Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2016
архивный
(4872) 700-366
skenergo@mail.ru

Оптические модули связи SIPLUS OLM

Order number

6GK1503-2CA00

6GK1503-3CA00

6GK1503-4CA00

Product type designation

PROFIBUS OLM P11

PROFIBUS OLM P12

PROFIBUS OLM P22

Transmission rate

 

 

 

Transfer rate with PROFIBUS

9.6 kbit/s ... 12 Mbit/s

9.6 kbit/s ... 12 Mbit/s

9.6 kbit/s ... 12 Mbit/s

Transfer rate with PROFIBUS PA

45.45 kbit/s

45.45 kbit/s

45.45 kbit/s

Interfaces

 

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

2

3

4

Number of electrical connections

 

 

 

  • ? for network components or terminal equipment

1

1

2

  • ? for measuring device

1 1

1 1

1 1

  • ? for signaling contact

1

1

1

  • ? for power supply

1

1

1

  • ? for redundant voltage supply

1

1

1

Type of electrical connection

 

 

 

  • ? for network components or terminal equipment

9-pin Sub-D socket

9-pin Sub-D socket

9-pin Sub-D socket

  • ? for measuring device

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • ? for power supply

-

-

-

  • ? for power supply and signaling contact

5-pole terminal block

5-pole terminal block

5-pole terminal block

Number of optical interfaces for fiber optic cable

1

2

2

Design of the optical interface for fiber optic cable

BFOC port

BFOC port

BFOC port

Optical data

 

 

 

Damping ratio of the FOC transmission link

 

 

 

  • ? for POF FOC with 980/1000 µm at 230 dB/km

13 dB

13 dB

13 dB

propagation delay [bit]

6.5 bit

6.5 bit

6.5 bit

Connectable optical power relative to 1 mW

 

 

 

  • ? of the FOC transmission link for PCF FOC with 200/230 µm at 10 dB/km

-17 dB

-17 dB

-17 dB

  • ? of the FOC transmission link for POF FOC with 980/1000 µm at 230 dB/km

-5 dB

-5 dB

-5 dB

Optical sensitivity relating to 1 mW

 

 

 

  • ? of the FOC transmission link for PCF FOC with 200/230 µm at 10 dB/km

-25 dB

  • ? of the FOC transmission link for POF FOC with 980/1000 µm at 230 dB/km

-25 dB

Wavelength

 

 

 

  • ? of the FOC transmission link for PCF FOC with 200/230 µm at 10 dB/km

660 nm

660 nm

660 nm

  • ? of the FOC transmission link for POF FOC with 980/1000 µm at 230 dB/km

660 nm

660 nm

660 nm

Cable length

 

 

 

  • ? for PCF FOC with 200/230 µm at 10 dB/km maximum

400 m

400 m

400 m

  • ? for POF FOC with 980/1000 µm at 230 dB/km maximum

80 m

80 m

80 m

Signal-Inputs/outputs

 

 

 

Operating voltage of the signaling contacts for DC Rated value

24 V

24 V

24 V

Operating current of the signaling contacts for DC maximum

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

Type of voltage of the supply voltage

DC

DC

DC

Supply voltage for DC Rated value

24 V

24 V

24 V

Supply voltage for DC

18.8 ... 28.8 V

18.8 ... 28.8 V

18.8 ... 28.8 V

Product component fusing at power supply input

Yes

Yes

Yes

Consumed current for DC at 24 V maximum

0.2 A

0.2 A

0.2 A

Permitted ambient conditions

 

 

 

Ambient temperature

 

 

 

  • ? during operation

0 ... 60 °C

0 ... 60 °C

0 ... 60 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

Relative humidity at 25 °C without condensation during operation maximum

95 %

95 %

95 %

Protection class IP

IP40

IP40

IP40

Design, dimensions and weight

 

 

 

Design

compact

compact

compact

Width

39.5 mm

39.5 mm

39.5 mm

Height

112 mm

112 mm

112 mm

Depth

74.5 mm

74.5 mm

74.5 mm

Net weight

340 g

340 g

340 g

Mounting type

 

 

 

  • ? 35 mm DIN rail mounting

Yes

Yes

Yes

  • ? wall mounting

Yes

Yes

Yes

Product functions Redundancy

 

 

 

Product function Ring redundancy

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

Standard

 

 

 

  • ? for FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • ? for hazardous zone

EN 60079-0: 2006, EN60079-15: 2005, EN60079-28: 2007, II 3 (2) G Ex nA [opis] IIC T4 KEMA 09 ATEX 0173X

EN 60079-0: 2006, EN60079-15: 2005, EN60079-28: 2007, II 3 (2) G Ex nA [opis] IIC T4 KEMA 09 ATEX 0173X

EN 60079-0: 2006, EN60079-15: 2005, EN60079-28: 2007, II 3 (2) G Ex nA [opis] IIC T4 KEMA 09 ATEX 0173X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 Nr. 60950-1

UL 60950-1, CSA C22.2 Nr. 60950-1

UL 60950-1, CSA C22.2 Nr. 60950-1

  • ? for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • ? for emitted interference

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

  • ? for interference immunity

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

Certificate of suitability

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

  • ? CE marking

Yes

Yes

Yes

  • ? C-Tick

Yes

Yes

Yes

Marine classification association

 

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

  • ? Bureau Veritas (BV)

Yes

Yes

Yes

  • ? Det Norske Veritas (DNV)

Yes

Yes

Yes

  • ? Germanische Lloyd (GL)

Yes

Yes

Yes

  • ? Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

  • ? Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes


Order number

6GK1503-2CB00

6GK1503-3CB00

6GK1503-4CB00

Product type designation

PROFIBUS OLM G11

PROFIBUS OLM G12

PROFIBUS OLM G22

Transmission rate

 

 

 

Transfer rate with PROFIBUS

9.6 kbit/s ... 12 Mbit/s

9.6 kbit/s ... 12 Mbit/s

9.6 kbit/s ... 12 Mbit/s

Transfer rate with PROFIBUS PA

45.45 kbit/s

45.45 kbit/s

45.45 kbit/s

Interfaces

 

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

2

3

4

Number of electrical connections

 

 

 

  • ? for network components or terminal equipment

1

1

2

  • ? for measuring device

1 1

1 1

1 1

  • ? for signaling contact

1

1

1

  • ? for power supply

1

1

1

  • ? for redundant voltage supply

1

1

1

Type of electrical connection

 

 

 

  • ? for network components or terminal equipment

9-pin Sub-D socket

9-pin Sub-D socket

9-pin Sub-D socket

  • ? for measuring device

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • ? for power supply

-

-

-

  • ? for power supply and signaling contact

5-pole terminal block

5-pole terminal block

5-pole terminal block

Number of optical interfaces for fiber optic cable

1

2

2

Design of the optical interface for fiber optic cable

BFOC port

BFOC port

BFOC port

Optical data

 

 

 

Damping ratio of the FOC transmission link

 

 

 

  • ? for glass FOC with 50/125 µm at 3 dB/km maximum

10 dB

10 dB

10 dB

  • ? for glass FOC with 62.5/125 µm at 3.5 dB/km maximum

12 dB

12 dB

12 dB

propagation delay [bit]

6.5 bit

6.5 bit

6.5 bit

Connectable optical power relative to 1 mW

 

 

 

  • ? for glass FOC with 50/125 µm at 3 dB/km

-16 dB

-16 dB

-16 dB

  • ? for glass FOC with 62.5/125 µm at 3.5 dB/km

-13 dB

-13 dB

-13 dB

Optical sensitivity relating to 1 mW

 

 

 

  • ? for glass FOC with 50/125 µm at 3 dB/km

-28 dB

-28 dB

-28 dB

  • ? for glass FOC with 62.5/125 µm at 3.5 dB/km

-28 dB

-28 dB

-28 dB

Wavelength

 

 

 

  • ? for glass FOC with 50/125 µm compatible with interface at 3 dB/km

860 nm

860 nm

860 nm

  • ? for glass FOC with 62.5/125 µm compatible with interface at 3.5 dB/km

860 nm

860 nm

860 nm

Cable length

 

 

 

  • ? for glass FOC with 50/125 µm at 3 dB/km maximum

3 km

3 km

3 km

  • ? for glass FOC with 62.5/125 µm at 3.5 dB/km maximum

3 km

3 km

3 km

Signal-Inputs/outputs

 

 

 

Operating voltage of the signaling contacts for DC Rated value

24 V

24 V

24 V

Operating current of the signaling contacts for DC maximum

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

Type of voltage of the supply voltage

DC

DC

DC

Supply voltage for DC Rated value

24 V

24 V

24 V

Supply voltage for DC

18.8 ... 28.8 V

18.8 ... 28.8 V

18.8 ... 28.8 V

Product component fusing at power supply input

Yes

Yes

Yes

Consumed current for DC at 24 V maximum

0.2 A

0.2 A

0.2 A

Permitted ambient conditions

 

 

 

Ambient temperature

 

 

 

  • ? during operation

0 ... 60 °C

0 ... 60 °C

0 ... 60 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

Relative humidity at 25 °C without condensation during operation maximum

95 %

95 %

95 %

Protection class IP

IP40

IP40

IP40

Design, dimensions and weight

 

 

 

Design

compact

compact

compact

Width

39.5 mm

39.5 mm

39.5 mm

Height

112 mm

112 mm

112 mm

Depth

74.5 mm

74.5 mm

74.5 mm

Net weight

340 g

340 g

340 g

Mounting type

 

 

 

  • ? 35 mm DIN rail mounting

Yes

Yes

Yes

  • ? wall mounting

Yes

Yes

Yes

Product functions Redundancy

 

 

 

Product function Ring redundancy

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

Standard

 

 

 

  • ? for FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • ? for hazardous zone

EN 60079-0: 2006, EN60079-15: 2005, EN60079-28: 2007, II 3 (2) G Ex nA [opis] IIC T4 KEMA 09 ATEX 0173X

EN 60079-0: 2006, EN60079-15: 2005, EN60079-28: 2007, II 3 (2) G Ex nA [opis] IIC T4 KEMA 09 ATEX 0173X

EN 60079-0: 2006, EN60079-15: 2005, EN60079-28: 2007, II 3 (2) G Ex nA [opis] IIC T4 KEMA 09 ATEX 0173X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 Nr. 60950-1

UL 60950-1, CSA C22.2 Nr. 60950-1

UL 60950-1, CSA C22.2 Nr. 60950-1

  • ? for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • ? for emitted interference

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

  • ? for interference immunity

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

Certificate of suitability

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

  • ? CE marking

Yes

Yes

Yes

  • ? C-Tick

Yes

Yes

Yes

Marine classification association

 

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

  • ? Bureau Veritas (BV)

Yes

Yes

Yes

  • ? Det Norske Veritas (DNV)

Yes

Yes

Yes

  • ? Germanische Lloyd (GL)

Yes

Yes

Yes

  • ? Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

  • ? Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes


Order number

6GK1503-2CC00

6GK1503-3CC00

6GK1503-3CD00

Product type designation

PROFIBUS OLM G11-1300

PROFIBUS OLM G12-1300

PROFIBUS OLM G12 EEC

Transmission rate

 

 

 

Transfer rate with PROFIBUS

9.6 kbit/s ... 12 Mbit/s

9.6 kbit/s ... 12 Mbit/s

9.6 kbit/s ... 12 Mbit/s

Transfer rate with PROFIBUS PA

45.45 kbit/s

45.45 kbit/s

45.45 kbit/s

Interfaces

 

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

2

3

3

Number of electrical connections

 

 

 

  • ? for network components or terminal equipment

1

1

1

  • ? for measuring device

1 1

1 1

1 1

  • ? for signaling contact

1

1

1

  • ? for power supply

1

1

1

  • ? for redundant voltage supply

1

1

1

Type of electrical connection

 

 

 

  • ? for network components or terminal equipment

9-pin Sub-D socket

9-pin Sub-D socket

9-pin Sub-D socket

  • ? for measuring device

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • ? for power supply

-

-

-

  • ? for power supply and signaling contact

5-pole terminal block

5-pole terminal block

5-pole terminal block

Number of optical interfaces for fiber optic cable

1

2

2

Design of the optical interface for fiber optic cable

BFOC port

BFOC port

BFOC port

Optical data

 

 

 

Damping ratio of the FOC transmission link

 

 

 

  • ? for glass FOC with 10/125 µm or 9/125 µm at 0.5 dB/km maximum

8 dB

8 dB

  • ? for glass FOC with 50/125 µm at 3 dB/km maximum

10 dB

  • ? for glass FOC with 62.5/125 µm at 3.5 dB/km maximum

12 dB

propagation delay [bit]

6.5 bit

6.5 bit

6.5 bit

Connectable optical power relative to 1 mW

 

 

 

  • ? for glass FOC with 10/125 µm or 9/125 µm at 0.5 dB/km

-19 dB

-19 dB

  • ? for glass FOC with 50/125 µm at 3 dB/km

-16 dB

  • ? for glass FOC with 62.5/125 µm at 3.5 dB/km

-13 dB

Optical sensitivity relating to 1 mW

 

 

 

  • ? for glass FOC with 10/125 µm or 9/125 µm at 0.5 dB/km

-29 dB

-29 dB

  • ? for glass FOC with 50/125 µm at 3 dB/km

-28 dB

  • ? for glass FOC with 62.5/125 µm at 3.5 dB/km

-28 dB

Wavelength

 

 

 

  • ? for glass FOC with 10/125 µm or 9/125 µm compatible with interface at 0.5 dB/km

1 310 nm

1 310 nm

  • ? for glass FOC with 50/125 µm compatible with interface at 3 dB/km

860 nm

  • ? for glass FOC with 62.5/125 µm compatible with interface at 3.5 dB/km

860 nm

Cable length

 

 

 

  • ? for glass FOC with 10/125 µm or 9/125 µm at 0.5 dB/km maximum

15 km

15 km

  • ? for glass FOC with 50/125 µm at 3 dB/km maximum

3 km

  • ? for glass FOC with 62.5/125 µm at 3.5 dB/km maximum

3 km

Signal-Inputs/outputs

 

 

 

Operating voltage of the signaling contacts for DC Rated value

24 V

24 V

24 V

Operating current of the signaling contacts for DC maximum

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

Type of voltage of the supply voltage

DC

DC

DC

Supply voltage for DC Rated value

24 V

24 V

24 V

Supply voltage for DC

18.8 ... 28.8 V

18.8 ... 28.8 V

18.8 ... 28.8 V

Product component fusing at power supply input

Yes

Yes

Yes

Consumed current for DC at 24 V maximum

0.2 A

0.2 A

0.2 A

Permitted ambient conditions

 

 

 

Ambient temperature

 

 

 

  • ? during operation

0 ... 60 °C

0 ... 60 °C

-25 ... +60 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

Relative humidity at 25 °C without condensation during operation maximum

95 %

95 %

95 %

Protection class IP

IP40

IP40

IP40

Design, dimensions and weight

 

 

 

Design

compact

compact

compact

Width

39.5 mm

39.5 mm

39.5 mm

Height

112 mm

112 mm

112 mm

Depth

74.5 mm

74.5 mm

74.5 mm

Net weight

340 g

340 g

340 g

Mounting type

 

 

 

  • ? 35 mm DIN rail mounting

Yes

Yes

Yes

  • ? wall mounting

Yes

Yes

Yes

Product functions Redundancy

 

 

 

Product function Ring redundancy

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

Standard

 

 

 

  • ? for FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • ? for hazardous zone

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0003X

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0003X

EN 60079-0: 2006, EN60079-15: 2005, EN60079-28: 2007, II 3 (2) G Ex nA [opis] IIC T4 KEMA 09 ATEX 0173X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 Nr. 60950-1

UL 60950-1, CSA C22.2 Nr. 60950-1

UL 60950-1, CSA C22.2 Nr. 60950-1

  • ? for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • ? for emitted interference

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

  • ? for interference immunity

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

Certificate of suitability

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

  • ? CE marking

Yes

Yes

Yes

  • ? C-Tick

Yes

Yes

Yes

Marine classification association

 

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

  • ? Bureau Veritas (BV)

Yes

Yes

Yes

  • ? Det Norske Veritas (DNV)

Yes

Yes

Yes

  • ? Germanische Lloyd (GL)

Yes

Yes

Yes

  • ? Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

  • ? Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2016
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Модули с расширенным температурным диапазоном SIPLUS Промышленные системы автоматизации SIMATIC Распределенные системы управления Системы оперативного управления и мониторинга Промышленные коммуникации SIPLUS Industrial Ethernet SIPLUS PROFIBUS Системные интерфейсы SIPLUS Оптические модули SIPLUS OLM Оптические модули связи SIPLUS OLM SIPLUS AS-Interface SIPLUS Telecontrol Аппаратура управления Блоки питания Дополнения SIPLUS Test Системы телеметрии IO Systems for heating units Automatic door controls Condition monitoring systems Автоматизация и безопасность зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо




  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика