Transmission rate | | |
Transfer rate | | |
| 10 ... 100 Mbit/s | 10 ... 100 Mbit/s |
| 10 ... 100 Mbit/s | 10 ... 100 Mbit/s |
| 9.6 ... 57.6 kbit/s | 9.6 ... 57.6 kbit/s |
Interfaces | | |
Number of electrical connections | | |
| 1 | 1 |
| 1 | 1 |
| 1 | 1 |
| 1 | 1 |
Type of electrical connection | | |
| RJ 45 port | RJ 45 port |
| RJ 45 port | RJ 45 port |
| 2-pole terminal strip | 2-pole terminal strip |
| 3-pole terminal strip | 3-pole terminal strip |
Interfaces wireless | | |
Number of radio cards permanently installed | 1 | 1 |
Number of internal antennas | 1 | 0 |
Number of electrical connections for external antenna(s) | 0 | 1 |
Type of electrical connection for external antenna(s) | - | N-Connector |
Supply voltage, current consumption, power loss | | |
Type of voltage supply | DC | DC |
Supply voltage external | 24 V | 24 V |
Supply voltage external | 20 ... 28 V | 20 ... 28 V |
Consumed current from external supply voltage for DC at 24 V maximum | 0.5 A | 0.5 A |
Active power loss maximum | 12 W | 12 W |
Permitted ambient conditions | | |
Ambient temperature | | |
| -40 ... +70 °C | -40 ... +70 °C |
| -40 ... +85 °C | -40 ... +85 °C |
| -40 ... +85 °C | -40 ... +85 °C |
Relative humidity at 25 °C without condensation during operation maximum | 90 % | 90 % |
Protection class IP | IP 65 | IP 65 |
Design, dimensions and weight | | |
Width of the enclosure | 229 mm | 229 mm |
Height of the enclosure | | |
| 306 mm | 306 mm |
| 354 mm | 354 mm |
Depth of the enclosure | 89 mm | 89 mm |
Net weight | 4.54 kg | 4.54 kg |
Mounting type | Material for mast mounting included in scope of delivery | Material for mast mounting included in scope of delivery |
| Yes | Yes |
| Yes | Yes |
Wireless frequencies | | |
Operating frequency for WirelessHART in 2.4 GHz frequency band | 2.4 ... 2.5 GHz | 2.4 ... 2.5 GHz |
Performance data WirelessHART | | |
Number of WirelessHART devices usable | 100 | 100 |
Network latency | | |
| 10 s | 10 s |
| 5 s | 5 s |
Transmission link between two devices for WirelessHART network maximum | 100 m | 100 m |
| Values may vary in the case of radio obstacles | Values may vary in the case of radio obstacles |
Protocol is supported HART protocol | Yes | Yes |
Product properties, functions, components general | | |
Protocol is supported | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Product functions management, configuration | | |
Product function | | |
| Yes | Yes |
| Yes | Yes |
Product functions Diagnosis | | |
Product function | | |
| Yes | Yes |
| Yes | Yes |
Product functions Redundancy | | |
Product function Device redundancy | No | Yes |
Product functions Security | | |
Product function | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Protocol is supported SSL | Yes | Yes |
Principle of encryption | AES 128 bit | AES 128 bit |
Product functions Time | | |
Protocol is supported NTP | Yes | Yes |
Standards, specifications, approvals | | |
Standard for WirelessHART | HART V 7.1 | HART V 7.1 |
Standard for wireless communication IEEE 802.15.4 | Yes | Yes |
Certificate of suitability | | |
| Yes | Yes |
| CSA Division 2 & Dust Ignition-proof for Class I, Division 2, Groups A, B, C, and D. Dust Ignition-proof for Class II, Groups E, F, and G / Suitable for Class III Hazardous Locations. / Install per Siemens drawing A5E02467236A. Temperature Code: T4 (-40°C < Ta < 60°C) CSA Enclosure Type 4X | CSA Division 2 & Dust Ignition-proof for Class I, Division 2, Groups A, B, C, and D. Dust Ignition-proof for Class II, Groups E, F, and G / Suitable for Class III Hazardous Locations. / Install per Siemens drawing A5E02467236A. Temperature Code: T4 (-40°C < Ta < 60°C) CSA Enclosure Type 4X |
| FM Division 2, Non-Incendive for Class I, Division 2, Groups A, B, C, and D. Dust Ignition-proof for Class II, III, Division 1, Groups E, F, and G / Indoor and outdoor locations / NEMA Type 4X Temperature Code: T4 (-40°C < Ta < 60°C) | FM Division 2, Non-Incendive for Class I, Division 2, Groups A, B, C, and D. Dust Ignition-proof for Class II, III, Division 1, Groups E, F, and G / Indoor and outdoor locations / NEMA Type 4X Temperature Code: T4 (-40°C < Ta < 60°C) |
| ATEX type n, see note: Certificate number: Baseefa10ATEX0044X, ATEX marking: Ex II 3 G, Ex nA nL IIC T4 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V, ATEX dust ignition-proof: Certificate number: Baseefa10ATEX0045X, ATEX marking: II 3 D, Ex tD A22 IP66 T135 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V. Note on type n: Conditions for safe handling during installation. The device does not pass the 500 V insulation test in accordance with paragraph 6.8.1 of EN 60079-15:2005. This must be taken into account when the device is mounted. | ATEX type n, see note: Certificate number: Baseefa10ATEX0044X, ATEX marking: Ex II 3 G, Ex nA nL IIC T4 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V, ATEX dust ignition-proof: Certificate number: Baseefa10ATEX0045X, ATEX marking: II 3 D, Ex tD A22 IP66 T135 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V. Note on type n: Conditions for safe handling during installation. The device does not pass the 500 V insulation test in accordance with paragraph 6.8.1 of EN 60079-15:2005. This must be taken into account when the device is mounted. |
| IECEx Type n, see note: Certificate number: IECEx BAS 10.0014X, Ex nA nL IIC T4 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V, ATEX dust ignition-proof, see note: Certificate number: IECEx BAS 10.0015X, Ex tD A22 IP66 T135 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V. Note on type n: Conditions for safe handling during installation. The device does not pass the 500 V insulation test in accordance with paragraph 6.8.1 of EN 60079-15:2005. This must be taken into account when the device is mounted. | IECEx Type n, see note: Certificate number: IECEx BAS 10.0014X, Ex nA nL IIC T4 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V, ATEX dust ignition-proof, see note: Certificate number: IECEx BAS 10.0015X, Ex tD A22 IP66 T135 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V. Note on type n: Conditions for safe handling during installation. The device does not pass the 500 V insulation test in accordance with paragraph 6.8.1 of EN 60079-15:2005. This must be taken into account when the device is mounted. |
Wireless approval | FCC and IC approval | IC approval |