? A CU310-2 Control Unit can perform the communication, open-loop and closed-loop control functions for one Power Module. The performance expansion is not required in this case. In addition to the firmware, the CompactFlash card also contains licensing codes which are required to enable firmware options (Safety Integrated Extended Functions in the current version). The Safety Integrated Extended Functions must be ordered via the order code F01 in addition to the Order No. The firmware option can also be enabled on-site, for example, if the Safety Integrated Extended Functions are to be enabled retrospectively. You will need the serial number of the Compact-Flash card and the Order No. of the firmware option to be enabled. With this information, you can purchase the associated license code from a license database and enable the firmware option. The license code is only valid for the CompactFlash card declared and cannot be transferred to other CompactFlash cards. |