 kg |
Product properties, functions, components general | |
Number of units | |
| 1 |
| Number of TIMs per S7-300: 1 |
Cable length | |
| 6 m |
Performance data S7 communication | |
Number of possible connections for S7 communication | |
| 8 |
| 2 |
| 8 |
Service | |
| Yes |
| Yes |
Performance data multi-protocol mode | |
Number of active connections with multi-protocol mode | 12 |
Performance data telecontrol | |
Suitability for use | |
| No |
| Yes |
| No |
| RS232 and Industrial Ethernet can not be operated in parallel |
Protocol is supported | |
| Yes |
| No |
| Yes |
| Yes |
Product function data buffering if connection is aborted | Yes |
| 16,000 data messages |
Storage capacity | |
| 20 Kibyte |
| 0 Kibyte |
| TD7onCPU: at least 20 KB, actual requirement determined by data volume and functional scope TD7onTIM: 0 bytes in most favorable case |
Product property Buffered message frame memory | No |
Transmission format | |
| Yes |
| Yes |
| Yes |
| Yes |
Operating mode for scanning of data transmission | |
| Polling, polling with time slot procedure |
| Polling, polling with time slot procedure, multi-master polling with time slot procedure |
| spontaneous |
| spontaneous |
Hamming distance | |
| 4 |
| 4 |
Product functions management, configuration | |
Configuration software | |
| SINAUT ST7 ES |
| Yes |
| Yes |
Storage location of TIM configuration data | On the TIM |
Product functions Security | |
Suitability for operation Virtual Private Network | Yes |
Operating mode Virtual Private Network note | VPN operation as MSC client with MSC protocol and password protection only possible in conjunction with GPRS modem with MSC capability |
Type of authentication with Virtual Private Network PSK | Yes |
Product function | |
| Yes |
| Yes |
Protocol | |
| No |
Key length for MSC with Virtual Private Network | 128 bit |
Number of possible connections | |
| 1 |
| 0 |