Suitability for operation | ISO 15693 Transponder (MDS Dxxx), for connecting to PC systems | ISO 15693 Transponder (MDS Dxxx), for connecting to communication modules | ISO 15693 Transponder (MDS Dxxx), for connecting to communication modules |
Wireless frequencies | | | |
Operating frequency Rated value | 13.56 MHz | 13.56 MHz | 13.56 MHz |
Electrical data | | | |
Range maximum | 220 mm; Range is dependent on transponder type: observe http://support.automation.siemens.com/WW/view/en/67384964 | 220 mm; Range is dependent on transponder type: observe http://support.automation.siemens.com/WW/view/en/67384964 | 220 mm; Range is dependent on transponder type: observe http://support.automation.siemens.com/WW/view/en/67384964 |
Protocol with radio transmission | ISO 15693, ISO 18000-3 | ISO 15693, ISO 18000-3 | ISO 15693, ISO 18000-3 |
Transfer rate with radio transmission maximum | 26.5 kbit/s | 26.5 kbit/s | 26.5 kbit/s |
Product property multitag-capable | Yes | No | No |
Transfer rate at the point-to-point connection serial maximum | 38.4 kbit/s | 19.2 kbit/s | 19.2 kbit/s |
Transmission time for user data | | | |
| 2.5 ms | 2.5 ms | 2.5 ms |
| 2.5 ms | 2.5 ms | 2.5 ms |
Interfaces | | | |
Standard for interfaces for communication | RS232 | RS422 | RS422 |
Type of electrical connection | Data: Sub-D, 9-pin, male, voltage: M12, 4-pin, female connector | Data: Sub-D, 9-pin, male, voltage: M12, 4-pin, female connector | M12, 8-pin |
Mechanical data | | | |
Material | PA 12 | PA 12 | PA 12 |
Color | anthracite | anthracite | anthracite |
Tightening torque of the screw for securing the equipment maximum | 2 N·m | 2 N·m | 2 N·m |
Mounting distance relating to metal surfaces recommended minimum | 0 mm | 0 mm | 0 mm |
Supply voltage, current consumption, power loss | | | |
Supply voltage | | | |
| 24 V | 24 V | 24 V |
| 20 ... 30 V | 20 ... 30 V | 20 ... 30 V |
Consumed current for DC at 24 V | | | |
| 0.15 A | 0.15 A | 0.15 A |
| 0.6 A | 0.6 A | 0.6 A |
Permitted ambient conditions | | | |
Ambient temperature | | | |
| -25 ... +55 °C | -25 ... +55 °C | -25 ... +55 °C |
| -25 ... +70 °C | -25 ... +70 °C | -25 ... +70 °C |
| -25 ... +70 °C | -25 ... +70 °C | -25 ... +70 °C |
Protection class IP | IP65 | IP65 | IP65 |
Shock resistance | EN 60721-3-7 Class 7 M2 | EN 60721-3-7 Class 7 M2 | EN 60721-3-7 Class 7 M2 |
Shock acceleration | 300 m/s? | 300 m/s? | 300 m/s? |
Resistance against vibration | 15 m/s? | 15 m/s? | 15 m/s? |
Design, dimensions and weight | | | |
Width | 80 mm | 80 mm | 80 mm |
Height | 40 mm | 40 mm | 40 mm |
Depth | 160 mm | 160 mm | 160 mm |
Net weight | 0.23 kg | 0.23 kg | 0.23 kg |
Mounting type | 2 x M5 screws | 2 x M5 screws | 2 x M5 screws |
Cable length | | | |
| 30 m | | |
| | 300 m | 300 m |
Product properties, functions, components general | | | |
Display version | - | - | - |
Standards, specifications, approvals | | | |
Certificate of suitability | CE, FCC, IC (Canada), UL 60950, safe for cardiac pacemakers | CE, FCC, IC (Canada), UL 60950, safe for cardiac pacemakers | CE, FCC, IC (Canada), UL 60950, safe for cardiac pacemakers |
MTBF | 23 y | 23 y | 23 y |