Transmission rate | | |
Transfer rate | 100 Mbit/s | 100 Mbit/s |
Interfaces | | |
Number of electrical/optical connections for network components or terminal equipment maximum | 2 | 2 |
Number of electrical connections | | |
| 1 | 1 |
| 1 | 1 |
| 1 | 1 |
| 1 | 1 |
Type of electrical connection | | |
| RJ45 port | RJ45 port |
| 2-pole terminal block | 2-pole terminal block |
| 4-pole terminal block | 4-pole terminal block |
Number of optical interfaces | | |
| 1 | 1 |
Design of the optical interface | | |
| BFOC-Port (Multimode up to 5 km) | ST/SC-Port |
Connectable optical power relative to 1 mW | | |
| -19 dB | -5 dB |
| -14 dB | 0 dB |
| -14 dB | 0 dB |
Optical sensitivity relating to 1 mW of the receiver input minimum | -31 dB | -35 dB |
Damping ratio of the FOC transmission link minimum necessary | 0 dB | 0 dB |
Range at the optical interface depending on the optical fiber used | 0 ... 5 km | 0 ... 26 km |
Signal-Inputs/outputs | | |
Operating voltage of the signaling contacts | | |
| 24 V | 24 V |
Operating current of the signaling contacts | | |
| 0.1 A | 0.1 A |
Supply voltage, current consumption, power loss | | |
Supply voltage | | |
| 24 V | 24 V |
| 18 ... 32 V | 18 ... 32 V |
Type of voltage of the supply voltage | DC | DC |
Product component fusing at power supply input | Yes | Yes |
Fuse protection type at input for supply voltage | 0.5 A / 60 V | 0.5 A / 60 V |
Consumed current | | |
| 0.12 A | 0.12 A |
Active power loss | | |
| 3 W | 3 W |
Permitted ambient conditions | | |
Ambient temperature | | |
| -10 ... +60 °C | -10 ... +60 °C |
| -40 ... +80 °C | -40 ... +80 °C |
| -40 ... +80 °C | -40 ... +80 °C |
Relative humidity at 25 °C without condensation during operation maximum | 95 % | 95 % |
Protection class IP | IP30 | IP30 |
Design, dimensions and weight | | |
Design | Compact | Compact |
Width | 40 mm | 40 mm |
Height | 125 mm | 125 mm |
Depth | 124 mm | 124 mm |
Net weight | 550 g | 550 g |
Mounting type | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Product properties, functions, components general | | |
Product function Parallel Redundancy Protocol (PRP) | No | No |
Standards, specifications, approvals | | |
Standard | | |
| FM3611: Class 1, Divison 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. | FM3611: Class 1, Divison 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
| EN 600079-15 II 3 G EEx nA II T.. KEMA 06 ATEX 0021 X | EN 600079-15 II 3 G EEx nA II T.. KEMA 06 ATEX 0021 X |
| UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 |
| UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
| EN 61000-6-3 | EN 61000-6-4:2001 |
| EN 61000-6-4:2001 | EN 61000-6-4:2001 |
Certificate of suitability | EN 61000-6-2:2001, EN 61000-6-4:2001 | EN 61000-6-2:2001, EN 61000-6-4:2001 |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Marine classification association | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| No | No |
MTBF at 40 °C | 134 y | 134 y |