2SP120
|
2SP125
|
|
Standard functions
|
|
Enclosure
|
Cartridge with flange mounting
|
Cartridge with flange mounting
|
|
Working position
|
Horizontal/vertical
|
Horizontal/vertical
|
|
Tool holder
|
HSK A63
|
SK 40 for tools with asymmetrical sliding blocks
|
|
Tool clamping device
|
- Release using pneumatic cylinder, 6 bar
- Clamping using cup-spring assembly
|
- Release using pneumatic cylinder, 6 bar
- Clamping using cup-spring assembly
|
|
Speed, max.
|
15000 rpm
|
10000 rpm
|
|
Bearing lubrication
|
Grease, permanent lubrication
|
Grease, permanent lubrication
|
|
Seal, bearing front
|
Sealing air 1 ... 1.5 m3/h, filter grade 8 µm
|
Sealing air 1 ... 1.5 m3/h, filter grade 8 µm
|
|
Tool taper cleaning
|
Compressed air through draw-bar 5 ... 6 bar
|
Compressed air through draw-bar 5 ... 6 bar
|
|
Insulation of the stator winding in accordance with EN 60034-1 (IEC 600034-1)
|
Temperature class 155 (F) for a coolant inlet temperature of 25 °C (77 °F)
|
Temperature class 155 (F) for a coolant inlet temperature of 25 °C (77 °F)
|
|
Degree of protection in accordance with IEC 60034-5
|
|
|
|
|
IP64
|
IP64
|
- Behind the spindle flange
|
IP53
|
IP53
|
|
Recommended coolant inlet temperature, approx.
|
25 °C (77 °F) (depending on the ambient temperature)
|
25 °C (77 °F) (depending on the ambient temperature)
|
|
Measuring system
|
Hollow-shaft measuring system, incremental, sin/cos 1 Vpp 256 S/R with zero mark
|
Hollow-shaft measuring system, incremental, sin/cos 1 Vpp 256 S/R with zero mark
|
|
Standard protection - temperature monitoring
|
- Motor thermal sensor KTY84-130
- PTC for full thermal protection
- NTC PT3-51F
- NTC K227
|
- Motor thermal sensor KTY84-130
|
|
Clamping status monitoring
|
|
|
|
|
- Tool clamped
- Draw-bar in release position
- Clamped without tool
|
–
|
|
|
- Position of release piston
|
- Tool clamped
- Draw-bar in release position
- Clamped without tool
|
|
Cooling with water
|
- Max. 5 bar, 10 l/min
- Max. 25 % corrosion protection agent
Clariant Antifrogen N or Tyfocor
- Filter grade 100 ?m
|
- Max. 5 bar, 10 l/min
- Max. 25 % corrosion protection agent
Clariant Antifrogen N or Tyfocor
- Filter grade 100 ?m
|
|
Connections for the media
|
|
|
|
|
2 ? hose plug-in connector, O 12 mm/10 mm (0.47 in/0.39 in)
|
2 ? G 1/2“ (O 9 mm) (0.35 in))
|
|
|
1 ? G 1/8“ radial/O 5 mm (0.20 in) axial
|
1 ? G 1/8“ (O 8 mm)
|
|
|
1 ? G 1/4“
|
1 ? G 1/4“
|
|
|
1 ? G 1/4“
|
1 ? M16 ? 1,5
|
|
|
1 ? G 1/8“
|
1 ? G 1/8“
|
|
Electrical connections
|
- Power through cable 1.5 m (4.92 ft)
- Sensors through signal plug
|
- Power through cable 1.5 m (4.92 ft)
- Sensors through signal plug
|
|
Options
|
|
Internal tool cooling
|
- 50 bar, up to 54 l/min
- Filter grade 50 ?m according to -/16/13 ISO 4406
- 1 ? G1/4“ coolant
- 1 ? G1/8“ leakage
|
- 50 bar, up to 54 l/min
- Filter grade 50 ?m according to -/16/13 ISO 4406
- 1 ? G1/4“ coolant
- 1 ? G1/8“ leakage
|
|
External tool cooling
|
- Ring with 6 adjustable nozzles
- 5 bar
- Filter grade 50 ?m in according to -/16/13 ISO 4406
|
–
|
|
Increased max. speed
|
18000 rpm
|
15000 rpm (with HSK A63)
|
|
Tool clamping device
|
- Release using hydraulic cylinder, 80 bar
- Clamping using cup-spring assembly
- 1 ? G 1/4“, release tool
- 1 ? G 1/4“, clamp tool
|
–
|
|
Tool interface
|
–
|
BT 40, CAT 40, HSK A63
|