DC link voltage 510 ... 720 V DC
|
Braking Module in chassis format
|
|
|
6SL3300-1AE31?3AA0
|
6SL3300-1AE32?5AA0
|
6SL3300-1AE32?5BA0
|
|
Power
|
|
|
|
|
|
|
kW
|
25
|
50
|
50
|
|
|
kW
|
125
|
250
|
250
|
|
|
kW
|
100
|
200
|
200
|
|
|
kW
|
50
|
100
|
100
|
|
Activation thresholds
(adjustable via DIP switch)
|
V
|
774 (factory setting) or 673
|
774 (factory setting) or 673
|
774 (factory setting) or 673
|
|
Cable length
to braking resistor, max.
|
m (ft)
|
100 (328)
|
100 (328)
|
100 (328)
|
|
Digital inputs
In accordance with IEC 61131-2 Type 1
|
|
|
|
|
|
|
V
|
-3 … +30
|
-3 … +30
|
-3 … +30
|
- Low level (an open digital input is interpreted as "low")
|
V
|
-3 … +5
|
-3 … +5
|
-3 … +5
|
|
|
V
|
15 … 30
|
15 … 30
|
15 … 30
|
- Current consumption
at 24 V DC, typ.
|
mA
|
10
|
10
|
10
|
- Conductor cross-section, max.
|
mm2
|
1.5
|
1.5
|
1.5
|
|
Digital outputs
(sustained short-circuit proof)
|
|
|
|
|
|
|
V
|
DC 24
|
DC 24
|
DC 24
|
- Load current per digital output, max.
|
mA
|
500
|
500
|
500
|
- Conductor cross-section, max.
|
mm2
|
1.5
|
1.5
|
1.5
|
|
Connection
R1/R2
|
|
M8 screw
|
M8 screw
|
M8 screw
|
- Conductor cross-section, max.
|
mm2
|
35
|
50
|
50
|
|
Weight, approx.
|
kg (lb)
|
3.6 (8)
|
7.3 (16)
|
7.5 (17)
|
|
Approvals, according to
|
|
cURus
|
cURus
|
cURus
|
|
Suitable for installation in an air-cooled Motor Module, Power Module, or Line Module
|
Frame size
|
FX/FB
|
GX/GB 1)
|
HX/JX
|
1) Cable harness set 6SL3366-2NG00-0AA0 is required to connect the Braking Module to a Basic Line Module of frame size GB.
|
DC link voltage 675 ... 900 V DC
|
Braking Module in chassis format
|
|
|
6SL3300-1AF31?3AA0
|
6SL3300-1AF32?5AA0
|
6SL3300-1AF32?5BA0
|
|
Power
|
|
|
|
|
|
|
kW
|
25
|
50
|
50
|
|
|
kW
|
125
|
250
|
250
|
|
|
kW
|
100
|
200
|
200
|
|
|
kW
|
50
|
100
|
100
|
|
Activation thresholds
(adjustable via DIP switch)
|
V
|
967 (factory setting) or 841
|
967 (factory setting) or 841
|
967 (factory setting) or 841
|
|
Cable length
to braking resistor, max.
|
m (ft)
|
100 (328)
|
100 (328)
|
100 (328)
|
|
Digital inputs
In accordance with IEC 61131-2 Type 1
|
|
|
|
|
|
|
V
|
-3 … +30
|
-3 … +30
|
-3 … +30
|
- Low level (an open digital input is interpreted as "low")
|
V
|
-3 … +5
|
-3 … +5
|
-3 … +5
|
|
|
V
|
15 … 30
|
15 … 30
|
15 … 30
|
- Current consumption at 24 V DC, typ.
|
mA
|
10
|
10
|
10
|
- Conductor cross-section, max.
|
mm2
|
1.5
|
1.5
|
1.5
|
|
Digital outputs
(sustained short-circuit proof)
|
|
|
|
|
|
|
V
|
DC 24
|
DC 24
|
DC 24
|
- Load current per digital output, max.
|
mA
|
500
|
500
|
500
|
- Conductor cross-section, max.
|
mm2
|
1.5
|
1.5
|
1.5
|
|
Connection R1/R2
|
|
M8 screw
|
M8 screw
|
M8 screw
|
- Conductor cross-section, max.
|
mm2
|
35
|
50
|
50
|
|
Weight, approx.
|
kg (lb)
|
3.6 (8)
|
7.3 (16)
|
7.5 (17)
|
|
Approvals, according to
|
|
cURus
|
cURus
|
cURus
|
|
Suitable for installation in an air-cooled Motor Module, or Line Module
|
Frame size
|
FX/FB
|
GX/GB 1)
|
HX/JX
|
1) Cable harness set 6SL3366-2NG00-0AA0 is required to connect the Braking Module to a Basic Line Module of frame size GB.
|
DC link voltage 890 ... 1035 V DC
|
Braking Module in chassis format
|
|
|
6SL3300-1AH31?3AA0
|
6SL3300-1AH32?5AA0
|
6SL3300-1AH32?5BA0
|
|
Power
|
|
|
|
|
|
|
kW
|
25
|
50
|
50
|
|
|
kW
|
125
|
250
|
250
|
|
|
kW
|
100
|
200
|
200
|
|
|
kW
|
50
|
100
|
100
|
|
Activation thresholds
(adjustable via DIP switch)
|
V
|
1153 (factory setting) or 1070
|
1153 (factory setting) or 1070
|
1153 (factory setting) or 1070
|
|
Cable length
to braking resistor, max.
|
m (ft)
|
100 (328)
|
100 (328)
|
100 (328)
|
|
Digital inputs
In accordance with IEC 61131-2 Type 1
|
|
|
|
|
|
|
V
|
-3 … +30
|
-3 … +30
|
-3 … +30
|
- Low level (an open digital input is interpreted as "low")
|
V
|
-3 … +5
|
-3 … +5
|
-3 … +5
|
|
|
V
|
15 … 30
|
15 … 30
|
15 … 30
|
- Current consumption at 24 V DC, typ.
|
mA
|
10
|
10
|
10
|
- Conductor cross-section, max.
|
mm2
|
1.5
|
1.5
|
1.5
|
|
Digital outputs
(sustained short-circuit proof)
|
|
|
|
|
|
|
V
|
DC 24
|
DC 24
|
DC 24
|
- Load current per digital output, max.
|
mA
|
500
|
500
|
500
|
- Conductor cross-section, max.
|
mm2
|
1.5
|
1.5
|
1.5
|
|
Connection
R1/R2
|
|
M8 screw
|
M8 screw
|
M8 screw
|
- Conductor cross-section, max.
|
mm2
|
35
|
50
|
50
|
|
Weight, approx.
|
kg (lb)
|
3.6 (8)
|
7.3 (16)
|
7.5 (17)
|
|
Approvals, according to
|
|
–
|
–
|
–
|
|
Suitable for installation in an air-cooled Motor Module, or Line Module
|
Frame size
|
FX/FB
|
GX/GB 1)
|
HX/JX
|
1) Cable harness set 6SL3366-2NG00-0AA0 is required to connect the Braking Module to a Basic Line Module of frame size GB.
|
|