Suitability for use | Flexible cable for quick assembly, for occasionally moving machine parts | For laying in rail vehicles and buses |
Electrical data | | |
Damping ratio per length | | |
| 89 dB/km | 63 dB/km |
| 287 dB/km | 207 dB/km |
| 466 dB/km | 343 dB/km |
| 0.514 dB/m | |
Impedance | | |
| 100 ? | 100 ? |
Relative symmetrical tolerance | | |
| | 5 % |
Near-end crosstalk per length | | |
| 0.453 dB/m | |
| 393 dB/km | |
| 0.381 dB/m | |
Transfer impedance per length at 10 MHz | 20 m?/m | 5 m?/m |
Loop resistance per length maximum | 180 ?/km | 124 ?/km |
Insulation resistance coefficient | 5 000 G?·m | 5 000 G?·m |
Operating voltage | | |
| 100 V | 125 V |
NVP value in percent | 68 % | |
Mechanical data | | |
Number of electrical cores | 8 | 8 |
Design of the shield | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | Overlapped aluminum-clad foil, sheathed in a protective braided shield of tin-plated copper wires with additional pair shielding |
Type of electrical connection FastConnect | Yes | No |
Core diameter | | |
| 0.51 mm | 0.51 mm |
Outer diameter | | |
| 0.6 mm | |
| 1.05 mm | 1.5 mm |
| 6.4 mm | |
| 8 mm | 8.8 mm |
Symmetrical tolerance of the outer diameter of cable sheath | 0.2 mm | 0.2 mm |
Material | | |
| PE | PE |
| FRNC | |
| PVC | Elastomer meshed electron beam |
Color | | |
| white-blue/blue, white-orange/orange, white-green/green, white-brown/brown | white/blue, white/green, white/brown, white/orange |
| green | Black |
Bending radius | | |
| 24 mm | 53 mm |
| 40 mm | 53 mm |
Tensile load maximum | 100 N | 100 N |
Weight per length | 86 kg/km | 79 kg/km |
Permitted ambient conditions | | |
Ambient temperature | | |
| -40 ... +80 °C | -40 ... +80 °C |
| -40 ... +80 °C | -40 ... +80 °C |
| -40 ... +80 °C | -40 ... +80 °C |
| -40 ... +80 °C | -20 ... +60 °C |
Burning behavior | flame resistant according to IEC 60332-3-24 (Category C) | BS 6853, DIN5510-2 Brandschutzstufe 1-4, prEN 45545-2 Hazard Level HL 1-HL 3, EN 50306-4, NF F 16-101, NFPA130 |
Chemical resistance | | |
| oil resistant according to IEC 60811-2-1 (4 h / 70°C) | EN 50306-4 (72h/100 °C, IRM 902, 168h/70 °C, IRM 903) |
| Conditional resistance | Conditional resistance |
| Conditional resistance | Conditional resistance |
Radiological resistance to UV radiation | resistant | resistant |
Product properties, functions, components general | | |
Product property | | |
| No | Yes |
| Yes | Yes |
Cable length for Industrial Ethernet | | |
| 80 m | 100 m |
| 80 m | 100 m |
Standards, specifications, approvals | | |
Certificate of suitability | | |
| Yes | Yes |
| Yes | Yes |
Standard for structured cabling | Cat6A | Cat7 |
Marine classification association | | |
| No | No |
| No | No |
| No | No |
| No | No |
| No | No |
| No | No |
| No | No |