Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2016
архивный
(4872) 700-366
skenergo@mail.ru

SCALANCE XR-300 managed

Order number

6GK5324-0GG00-1AR2

6GK5324-0GG00-1HR2

6GK5324-0GG00-1CR2

Product type designation

SCALANCE XR324-12M

SCALANCE XR324-12M

SCALANCE XR324-12M TS

Transmission rate

 

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

Interfaces

 

 

 

Number of electrical/optical connections

 

 

 

  • ? for network components or terminal equipment maximum

24

24

24

Type of electrical connection

 

 

 

  • ? for network components or terminal equipment

Dependent on selected media modules

Dependent on selected media modules

Dependent on selected media modules

Design of the optical interface

 

 

 

  • ? for fiber optic cable at 100 Mbit/s

Dependent on selected media modules

Dependent on selected media modules

Dependent on selected media modules

  • ? for fiber optic cable at 1000 Mbit/s

Dependent on selected media modules

Dependent on selected media modules

Dependent on selected media modules

Interfaces for communication integrated

 

 

 

Number of 100 Mbit/s ST(BFOC) ports

 

 

 

  • ? for multimode

24

24

24

Number of 100 Mbit/s SC ports

 

 

 

  • ? for multimode

24

24

24

Number of 1000 Mbit/s LC ports

 

 

 

  • ? for multimode

24

24

24

Interfaces others

 

 

 

Number of electrical connections

 

 

 

  • ? for operator console

1

1

1

  • ? for signaling contact

1

1

1

  • ? for media module

12

12

12

  • ? for power supply

1

1

1

  • ? for redundant voltage supply

1

1

1

Type of electrical connection

 

 

 

  • ? for operator console

RJ11 port

RJ11 port

RJ11 port

  • ? for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • ? for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

design of the removable storage

 

 

 

  • ? C-PLUG

Yes

Yes

Yes

Signal-Inputs/outputs

 

 

 

Operating voltage of the signaling contacts

 

 

 

  • ? for DC Rated value

24 V

24 V

24 V

Operating current of the signaling contacts

 

 

 

  • ? for DC maximum

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

Type of voltage supply redundant power supply unit

No

No

No

Type of voltage of the supply voltage

DC

DC

DC

Supply voltage

 

 

 

  • ? external

24 V

24 V

24 V

  • ? external

19.2 ... 28.8 V

19.2 ... 28.8 V

19.2 ... 28.8 V

Product component fusing at power supply input

Yes

Yes

Yes

Fuse protection type at input for supply voltage

F 5 A / 125 V

F 5 A / 125 V

F 5 A / 125 V

Consumed current maximum

1.8 A

1.8 A

1.8 A

Active power loss

 

 

 

  • ? for DC at 24 V

44 W

44 W

44 W

Permitted ambient conditions

 

 

 

Ambient temperature

 

 

 

  • ? during operation

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during storage

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

  • ? during transport

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

  • ? Note

Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 °C.

Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 °C.

Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 °C.

Relative humidity

 

 

 

  • ? at 25 °C without condensation during operation maximum

95 %

95 %

95 %

Ambient condition

 

 

 

  • ? for operation

Conformal coating, no

Conformal coating, no

Conformal coating, yes

Coating

Conformal Coating, no

Conformal Coating, no

Conformal Coating, yes

Protection class IP

IP20

IP20

IP20

Design, dimensions and weight

 

 

 

Design

19" rack

19" rack

19" rack

Number of modular height units relating to 19-inch cabinet

1

1

1

Width

483 mm

483 mm

483 mm

Height

44 mm

44 mm

44 mm

Depth

305 mm

305 mm

305 mm

Net weight

5.5 kg

5.5 kg

5.5 kg

Mounting type

When used in shipbuilding, the device must be secured in the 19" rack at four points

When used in shipbuilding, the device must be secured in the 19" rack at four points

When used in shipbuilding, the device must be secured in the 19" rack at four points

  • ? 19-inch installation

Yes

Yes

Yes

  • ? 35 mm DIN rail mounting

No

No

No

  • ? wall mounting

No

No

No

  • ? S7-300 rail mounting

No

No

No

  • ? S7-1500 rail mounting

No

No

No

Product properties, functions, components general

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

100

Cascading in cases of star topology

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functions management, configuration

 

 

 

Product function

 

 

 

  • ? CLI

Yes

Yes

Yes

  • ? web-based management

Yes

Yes

Yes

  • ? MIB support

Yes

Yes

Yes

  • ? TRAPs via email

Yes

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

Yes

  • ? RMON

Yes

Yes

Yes

  • ? Port mirroring

Yes

Yes

Yes

  • ? multiport mirroring

Yes

Yes

Yes

  • ? CoS

Yes

Yes

Yes

  • ? PROFINET IO diagnosis

Yes

Yes

Yes

  • ? switch-managed

Yes

Yes

Yes

Protocol is supported

 

 

 

  • ? Telnet

Yes

Yes

Yes

  • ? HTTP

Yes

Yes

Yes

  • ? HTTPS

Yes

Yes

Yes

  • ? TFTP

Yes

Yes

Yes

  • ? FTP

Yes

Yes

Yes

  • ? BOOTP

Yes

Yes

Yes

  • ? GMRP

Yes

Yes

Yes

  • ? DCP

Yes

Yes

Yes

  • ? LLDP

Yes

Yes

Yes

  • ? IGMP (snooping/querier)

Yes

Yes

Yes

Identification & maintenance function

 

 

 

  • ? I&M0 - device-specific information

Yes

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Yes

Protocol is supported

 

 

 

  • ? SNMP v1

Yes

Yes

Yes

  • ? SNMP v2

Yes

Yes

Yes

  • ? SNMP v3

Yes

Yes

Yes

Product functions Diagnosis

 

 

 

Product function

 

 

 

  • ? Port diagnostics

Yes

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

Yes

  • ? Statistics packet type

Yes

Yes

Yes

  • ? Error statistics

Yes

Yes

Yes

  • ? SysLog

Yes

Yes

Yes

Product functions VLAN

 

 

 

Product function

 

 

 

  • ? VLAN - port based

Yes

Yes

Yes

  • ? VLAN - protocol-based

No

No

No

  • ? VLAN - IP-based

No

No

No

  • ? VLAN dynamic

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

Number of VLANs - dynamic maximum

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Product functions DHCP

 

 

 

Product function

 

 

 

  • ? DHCP client

Yes

Yes

Yes

  • ? DHCP Option 82

Yes

Yes

Yes

  • ? DHCP Option 66

Yes

Yes

Yes

  • ? DHCP Option 67

Yes

Yes

Yes

Product functions Redundancy

 

 

 

Product function

 

 

 

  • ? Ring redundancy

Yes

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

Yes

Yes

Yes

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Yes

Product function

 

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

Yes

  • ? redundancy procedure STP

Yes

Yes

Yes

  • ? redundancy procedure RSTP

Yes

Yes

Yes

  • ? redundancy procedure MSTP

Yes

Yes

Yes

  • ? Passive listening

Yes

Yes

Yes

Protocol is supported

 

 

 

  • ? STP/RSTP

Yes

Yes

Yes

  • ? STP

Yes

Yes

Yes

  • ? RSTP

Yes

Yes

Yes

  • ? MSTP

No

No

No

  • ? RSTP big network support

Yes

Yes

Yes

  • ? LACP

Yes

Yes

Yes

Product functions Security

 

 

 

Product function

 

 

 

  • ? ACL - MAC-based

Yes

Yes

Yes

  • ? ACL - port/MAC-based

Yes

Yes

Yes

  • ? IEEE 802.1x (radius)

Yes

Yes

Yes

  • ? Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

  • ? broadcast blocking

Yes

Yes

Yes

Protocol is supported

 

 

 

  • ? SSH

Yes

Yes

Yes

Product functions Time

 

 

 

Product function

 

 

 

  • ? SICLOCK support

Yes

Yes

Yes

Protocol is supported

 

 

 

  • ? NTP

Yes

Yes

Yes

  • ? SNTP

Yes

Yes

Yes

  • ? IEEE 1588 profile default

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

Standard

 

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • ? for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1-03

UL 60950-1, CSA C22.2 No. 60950-1-03

UL 60950-1, CSA C22.2 No. 60950-1-03

  • ? for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • ? for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • ? for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • ? CE marking

Yes

Yes

Yes

  • ? C-Tick

Yes

Yes

Yes

  • ? KC approval

Yes

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

No

Yes

MTBF at 40 °C

25 y

25 y

25 y


Order number

6GK5324-0GG00-3AR2

6GK5324-0GG00-3HR2

Product type designation

SCALANCE XR324-12M

SCALANCE XR324-12M

Transmission rate

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

Interfaces

 

 

Number of electrical/optical connections

 

 

  • ? for network components or terminal equipment maximum

24

24

Type of electrical connection

 

 

  • ? for network components or terminal equipment

Dependent on selected media modules

Dependent on selected media modules

Design of the optical interface

 

 

  • ? for fiber optic cable at 100 Mbit/s

Dependent on selected media modules

Dependent on selected media modules

  • ? for fiber optic cable at 1000 Mbit/s

Dependent on selected media modules

Dependent on selected media modules

Interfaces for communication integrated

 

 

Number of 100 Mbit/s ST(BFOC) ports

 

 

  • ? for multimode

24

24

Number of 100 Mbit/s SC ports

 

 

  • ? for multimode

24

24

Number of 1000 Mbit/s LC ports

 

 

  • ? for multimode

24

24

Interfaces others

 

 

Number of electrical connections

 

 

  • ? for operator console

1

1

  • ? for signaling contact

1

1

  • ? for media module

12

12

  • ? for power supply

1

1

  • ? for redundant voltage supply

0

0

Type of electrical connection

 

 

  • ? for operator console

RJ11 port

RJ11 port

  • ? for signaling contact

2-pole terminal block

2-pole terminal block

  • ? for power supply

2-pole terminal block

2-pole terminal block

design of the removable storage

 

 

  • ? C-PLUG

Yes

Yes

Signal-Inputs/outputs

 

 

Operating voltage of the signaling contacts

 

 

  • ? for DC Rated value

24 V

24 V

Operating current of the signaling contacts

 

 

  • ? for DC maximum

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

Type of voltage supply redundant power supply unit

No

No

Type of voltage of the supply voltage

AC

AC

Supply voltage

 

 

  • ? external

230 V

230 V

  • ? external

85 ... 264 V

85 ... 264 V

Product component fusing at power supply input

Yes

Yes

Fuse protection type at input for supply voltage

3.15 A / 250 V

3.15 A / 250 V

Consumed current maximum

0.8 A

0.8 A

Active power loss

 

 

  • ? with AC at 230 V

50 W

50 W

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • ? during operation

-40 ... +70 °C

-40 ... +70 °C

  • ? during storage

-40 ... +85 °C

-40 ... +85 °C

  • ? during transport

-40 ... +85 °C

-40 ... +85 °C

  • ? Note

Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 °C.

Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 °C.

Relative humidity

 

 

  • ? at 25 °C without condensation during operation maximum

95 %

95 %

Ambient condition

 

 

  • ? for operation

Conformal coating, no

Conformal coating, no

Coating

Conformal Coating, no

Conformal Coating, no

Protection class IP

IP20

IP20

Design, dimensions and weight

 

 

Design

19" rack

19" rack

Number of modular height units relating to 19-inch cabinet

1

1

Width

483 mm

483 mm

Height

44 mm

44 mm

Depth

305 mm

305 mm

Net weight

5.9 kg

5.9 kg

Mounting type

When used in shipbuilding, the device must be secured in the 19" rack at four points

When used in shipbuilding, the device must be secured in the 19" rack at four points

  • ? 19-inch installation

Yes

Yes

  • ? 35 mm DIN rail mounting

No

No

  • ? wall mounting

No

No

  • ? S7-300 rail mounting

No

No

  • ? S7-1500 rail mounting

No

No

Product properties, functions, components general

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

Cascading in cases of star topology

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functions management, configuration

 

 

Product function

 

 

  • ? CLI

Yes

Yes

  • ? web-based management

Yes

Yes

  • ? MIB support

Yes

Yes

  • ? TRAPs via email

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

  • ? RMON

Yes

Yes

  • ? Port mirroring

Yes

Yes

  • ? multiport mirroring

Yes

Yes

  • ? CoS

Yes

Yes

  • ? PROFINET IO diagnosis

Yes

Yes

  • ? switch-managed

Yes

Yes

Protocol is supported

 

 

  • ? Telnet

Yes

Yes

  • ? HTTP

Yes

Yes

  • ? HTTPS

Yes

Yes

  • ? TFTP

Yes

Yes

  • ? FTP

Yes

Yes

  • ? BOOTP

Yes

Yes

  • ? GMRP

Yes

Yes

  • ? DCP

Yes

Yes

  • ? LLDP

Yes

Yes

  • ? IGMP (snooping/querier)

Yes

Yes

Identification & maintenance function

 

 

  • ? I&M0 - device-specific information

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Protocol is supported

 

 

  • ? SNMP v1

Yes

Yes

  • ? SNMP v2

Yes

Yes

  • ? SNMP v3

Yes

Yes

Product functions Diagnosis

 

 

Product function

 

 

  • ? Port diagnostics

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

  • ? Statistics packet type

Yes

Yes

  • ? Error statistics

Yes

Yes

  • ? SysLog

Yes

Yes

Product functions VLAN

 

 

Product function

 

 

  • ? VLAN - port based

Yes

Yes

  • ? VLAN - protocol-based

No

No

  • ? VLAN - IP-based

No

No

  • ? VLAN dynamic

Yes

Yes

Number of VLANs maximum

255

255

Number of VLANs - dynamic maximum

255

255

Protocol is supported GVRP

Yes

Yes

Product functions DHCP

 

 

Product function

 

 

  • ? DHCP client

Yes

Yes

  • ? DHCP Option 82

Yes

Yes

  • ? DHCP Option 66

Yes

Yes

  • ? DHCP Option 67

Yes

Yes

Product functions Redundancy

 

 

Product function

 

 

  • ? Ring redundancy

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

Yes

Yes

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Product function

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

  • ? redundancy procedure STP

Yes

Yes

  • ? redundancy procedure RSTP

Yes

Yes

  • ? redundancy procedure MSTP

Yes

Yes

  • ? Passive listening

Yes

Yes

Protocol is supported

 

 

  • ? STP/RSTP

Yes

Yes

  • ? STP

Yes

Yes

  • ? RSTP

Yes

Yes

  • ? MSTP

No

No

  • ? RSTP big network support

Yes

Yes

  • ? LACP

Yes

Yes

Product functions Security

 

 

Product function

 

 

  • ? ACL - MAC-based

Yes

Yes

  • ? ACL - port/MAC-based

Yes

Yes

  • ? IEEE 802.1x (radius)

Yes

Yes

  • ? Broadcast/Multicast/Unicast Limiter

Yes

Yes

  • ? broadcast blocking

Yes

Yes

Protocol is supported

 

 

  • ? SSH

Yes

Yes

Product functions Time

 

 

Product function

 

 

  • ? SICLOCK support

Yes

Yes

Protocol is supported

 

 

  • ? NTP

Yes

Yes

  • ? SNTP

Yes

Yes

  • ? IEEE 1588 profile default

Yes

Yes

Standards, specifications, approvals

 

 

Standard

 

 

  • ? for FM

no

no

  • ? for hazardous zone

-

-

  • ? for safety from CSA and UL

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

  • ? for hazardous zone from CSA and UL

No

No

  • ? for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • ? for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • ? CE marking

Yes

Yes

  • ? C-Tick

Yes

Yes

  • ? KC approval

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

No

MTBF at 40 °C

15 y

15 y


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2016
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Введение Industrial Ethernet Введение Передача данных Обзор коммуникаций Топологии Критерии выбора типа сети Сетевые компоненты для Industrial Ethernet Промышленные конверторы каналов связи Industrial Ethernet коммутаторы Обзор Компактные коммутаторы CSM Неуправляемые коммутаторы SCALANCE X-000 Неуправляемые коммутаторы/конверторы SCALANCE X-100 Управляемые коммутаторы SCALANCE X-200 Управляемые коммутаторы SCALANCE X-200IRT Управляемые коммутаторы SCALANCE X-300 Управляемые коммутаторы SCALANCE X-300 Коммутаторы SIPLUS SCALANCE X-300 Управляемые коммутаторы SCALANCE X-300EEC Управляемый коммутатор SCALANCE X-300PoE Управляемые коммутаторы SCALANCE XR-300 Управляемые коммутаторы SCALANCE XR-300EEC Управляемый коммутатор SCALANCE XR-300PoE Конвертирующие модули для SCALANCE X-300 Plug-in transceivers for SCALANCE X-300 managed RUGGEDCOM i800 unmanaged or managed RUGGEDCOM RS900 / M900 managed RUGGEDCOM RS950 RNA managed RUGGEDCOM RSG2xxx RUGGEDCOM RSG2100 / M2100 managed RUGGEDCOM RSG2200 / M2200 managed RUGGEDCOM RSG2300 managed RUGGEDCOM RSG2488 managed RUGGEDCOM RS1600 managed RUGGEDCOM RS8000 managed RUGGEDCOM Accessories RUGGEDCOM Technology Modules Коммутаторы Industrial Ethernet уровня 3/ маршрутизаторы Serial Device Servers Аксессуары Активные сетевые компоненты Безопасность передачи данных в промышленных сетях Системные интерфейсы Аксессуары RUGGEDCOM Accessories Управление сетью Сетевые переходы Обслуживание промышленных сетей Решения партнеров PROFINET PROFIBUS AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Информационная безопасность в промышленности Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация и безопасность зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо




  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика