Power unit
- Complies with EMC guidelines defined in EN 61800?3 thanks to line filter which is integrated as standard (with grounded supply system)
- Category C2 for compact units in TN/TT system of the first environment (residential area), category C1 available as an option
- Category C3 for cabinet units (TN/TT system) of the second environment (industrial area)
- Category C4 for compact and cabinet units in IT system of the second environment (industrial area)
- SINAMICS G180 converters cause minor line harmonics: Thanks to line reactors integrated in cabinet units and DC reactors integrated in compact units
- Output filter to permit the use of long motor cables for motors with standard insulation
- Insulation monitoring for IT systems integrated in 500/690 V units and ground fault monitoring for TN and TT systems integrated in 400 V units
- Wide range of input voltages
- Lower additional motor noise emissions of typically 3 dB(A) as well as minor losses in converter and motor thanks to optimized pulse pattern and converter clock frequency
- Units can be protected by standard fuses (gL characteristic)
- Standardized user interface on units rated from 2.2 to 6 600 kW
Control section
- High level of protection for personnel and plant is provided by protective separation of the safety extra-low voltage in accordance with IEC/EN 61800?5?1 at the analog and digital control inputs and outputs of the power unit.
Operation and settings
- Straightforward to operate and set by means of a menu-assisted, 4-line plaintext display with membrane keyboard on the converter unit or remotely from the control room via an RS485 link at a distance of up to 1000 m
- Extensive range of functions using a Windows-based PC operating program
Explosion protection
- ATEX-certified tripping concept in accordance with Directive 94/9 EC for the safe operation of motors in hazardous zones 1 and 2, which means that no main contactor is required
Safe Torque Off
Available with options G04, G05, G08
- Shutdown mechanism to prevent unexpected starting. Category 0 stop function in accordance with EN 60204?1 (stop by disconnection of power supply to the machine).
- Functional safety in accordance with:
- SIL 2 as per EN 61508
- Category 3 to EN ISO 13849?1
- Performance Level (PL) d to EN ISO 13849?1
- Functional safety in accordance with IEC 61508: SIL 3 is possible in conjunction with options S01+Y11 or S02+Y11.
Communication
- Communication via conventional terminal strip with freely programmable digital and analog inputs/outputs with
- parameterizable limit value signals
- parameterizable timers
- parameterizable attenuators
- parameterizable converter behavior when inputs/outputs respond
- parameterizable logic elements
- Communication and parameterization by means of
- PC using IMS (Inverter Management Software) via USB interface
- External operator panel via RS485 link
- Bus systems such as Ethernet
(PROFIBUS with Ethernet-to-PROFIBUS converter board), PROFIBUS DP, CANopen, Modbus RTU or Modbus TCP
Drive behavior
- Closed-loop control of synchronous and induction motors
- Two control modes for induction motors:
- Space vector control for standard applications (without feedback)
- Field-oriented closed-loop control for dynamic requirements
- Optimum braking without any supplementary equipment by means of oversaturation control system. With approximately 10 % braking torque at high speed range and up to 50 % at low to medium speed range.
General
- Automatic slip compensation
- Stall protection provided by current limitation control
- Flying restart function for connection to rotating motor
- Automatic adjustment of the overload times
- Parameterizable DC braking for precise deceleration down to zero speed
- Torque control
- Automatic restart (Auto Restart)
- Voltage and current control systems
(AC as well as DC with variable frequency)
- Mains supply backup is possible
- Integrated process controller for basic, higher-level closed-loop control tasks
- Optionally available integrated braking chopper for increased braking torque
- Operation of groups of units with interconnected DC links is possible
|
|