Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Order No. |
6XV1 830-0EH10 |
6XV1 831-2A |
6XV1 830-0JH10 |
6XV1 830-0GH10 |
Product type designation |
PROFIBUS FC Standard Cable GP |
PROFIBUS FC Standard Cable IS GP |
PROFIBUS FC Robust Cable |
PROFIBUS FC Food Cable |
Product description |
Standard bus cable (2-core), sold by the meter, in bulk |
Standard bus cable for fast assembly, sold by the meter, in bulk |
Special bus cable (2-core), sold by the meter, in bulk |
Bus cable (2-core), sold by the meter, in bulk |
Suitability for use |
Standard cable of special design for fast assembly with fixed installation |
Use for intrinsically-safe distributed I/O systems, for fixed installation |
Use in chemically and mechanically stressed environments |
Use in the F & B industry |
Cable designation |
02YSY (ST) CY 1x2x0.64/2.55-150 VI KF 40 FR |
02YSY (ST) CY 1x2x0.64/2.55 BL KF40 FR |
02YSY (ST) C11Y 1x2x0.64/2.55-150 VI KF 40 FR |
02YSY (ST) C2Y 1x2x0.64/2.55-150 KF 40 |
Cable length |
- |
- |
- |
- |
Electrical specifications |
||||
Attenuation factor per length |
||||
|
2.5 dB/km |
2.5 dB/km |
2.5 dB/km |
2.5 dB/km |
|
4 dB/km |
4 dB/km |
4 dB/km |
4 dB/km |
|
22 dB/km |
22 dB/km |
22 dB/km |
22 dB/km |
|
42 dB/km |
42 dB/km |
42 dB/km |
42 dB/km |
Characteristic impedance |
||||
|
150 |
150 |
150 |
150 |
|
270 |
270 |
270 |
270 |
|
185 |
185 |
185 |
185 |
|
150 |
150 |
150 |
150 |
Relative symmetrical tolerance |
||||
|
10 % |
10 % |
10 % |
10 % |
|
10 % |
10 % |
10 % |
10 % |
|
10 % |
10 % |
10 % |
10 % |
Max. loop resistance per length |
110 /km |
110 /km |
110 /km |
110 /km |
Max. shield resistance per length |
9.5 /km |
9.5 /km |
9.5 /km |
9.5 /km |
Capacitance per length at 1 kHz |
28.5 pF/m |
28.5 pF/m |
28.5 pF/m |
28.5 pF/m |
Operating voltage, rms value |
100 V |
100 V |
100 V |
100 V |
Mechanical data |
||||
Number of electrical cores |
2 |
2 |
2 |
2 |
Design of shield |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Design of electrical connection FastConnect |
Yes |
Yes |
Yes |
Yes |
Outer diameter |
||||
|
0.65 mm |
0.64 mm |
0.65 mm |
0.65 mm |
|
2.55 mm |
2.55 mm |
2.55 mm |
2.55 mm |
|
5.4 mm |
5.4 mm |
5.4 mm |
5.4 mm |
|
8 mm |
8 mm |
8 mm |
8 mm |
Symmetrical tolerance of outer diameter of cable sheath |
0.4 mm |
0.4 mm |
0.4 mm |
0.4 mm |
Outer diameter of cable sheath - Note |
- |
- |
- |
- |
Material |
||||
|
PE |
PE |
PE |
PE |
|
PVC |
PVC |
PVC |
PVC |
|
PVC |
PVC |
PUR |
PE |
|
- |
- |
- |
Outer shield made of PE particularly suitable for the food sector |
Color |
||||
|
Red / green |
Red / green |
Red / green |
Red / green |
|
Violet |
Blue |
Violet |
Black |
Bending radius |
||||
|
150 mm |
75 mm |
150 mm |
30 mm |
|
300 mm |
150 mm |
300 mm |
60 mm |
|
- |
- |
- |
- |
Number of bending cycles |
- |
- |
- |
- |
|
- |
- |
- |
- |
Number of torsion cycles with torsion by ± 180° on 1 m cable length |
- |
- |
- |
- |
Maximum tensile load |
100 N |
100 N |
100 N |
100 N |
Weight per length |
0.08 kg/m |
80 kg/km |
71 kg/km |
67 kg/km |
Permitted ambient conditions |
||||
Ambient temperature |
||||
|
-40 … +75 °C |
-40 … +75 °C |
-40 … +60 °C |
-40 … +60 °C |
|
-40 … +75 °C |
-40 … +75 °C |
-40 … +60 °C |
-40 … +60 °C |
|
-40 … +75 °C |
-40 … +75 °C |
-40 … +60 °C |
-40 … +60 °C |
|
-40 … +75 °C |
-40 … +75 °C |
-40 … +60 °C |
-40 … +60 °C |
Ambient conditions for operation |
- |
- |
- |
- |
IP degree of protection |
- |
- |
- |
- |
Behavior in fire |
Flame-retardant in accordance with IEC 60332-3-24 (Category C) and UL 1685 (CSA FT 4) |
Flame-retardant in accordance with IEC 60332-3-24 (Category C) |
Flame-retardant in accordance with IEC 60332-1 |
Flammable |
Chemical resistance |
||||
|
Limited resistance |
Limited resistance |
Resistant |
Limited resistance |
|
Limited resistance |
Limited resistance |
Resistant |
Limited resistance |
|
- |
- |
- |
- |
Radiological resistance to UV radiation |
Resistant |
Resistant |
Resistant |
Resistant |
Product properties, functions, components General |
||||
Product property |
||||
|
No |
No |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
Cable length |
||||
|
100 m |
100 m |
100 m |
100 m |
|
200 m |
200 m |
200 m |
200 m |
Standards, specifications, approvals |
||||
UL listing at 300 V rating |
Yes: CMG / CL3 / Sun Res |
Yes: CMG / CL3 / Sun Res |
Yes: CMX |
No |
UL-Style at 600 V rating |
Yes |
Yes |
No |
No |
Certificate of suitability |
T |
- |
- |
- |
|
Yes |
Yes |
Yes |
Yes |
Marine classification corporation |
||||
|
No |
No |
No |
No |
|
No |
No |
No |
No |
Order No. |
6XV1 830-3FH10 |
6XV1 831-2K |
6XV1 830-3EH10 |
6XV1 831-2L |
Product type designation |
PROFIBUS FC Ground Cable |
PROFIBUS FC Flexible Cable |
PROFIBUS FC Trailing Cable |
PROFIBUS FC Trailing Cable |
Product description |
Special bus cable (2-core) with additional outer shield, sold by the meter, in bulk |
Flexible bus cable (4-core), sold by the meter, in bulk |
Highly flexible bus cable (2-core), sold by the meter, in bulk |
Highly flexible bus cable (2-core), sold by the meter, in bulk |
Suitability for use |
For use as buried cable |
For occasionally moved machine components |
Continuous movement in a trailing cable |
Continuous movement in a trailing cable |
Cable designation |
02YSY (ST) CY2Y 1x2x0.64/2.55-150 SW KF 40 |
02YH (ST) C11Y 1x2x0.65/2.56-150 LI KF40 FRNC FC VI |
02YY (ST) C11Y 1x2x0.65/2.56-150 LI KF 40 FR petrol |
02YY (ST) C11Y 1x2x0.65/2.56-150 LI KF 40 FR VT FC |
Cable length |
- |
- |
- |
- |
Electrical specifications |
||||
Attenuation factor per length |
||||
|
2.5 dB/km |
3 dB/km |
3 dB/km |
3 dB/km |
|
4 dB/km |
4 dB/km |
4 dB/km |
4 dB/km |
|
22 dB/km |
25 dB/km |
25 dB/km |
25 dB/km |
|
42 dB/km |
49 dB/km |
49 dB/km |
49 dB/km |
Characteristic impedance |
||||
|
150 |
150 |
150 |
150 |
|
270 |
270 |
270 |
270 |
|
185 |
185 |
185 |
185 |
|
150 |
150 |
150 |
150 |
Relative symmetrical tolerance |
||||
|
10 % |
10 % |
10 % |
10 % |
|
10 % |
10 % |
10 % |
10 % |
|
10 % |
10 % |
10 % |
10 % |
Max. loop resistance per length |
110 /km |
133 /km |
133 /km |
133 /km |
Max. shield resistance per length |
9.5 /km |
14 /km |
14 /km |
14 /km |
Capacitance per length at 1 kHz |
28.5 pF/m |
28 pF/m |
28 pF/m |
28 pF/m |
Operating voltage, rms value |
100 V |
100 V |
100 V |
100 V |
Mechanical data |
||||
Number of electrical cores |
2 |
2 |
2 |
2 |
Design of shield |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Design of electrical connection FastConnect |
Yes |
Yes |
Yes |
Yes |
Outer diameter |
||||
|
0.65 mm |
0.67 mm |
0.67 mm |
0.67 mm |
|
2.55 mm |
2.56 mm |
2.56 mm |
2.56 mm |
|
5.4 mm |
5.4 mm |
5.4 mm |
5.4 mm |
|
10.8 mm |
8 mm |
8 mm |
8 mm |
Symmetrical tolerance of outer diameter of cable sheath |
0.5 mm |
0.4 mm |
0.4 mm |
0.4 mm |
Outer diameter of cable sheath - Note |
The cable (diameter 8.0 mm +-0.4 mm) has an additional black outer shield (diameter 10.8 mm +-0.5 mm) as protection against destruction when used as a buried cable. Because of the outer diameter > 8 mm: bus connectors can only be connected following removal of the outer shield. |
- |
- |
- |
Material |
||||
|
PE |
PE |
PE |
PE |
|
PVC |
FRNC |
PVC |
PVC |
|
PE / PVC |
PUR |
PUR |
PUR |
|
PVC (cable shield), PE (additional outer shield) |
- |
- |
- |
Color |
||||
|
Red / green |
Red / green |
Red / green |
Red / green |
|
Black |
Violet |
Petrol |
Violet |
Bending radius |
||||
|
41 mm |
40 mm |
40 mm |
40 mm |
|
81 mm |
120 mm |
120 mm |
120 mm |
|
- |
- |
- |
- |
Number of bending cycles |
- |
- |
3 000 000 |
3 000 000 |
|
- |
- |
Suitable as trailing cable for 3 million bending cycles with a bending radius of 120 mm (15x D), and an acceleration of 4 m/s |
Suitable as trailing cable for 3 million bending cycles with a bending radius of 120 mm (15x D), and an acceleration of 4 m/s |
Number of torsion cycles with torsion by ± 180° on 1 m cable length |
- |
- |
- |
- |
Maximum tensile load |
100 N |
100 N |
100 N |
100 N |
Weight per length |
117 kg/km |
70 kg/km |
77 kg/km |
77 kg/km |
Permitted ambient conditions |
||||
Ambient temperature |
||||
|
-40 … +60 °C |
-20 … +60 °C |
-40 … +60 °C |
-40 … +60 °C |
|
-40 … +60 °C |
-40 … +60 °C |
-40 … +60 °C |
-40 … +60 °C |
|
-40 … +60 °C |
-40 … +60 °C |
-40 … +60 °C |
-40 … +60 °C |
|
-40 … +60 °C |
-40 … +60 °C |
-40 … +60 °C |
-40 … +60 °C |
Ambient conditions for operation |
- |
Restricted segment lengths (see Manual for PROFIBUS networks) |
Restricted segment lengths (see Manual for PROFIBUS networks) |
Restricted segment lengths (see Manual for PROFIBUS networks) |
IP degree of protection |
- |
- |
- |
- |
Behavior in fire |
Flammable |
Flame-retardant in accordance with IEC 60332-1-2 |
Flame-retardant in accordance with IEC 60332-1-2 |
Flame-retardant in accordance with IEC 60332-1-2 |
Chemical resistance |
||||
|
Limited resistance |
Resistant |
Resistant |
Resistant |
|
Limited resistance |
Resistant |
Resistant |
Resistant |
|
- |
- |
- |
- |
Radiological resistance to UV radiation |
Resistant |
Resistant |
Resistant |
Resistant |
Product properties, functions, components General |
||||
Product property |
||||
|
No |
Yes |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
Cable length |
||||
|
200 m |
200 m |
200 m |
200 m |
|
100 m |
100 m |
100 m |
100 m |
Standards, specifications, approvals |
||||
UL listing at 300 V rating |
No |
Yes: CMX |
Yes: CMX |
Yes: CMX |
UL-Style at 600 V rating |
No |
No |
No |
No |
Certificate of suitability |
- |
- |
- |
- |
|
Yes |
Yes |
Yes |
Yes |
Marine classification association |
||||
|
No |
No |
No |
No |
|
No |
No |
No |
No |
Order No. |
6XV1 830-0LH10 |
6XV1 830-3GH10 |
6XV1 830-0PH10 |
6XV1 830-0MH10 |
Product type designation |
PROFIBUS FC FRNC Cable GP |
PROFIBUS Festoon Cable GP |
PROFIBUS Torsion Cable |
SIENOPYR FR Marine Cable |
Product description |
Highly flamed retardant, halogen-free bus cable (2-core), sold by the meter, in bulk |
Flexible bus cable (2-core), sold by the meter, in bulk |
Highly flexible bus cable (2-core), sold by the meter, in bulk |
Bus cable (2-core), sold by the meter, in bulk |
Suitability for use |
Halogen-free cable, suitable for indoor use |
Special for use on festoons |
Use in moved machine components |
Cable for installation on ships and offshore units |
Cable designation |
02YSH (ST) CH 1x2x0.64/2.55-150 VI KF 25 FRNC FC |
02YS (ST) CY 1x2x0.65/2.56 LI petrol FR |
02Y (ST) C 11Y 1x2x0.8/2.56-150 LI FR VI |
M-02Y (ST) CH X 1 x 2 x 0.35 100 V |
Cable length |
- |
- |
- |
- |
Electrical specifications |
||||
Attenuation factor per length |
||||
|
2.5 dB/km |
3 dB/km |
2.5 dB/km |
3 dB/km |
|
4 dB/km |
4 dB/km |
3 dB/km |
5 dB/km |
|
22 dB/km |
25 dB/km |
25 dB/km |
22 dB/km |
|
42 dB/km |
49 dB/km |
49 dB/km |
45 dB/km |
Characteristic impedance |
||||
|
150 |
150 |
150 |
150 |
|
270 |
270 |
270 |
250 |
|
185 |
185 |
185 |
185 |
|
150 |
150 |
150 |
150 |
Relative symmetrical tolerance |
||||
|
10 % |
10 % |
10 % |
10 % |
|
10 % |
10 % |
10 % |
10 % |
|
10 % |
10 % |
10 % |
10 % |
Max. loop resistance per length |
110 /km |
133 /km |
98 /km |
110 /km |
Max. shield resistance per length |
9.5 /km |
19 /km |
14 /km |
- |
Capacitance per length at 1 kHz |
28.5 pF/m |
28 pF/m |
29 pF/m |
- |
Operating voltage, rms value |
100 V |
100 V |
100 V |
100 V |
Mechanical data |
||||
Number of electrical cores |
2 |
2 |
2 |
2 |
Design of shield |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Design of FastConnect electrical connection |
Yes |
No |
No |
No |
Outer diameter |
||||
|
0.65 mm |
0.67 mm |
0.8 mm |
0.67 mm |
|
2.55 mm |
2.56 mm |
2.56 mm |
- |
|
5.4 mm |
5.8 mm |
6 mm |
8 mm |
|
8 mm |
8 mm |
8 mm |
10.3 mm |
Symmetrical tolerance of outer diameter of cable sheath |
0.4 mm |
0.3 mm |
0.4 mm |
0.5 mm |
Outer diameter of cable sheath - Note |
- |
- |
- |
Outer diameter > 8 mm: bus connectors can only be connected following removal of the outer shield |
Material |
||||
|
PE |
PE |
PE |
PE |
|
FRNC |
- |
- |
Halogen-free polymer (HM4) |
|
FRNC |
PVC |
PUR |
Halogen-free cross-linked polymer |
|
- |
- |
- |
- |
Color |
||||
|
Red / green |
Red / green |
Red / green |
Red / green |
|
Violet |
Petrol |
Violet |
Black |
Bending radius |
||||
|
60 mm |
30 mm |
30 mm |
103 mm |
|
80 mm |
70 mm |
60 mm |
206 mm |
|
- |
- |
- |
- |
Number of bending cycles |
- |
- |
- |
- |
|
- |
- |
Not suitable for festoon mounting |
- |
Number of torsion cycles with torsion by ± 180° on 1 m cable length |
- |
- |
5 000 000 |
- |
Maximum tensile load |
100 N |
80 N |
100 N |
100 N |
Weight per length |
72 kg/km |
64 kg/km |
65 kg/km |
109 kg/km |
Permissible ambient conditions |
||||
Ambient temperature |
||||
|
-25 … +80 °C |
-40 … +80 °C |
-25 … +75 °C |
-40 … +80 °C |
|
-25 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
|
-25 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
|
-25 … +80 °C |
-40 … +80 °C |
-25 … +75 °C |
-10 … +80 °C |
Ambient conditions for operation |
- |
- |
- |
At ambient temperatures below -10 °C the cables must not be exposed to any more vibrations than those normally encountered in marine applications. |
IP degree of protection |
- |
- |
- |
- |
Behavior in fire |
Flame-retardant in accordance with IEC 60332-3-24 (Category C), IEC 60332-3-22 (Category A) |
Flame-retardant in accordance with IEC 60332-3-24 (Category C) |
Flame-retardant in accordance with IEC 60332-1-2 |
Flame-retardant in accordance with IEC 60332-3-24 |
Chemical resistance |
||||
|
Limited resistance |
Limited resistance |
Resistant |
Resistant |
|
Limited resistance |
Limited resistance |
Resistant |
Resistant |
|
- |
- |
- |
Limited resistance |
Radiological resistance to UV radiation |
Resistant |
Resistant |
Resistant |
Resistant |
Product properties, functions, components General |
||||
Product property |
||||
|
Yes |
No |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Cable length |
||||
|
200 m |
200 m |
200 m |
200 m |
|
100 m |
100 m |
60 m |
100 m |
Standards, specifications, approvals |
||||
UL listing at 300 V rating |
Yes: CM / CL3 / Sun Res |
Yes: CMG / PLCT / Sun Res / Oil Res |
Yes: CMX |
No |
UL-Style at 600 V rating |
Yes |
Yes |
No |
No |
Certificate of suitability |
- |
- |
- |
- |
|
Yes |
- |
Yes |
- |
Marine classification association |
||||
|
No |
No |
No |
Yes |
|
No |
No |
No |
Yes |
Order No. |
6XV1 860-2R |
6XV1 860-2S |
Product type designation |
PROFIBUS Hybrid Standard Cable GP |
PROFIBUS Hybrid Robust Cable |
Product description |
Hybrid cable (data and power cores), sold by the meter, in bulk |
Hybrid cable (data and power cores), sold by the meter, in bulk |
Suitability for use |
Hybrid cable suitable as trailing cable, for data and power supply to ET 200pro |
Rugged cable for data and power supply to ET 200pro in mechanically stressed environments. Cable resistant to spatter in accordance with HD22.2 S3 / 5 |
Cable designation |
02Y(ST)C 1x2x0.65/2.56-150LI LIY-Z Y 2x1x1.5 VI |
02Y(ST)C 1x2x0.65/2.56-150LI LIH-Z 11Y 2x1x1.5 VI FRNC |
Cable length |
- |
- |
Electrical specifications |
||
Attenuation factor per length |
||
|
||
|
0.004 dB/m |
0.004 dB/m |
|
0.025 dB/m |
0.025 dB/m |
|
0.049 dB/m |
0.049 dB/m |
Characteristic impedance |
||
|
150 |
150 |
|
270 |
270 |
|
185 |
185 |
|
150 |
150 |
Relative symmetrical tolerance |
||
|
10 % |
10 % |
|
10 % |
10 % |
|
10 % |
10 % |
Max. loop resistance per length |
138 /km |
138 /km |
Max. shield resistance per length |
10 /km |
10 /km |
Capacitance per length at 1 kHz |
30 pF/m |
30 pF/m |
Inductance per length |
- |
- |
Operating voltage, rms value |
300 V |
300 V |
Conductor cross-section of power core |
1.5 mm |
1.5 mm |
Continuous current of power cores |
7.5 A |
7.5 A |
Mechanical data |
||
Design of shield |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Number of electrical cores |
2 |
2 |
Design of electrical connection FastConnect |
No |
No |
Outer diameter |
||
|
2.56 mm |
2.56 mm |
|
- |
- |
|
11 mm |
11 mm |
Symmetrical tolerance of outer diameter of cable sheath |
0.5 mm |
0.5 mm |
Outer diameter of cable sheath - Note |
- |
- |
Material |
||
|
PE |
PE |
|
- |
- |
|
PVC |
PUR |
|
- |
- |
Color |
||
|
Red / green |
Red / green |
|
Black |
Black |
|
Violet |
Violet |
Bending radius |
||
|
44 mm |
44 mm |
|
125 mm |
125 mm |
Number of bending cycles |
- |
- |
|
- |
- |
Number of torsion cycles with torsion by ± 180° on 1 m cable length |
- |
- |
Maximum tensile load |
450 N |
450 N |
Weight per length |
140 kg/km |
135 kg/km |
Permissible ambient conditions |
||
Ambient temperature |
||
|
-40 … +75 °C |
-40 … +75 °C |
|
-40 … +75 °C |
-40 … +75 °C |
|
-40 … +75 °C |
-40 … +75 °C |
|
-40 … +75 °C |
-40 … +75 °C |
Ambient conditions for operation |
- |
- |
IP degree of protection |
- |
- |
Behavior in fire |
Flame-retardant in accordance with IEC 60332-1-2 |
Flame-retardant in accordance with IEC 60332-1-2 |
Chemical resistance |
||
|
Limited resistance |
Resistant |
|
Limited resistance |
Resistant |
|
- |
- |
Radiological resistance to UV radiation |
Not resistant |
Resistant |
Product properties, functions, components General |
||
Product property |
||
|
No |
Yes |
|
Yes |
Yes |
Standards, specifications, approvals |
||
UL listing at 300 V rating |
Yes: CMG |
Yes: CMX |
UL-Style at 600 V rating |
No |
No |
Certificate of suitability |
- |
- |
|
Yes |
Yes |