Suitability for operation | PROFINET network together with RF200/300/600, MOBY D/E/I/U, MV | Industrial Ethernet Netzwerk together with RF200/300/600, MOBY D/U | Ethernet/IP Netzwerk together with RF200/300/600, MOBY D/E/I/U, MV |
Transmission rate | | | |
Transfer rate for Industrial Ethernet | 10 ... 100 Mbit/s | 10 ... 100 Mbit/s | 10 ... 100 Mbit/s |
Transfer rate at the point-to-point connection serial maximum | 115.2 kbit/s | 115.2 kbit/s | 115.2 kbit/s |
Interfaces | | | |
Design of the interface for point-to-point connection | RS422 | RS422 | RS422 |
Number of readers connectable | 2 | 2 | 2 |
Type of electrical connection | | | |
| (according to the connection block) | (according to the connection block) | (according to the connection block) |
| (according to the connection block) | (according to the connection block) | (according to the connection block) |
Design of the interface to the reader for communication | M12, 8-pin | M12, 8-pin | M12, 8-pin |
Mechanical data | | | |
Material | Thermoplastic (Valox 467, fiberglass reinforced) | Thermoplastic (Valox 467, fiberglass reinforced) | Thermoplastic (Valox 467, fiberglass reinforced) |
Color | IP Basic 714 | IP Basic 714 | IP Basic 714 |
Tightening torque of the screw for securing the equipment maximum | 3 N·m | 3 N·m | 3 N·m |
Supply voltage, current consumption, power loss | | | |
Supply voltage | | | |
| 24 V | 24 V | 24 V |
| 20 ... 30 V | 20 ... 30 V | 20 ... 30 V |
Consumed current for DC at 24 V | | | |
| 0.1 A | 0.1 A | 0.1 A |
| 1.1 A | 1.1 A | 1.1 A |
Permitted ambient conditions | | | |
Ambient temperature | | | |
| 0 ... 60 °C | 0 ... 60 °C | 0 ... 60 °C |
| -40 ... +70 °C | -40 ... +70 °C | -40 ... +70 °C |
| -40 ... +70 °C | -40 ... +70 °C | -40 ... +70 °C |
Protection class IP | IP67 | IP67 | IP67 |
Shock resistance | According to IEC 61131-2 | According to IEC 61131-2 | According to IEC 61131-2 |
Shock acceleration | 300 m/s? | 300 m/s? | 300 m/s? |
Resistance against vibration | 100 m/s? | 100 m/s? | 100 m/s? |
Design, dimensions and weight | | | |
Width | 60 mm | 60 mm | 60 mm |
Height | 30 mm | 30 mm | 30 mm |
Depth | 210 mm | 210 mm | 210 mm |
Net weight | 0.21 kg | 0.21 kg | 0.21 kg |
Mounting type | 2 x M5 screws | 2 x M5 screws | 2 x M5 screws |
Cable length for RS 422 interface maximum | 1 000 m | 1 000 m | 1 000 m |
Product properties, functions, components general | | | |
Display version | 4 LEDs per reader connection, 4 LEDs for device status | 4 LEDs per reader connection, 4 LEDs for device status | 4 LEDs per reader connection, 4 LEDs for device status |
Protocol is supported Media Redundancy Protocol (MRP) | No | No | No |
Product function transponder file handler can be addressed | Yes | No | Yes |
Protocol is supported | | | |
| Yes | No | No |
| Yes | No | No |
| No | Yes | No |
| No | No | Yes |
Type of parameterization | GSDML | XML | EDS file |
Type of programming | FB 45, FB 55, Ident profile (PIB) | XML commands | Data records via implicit/explicit messages |
Type of computer-mediated communication | acyclic communication | XML | Implicit/explicit messaging |
Standards, specifications, approvals | | | |
Certificate of suitability | CE, FCC, cULus, PNO: Conformance Class B | CE, FCC, cULus | CE, FCC, cULus |
MTBF | 121 y | 121 y | 121 y |
Accessories | | | |
accessories | Connection block M12 d-coded, 7/8'' 5-pin or push-pull | Connection block M12 d-coded, 7/8'' 5-pin or push-pull or M12 d-coded, 7/8'' 4-pin | Connection block M12 d-coded, 7/8'' 5-pin or push-pull or M12 d-coded, 7/8'' 4-pin |