SIMATIC NET IE SOFTNET-S7/2008 CD С ПРОГР. ОБЕСП. ДЛЯ S7-, S5-СОВМ.-КОММУН.,OPC, PG/OP-КОММУН.,NCM PC, ДО 64 СОЕДИНЕНИЙ, ОДНА ЛИЦЕНЗИЯ ДЛЯ УСТАНОВКИ, ПРОГРАММНОЕ ОБЕСПЕЧЕНИЕ + ДОКУМЕНТ. НА CD, ЛИЦЕНЗИЯ НА USB-НАКОПИТЕЛЕ, 2-ЯЗЫКА. (Н,А); ДЛЯ 32БИТ WINDOWS
1176.60 ?
SIPLUS CP 443-2 Advanced
Connection of SIMATIC S7-400 to Industrial Ethernet
Multi-protocol operation for ISO, TCP/IP, UDP and PROFINET IO protocols
Adjustable keep-alive function
Two separate interfaces (integrated network separation):
Gigabit interface with one RJ45 port with 10/100/1 000 Mbit/s, full/half-duplex with auto-sensing capability
PROFINET interface with four RJ45 ports with 10/100 Mbit/s, full/half duplex with autosensing and autocrossover functionality via integrated 4-port switch
Communications services via both interfaces
Open communication (ISO, TCP/IP and UDP), multicast with UDP, including routing between both interfaces
PG/OP communication: Cross-network by means of S7 routing
S7 communication (client, server, multiplexing) including routing between both interfaces
IT communication: HTTP communication supports access to process data via own Web pages; e-mail client function, sending of e-mails with authentication directly from user program; FTP communication supports program-controlled FTP client communication; access to data blocks through FTP server
Communications services via PROFINET interface
PROFINET IO controller with real-time properties (RT and IRT)
PROFINET CBA
IP address assignment via DHCP, simple PC tool or via the user program (e.g. HMI)
Support of the prioritized startup of PROFINET IO devices
Configuration with STEP 7
Media redundancy (MRP); the CP supports the media redundancy procedure MRP within an Ethernet network with ring topology.
Access protection by means of configurable IP access list
Module replacement without programming device; all information is stored on the C-PLUG (also file system for IT functions)
Extensive diagnostic functions for all modules in the rack
Integration into network management systems through the support of SNMP V1 MIB-II
Operation in the SIMATIC H system for redundant S7-communication
Operation in fail-safe applications (PROFIsafe) in combination with SIMATIC S7-400 CPU 416F
Note:
SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme specific information was added.
SIPLUS CP 443-1 Advanced
Article No.
6AG1443-1GX30-4XE0
Order number based on
6GK7443-1GX30-0XE0
Ambient temperature range
0 ... +60 °C
Conformal coating
Coating of the printed circuit boards and the electronic components
Technical data
The technical data of the standard product applies, except for the ambient conditions
Ambient conditions
Relative humidity
100%, condensation/frost permitted. No commissioning in bedewed state.
Biologically active substances, compliance with EN 60721-3-3
Class 3B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!
Chemically active substances, compliance with EN 60721-3-3
Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3). The supplied plug covers must remain in place over the unused interfaces during operation!
Mechanically active substances, compliance with EN 60721-3-3
Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation!
Air pressure (depending on the highest positive temperature range specified)
1 080 ... 795 hPa (-1 000 ... +2 000 m) see ambient temperature range
795 ... 658 hPa (+2 000 ... +3 500 m) derating 10 K
658 ... 540 hPa (+3 500 ... +5 000 m) derating 20 K