Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2012
архивный
(4872) 700-366
skenergo@mail.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
PROFIBUS bus cables

Order No.

6XV1 830-0EH10

6XV1 831-2A

6XV1 830-0JH10

6XV1 830-0GH10

Product type designation

PROFIBUS FC Standard Cable GP

PROFIBUS FC Standard Cable IS GP

PROFIBUS FC Robust Cable

PROFIBUS FC Food Cable

Product description

Standard bus cable (2-core), sold by the meter, in bulk

Standard bus cable for fast assembly, sold by the meter, in bulk

Special bus cable (2-core), sold by the meter, in bulk

Bus cable (2-core), sold by the meter, in bulk

Suitability for use

Standard cable of special design for fast assembly with fixed installation

Use for intrinsically-safe distributed I/O systems, for fixed installation

Use in chemically and mechanically stressed environments

Use in the F & B industry

Cable designation

02YSY (ST) CY 1x2x0.64/2.55-150 VI KF 40 FR

02YSY (ST) CY 1x2x0.64/2.55 BL KF40 FR

02YSY (ST) C11Y 1x2x0.64/2.55-150 VI KF 40 FR

02YSY (ST) C2Y 1x2x0.64/2.55-150 KF 40

Cable length

-

-

-

-

Electrical specifications

Attenuation factor per length

  • Max. at 9.6 kHz

2.5 dB/km

2.5 dB/km

2.5 dB/km

2.5 dB/km

  • Max. at 38.4 kHz

4 dB/km

4 dB/km

4 dB/km

4 dB/km

  • Max. at 4 MHz

22 dB/km

22 dB/km

22 dB/km

22 dB/km

  • Max. at 16 MHz

42 dB/km

42 dB/km

42 dB/km

42 dB/km

Characteristic impedance

  • Rated value

150 

150 

150 

150 

  • at 9.6 kHz

270 

270 

270 

270 

  • at 38.4 kHz

185 

185 

185 

185 

  • at 3 MHz ... 20 MHz

150 

150 

150 

150 

Relative symmetrical tolerance

  • of characteristic impedance at 9.6 kHz

10 %

10 %

10 %

10 %

  • of characteristic impedance at 38.4 kHz

10 %

10 %

10 %

10 %

  • of characteristic impedance at 3 MHz to 20 MHz

10 %

10 %

10 %

10 %

Max. loop resistance per length

110  /km

110  /km

110  /km

110  /km

Max. shield resistance per length

9.5  /km

9.5  /km

9.5  /km

9.5  /km

Capacitance per length at 1 kHz

28.5 pF/m

28.5 pF/m

28.5 pF/m

28.5 pF/m

Operating voltage, rms value

100 V

100 V

100 V

100 V

Mechanical data

Number of electrical cores

2

2

2

2

Design of shield

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Design of electrical connection FastConnect

Yes

Yes

Yes

Yes

Outer diameter

  • of inner conductor

0.65 mm

0.64 mm

0.65 mm

0.65 mm

  • of core insulation

2.55 mm

2.55 mm

2.55 mm

2.55 mm

  • of inner sheath of cable

5.4 mm

5.4 mm

5.4 mm

5.4 mm

  • of cable sheath

8 mm

8 mm

8 mm

8 mm

Symmetrical tolerance of outer diameter of cable sheath

0.4 mm

0.4 mm

0.4 mm

0.4 mm

Outer diameter of cable sheath - Note

-

-

-

-

Material

  • of core insulation

PE

PE

PE

PE

  • of inner sheath of cable

PVC

PVC

PVC

PVC

  • of the cable sheath

PVC

PVC

PUR

PE

    • Note

-

-

-

Outer shield made of PE particularly suitable for the food sector

Color

  • of core insulation of data cores

Red / green

Red / green

Red / green

Red / green

  • of the cable sheath

Violet

Blue

Violet

Black

Bending radius

  • with single bending

150 mm

75 mm

150 mm

30 mm

  • With repeated bending

300 mm

150 mm

300 mm

60 mm

  • With continuous bending

-

-

-

-

Number of bending cycles

-

-

-

-

  • Note

-

-

-

-

Number of torsion cycles with torsion by ± 180° on 1 m cable length

-

-

-

-

Maximum tensile load

100 N

100 N

100 N

100 N

Weight per length

0.08 kg/m

80 kg/km

71 kg/km

67 kg/km

Permitted ambient conditions

Ambient temperature

  • During operation

-40 … +75 °C

-40 … +75 °C

-40 … +60 °C

-40 … +60 °C

  • During storage

-40 … +75 °C

-40 … +75 °C

-40 … +60 °C

-40 … +60 °C

  • During transport

-40 … +75 °C

-40 … +75 °C

-40 … +60 °C

-40 … +60 °C

  • During mounting

-40 … +75 °C

-40 … +75 °C

-40 … +60 °C

-40 … +60 °C

Ambient conditions for operation

-

-

-

-

IP degree of protection

-

-

-

-

Behavior in fire

Flame-retardant in accordance with IEC 60332-3-24 (Category C) and UL 1685 (CSA FT 4)

Flame-retardant in accordance with IEC 60332-3-24 (Category C)

Flame-retardant in accordance with IEC 60332-1

Flammable

Chemical resistance

  • against mineral oil

Limited resistance

Limited resistance

Resistant

Limited resistance

  • against grease

Limited resistance

Limited resistance

Resistant

Limited resistance

  • against water

-

-

-

-

Radiological resistance to UV radiation

Resistant

Resistant

Resistant

Resistant

Product properties, functions, components General

Product property

  • Halogen-free

No

No

No

No

  • Silicon-free

Yes

Yes

Yes

Yes

Cable length

  • at 12 Mbit/s maximum

100 m

100 m

100 m

100 m

  • at 1.5 Mbit/s maximum

200 m

200 m

200 m

200 m

Standards, specifications, approvals

UL listing at 300 V rating

Yes: CMG / CL3 / Sun Res

Yes: CMG / CL3 / Sun Res

Yes: CMX

No

UL-Style at 600 V rating

Yes

Yes

No

No

Certificate of suitability

T

-

-

-

  • RoHS compliance

Yes

Yes

Yes

Yes

Marine classification corporation

  • Germanischer Lloyd (GL)

No

No

No

No

  • Llyods Register of Shipping (LRS)

No

No

No

No


Order No.

6XV1 830-3FH10

6XV1 831-2K

6XV1 830-3EH10

6XV1 831-2L

Product type designation

PROFIBUS FC Ground Cable

PROFIBUS FC Flexible Cable

PROFIBUS FC Trailing Cable

PROFIBUS FC Trailing Cable

Product description

Special bus cable (2-core) with additional outer shield, sold by the meter, in bulk

Flexible bus cable (4-core), sold by the meter, in bulk

Highly flexible bus cable (2-core), sold by the meter, in bulk

Highly flexible bus cable (2-core), sold by the meter, in bulk

Suitability for use

For use as buried cable

For occasionally moved machine components

Continuous movement in a trailing cable

Continuous movement in a trailing cable

Cable designation

02YSY (ST) CY2Y 1x2x0.64/2.55-150 SW KF 40

02YH (ST) C11Y 1x2x0.65/2.56-150 LI KF40 FRNC FC VI

02YY (ST) C11Y 1x2x0.65/2.56-150 LI KF 40 FR petrol

02YY (ST) C11Y 1x2x0.65/2.56-150 LI KF 40 FR VT FC

Cable length

-

-

-

-

Electrical specifications

Attenuation factor per length

  • Max. at 9.6 kHz

2.5 dB/km

3 dB/km

3 dB/km

3 dB/km

  • Max. at 38.4 kHz

4 dB/km

4 dB/km

4 dB/km

4 dB/km

  • Max. at 4 MHz

22 dB/km

25 dB/km

25 dB/km

25 dB/km

  • Max. at 16 MHz

42 dB/km

49 dB/km

49 dB/km

49 dB/km

Characteristic impedance

  • Rated value

150 

150 

150 

150 

  • at 9.6 kHz

270 

270 

270 

270 

  • at 38.4 kHz

185 

185 

185 

185 

  • at 3 MHz ... 20 MHz

150 

150 

150 

150 

Relative symmetrical tolerance

  • of characteristic impedance at 9.6 kHz

10 %

10 %

10 %

10 %

  • of characteristic impedance at 38.4 kHz

10 %

10 %

10 %

10 %

  • of characteristic impedance at 3 MHz to 20 MHz

10 %

10 %

10 %

10 %

Max. loop resistance per length

110  /km

133  /km

133  /km

133  /km

Max. shield resistance per length

9.5  /km

14  /km

14  /km

14  /km

Capacitance per length at 1 kHz

28.5 pF/m

28 pF/m

28 pF/m

28 pF/m

Operating voltage, rms value

100 V

100 V

100 V

100 V

Mechanical data

Number of electrical cores

2

2

2

2

Design of shield

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Design of electrical connection FastConnect

Yes

Yes

Yes

Yes

Outer diameter

  • of inner conductor

0.65 mm

0.67 mm

0.67 mm

0.67 mm

  • of core insulation

2.55 mm

2.56 mm

2.56 mm

2.56 mm

  • of inner sheath of cable

5.4 mm

5.4 mm

5.4 mm

5.4 mm

  • of cable sheath

10.8 mm

8 mm

8 mm

8 mm

Symmetrical tolerance of outer diameter of cable sheath

0.5 mm

0.4 mm

0.4 mm

0.4 mm

Outer diameter of cable sheath - Note

The cable (diameter 8.0 mm +-0.4 mm) has an additional black outer shield (diameter 10.8 mm +-0.5 mm) as protection against destruction when used as a buried cable. Because of the outer diameter > 8 mm: bus connectors can only be connected following removal of the outer shield.

-

-

-

Material

  • of core insulation

PE

PE

PE

PE

  • of inner sheath of cable

PVC

FRNC

PVC

PVC

  • of cable sheath

PE / PVC

PUR

PUR

PUR

    • Note

PVC (cable shield), PE (additional outer shield)

-

-

-

Color

  • of core insulation of data cores

Red / green

Red / green

Red / green

Red / green

  • of cable sheath

Black

Violet

Petrol

Violet

Bending radius

  • with single bending

41 mm

40 mm

40 mm

40 mm

  • With repeated bending

81 mm

120 mm

120 mm

120 mm

  • With continuous bending

-

-

-

-

Number of bending cycles

-

-

3 000 000

3 000 000

  • Note

-

-

Suitable as trailing cable for 3 million bending cycles with a bending radius of 120 mm (15x D), and an acceleration of 4 m/s

Suitable as trailing cable for 3 million bending cycles with a bending radius of 120 mm (15x D), and an acceleration of 4 m/s

Number of torsion cycles with torsion by ± 180° on 1 m cable length

-

-

-

-

Maximum tensile load

100 N

100 N

100 N

100 N

Weight per length

117 kg/km

70 kg/km

77 kg/km

77 kg/km

Permitted ambient conditions

Ambient temperature

  • During operation

-40 … +60 °C

-20 … +60 °C

-40 … +60 °C

-40 … +60 °C

  • During storage

-40 … +60 °C

-40 … +60 °C

-40 … +60 °C

-40 … +60 °C

  • During transport

-40 … +60 °C

-40 … +60 °C

-40 … +60 °C

-40 … +60 °C

  • During mounting

-40 … +60 °C

-40 … +60 °C

-40 … +60 °C

-40 … +60 °C

Ambient conditions for operation

-

Restricted segment lengths (see Manual for PROFIBUS networks)

Restricted segment lengths (see Manual for PROFIBUS networks)

Restricted segment lengths (see Manual for PROFIBUS networks)

IP degree of protection

-

-

-

-

Behavior in fire

Flammable

Flame-retardant in accordance with IEC 60332-1-2

Flame-retardant in accordance with IEC 60332-1-2

Flame-retardant in accordance with IEC 60332-1-2

Chemical resistance

  • against mineral oil

Limited resistance

Resistant

Resistant

Resistant

  • against grease

Limited resistance

Resistant

Resistant

Resistant

  • against water

-

-

-

-

Radiological resistance to UV radiation

Resistant

Resistant

Resistant

Resistant

Product properties, functions, components General

Product property

  • Halogen-free

No

Yes

No

No

  • Silicon-free

Yes

Yes

Yes

Yes

Cable length

  • at 1.5 Mbit/s maximum

200 m

200 m

200 m

200 m

  • at 12 Mbit/s maximum

100 m

100 m

100 m

100 m

Standards, specifications, approvals

UL listing at 300 V rating

No

Yes: CMX

Yes: CMX

Yes: CMX

UL-Style at 600 V rating

No

No

No

No

Certificate of suitability

-

-

-

-

  • RoHS compliance

Yes

Yes

Yes

Yes

Marine classification association

  • Germanischer Lloyd (GL)

No

No

No

No

  • Lloyds Register of Shipping (LRS)

No

No

No

No


Order No.

6XV1 830-0LH10

6XV1 830-3GH10

6XV1 830-0PH10

6XV1 830-0MH10

Product type designation

PROFIBUS FC FRNC Cable GP

PROFIBUS Festoon Cable GP

PROFIBUS Torsion Cable

SIENOPYR FR Marine Cable

Product description

Highly flamed retardant, halogen-free bus cable (2-core), sold by the meter, in bulk

Flexible bus cable (2-core), sold by the meter, in bulk

Highly flexible bus cable (2-core), sold by the meter, in bulk

Bus cable (2-core), sold by the meter, in bulk

Suitability for use

Halogen-free cable, suitable for indoor use

Special for use on festoons

Use in moved machine components

Cable for installation on ships and offshore units

Cable designation

02YSH (ST) CH 1x2x0.64/2.55-150 VI KF 25 FRNC FC

02YS (ST) CY 1x2x0.65/2.56 LI petrol FR

02Y (ST) C 11Y 1x2x0.8/2.56-150 LI FR VI

M-02Y (ST) CH X 1 x 2 x 0.35 100 V

Cable length

-

-

-

-

Electrical specifications

Attenuation factor per length

  • At 9.6 kHz maximum

2.5 dB/km

3 dB/km

2.5 dB/km

3 dB/km

  • At 38.4 kHz maximum

4 dB/km

4 dB/km

3 dB/km

5 dB/km

  • At 4 MHz maximum

22 dB/km

25 dB/km

25 dB/km

22 dB/km

  • At 16 MHz maximum

42 dB/km

49 dB/km

49 dB/km

45 dB/km

Characteristic impedance

  • Rated value

150 

150 

150 

150 

  • At 9.6 kHz

270 

270 

270 

250 

  • At 38.4 kHz

185 

185 

185 

185 

  • at 3 MHz ... 20 MHz

150 

150 

150 

150 

Relative symmetrical tolerance

  • of characteristic impedance at 9.6 kHz

10 %

10 %

10 %

10 %

  • of characteristic impedance at 38.4 kHz

10 %

10 %

10 %

10 %

  • of characteristic impedance at 3 MHz to 20 MHz

10 %

10 %

10 %

10 %

Max. loop resistance per length

110  /km

133  /km

98  /km

110  /km

Max. shield resistance per length

9.5  /km

19  /km

14  /km

-

Capacitance per length at 1 kHz

28.5 pF/m

28 pF/m

29 pF/m

-

Operating voltage, rms value

100 V

100 V

100 V

100 V

Mechanical data

Number of electrical cores

2

2

2

2

Design of shield

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Design of FastConnect electrical connection

Yes

No

No

No

Outer diameter

  • of inner conductor

0.65 mm

0.67 mm

0.8 mm

0.67 mm

  • of core insulation

2.55 mm

2.56 mm

2.56 mm

-

  • of inner sheath of cable

5.4 mm

5.8 mm

6 mm

8 mm

  • of the cable sheath

8 mm

8 mm

8 mm

10.3 mm

Symmetrical tolerance of outer diameter of cable sheath

0.4 mm

0.3 mm

0.4 mm

0.5 mm

Outer diameter of cable sheath - Note

-

-

-

Outer diameter > 8 mm: bus connectors can only be connected following removal of the outer shield

Material

  • of core insulation

PE

PE

PE

PE

  • of inner sheath of cable

FRNC

-

-

Halogen-free polymer (HM4)

  • of the cable sheath

FRNC

PVC

PUR

Halogen-free cross-linked polymer

    • Note

-

-

-

-

Color

  • of core insulation of data cores

Red / green

Red / green

Red / green

Red / green

  • of the cable sheath

Violet

Petrol

Violet

Black

Bending radius

  • With single bending

60 mm

30 mm

30 mm

103 mm

  • With repeated bending

80 mm

70 mm

60 mm

206 mm

  • With continuous bending

-

-

-

-

Number of bending cycles

-

-

-

-

  • Note

-

-

Not suitable for festoon mounting

-

Number of torsion cycles with torsion by ± 180° on 1 m cable length

-

-

5 000 000

-

Maximum tensile load

100 N

80 N

100 N

100 N

Weight per length

72 kg/km

64 kg/km

65 kg/km

109 kg/km

Permissible ambient conditions

Ambient temperature

  • During operation

-25 … +80 °C

-40 … +80 °C

-25 … +75 °C

-40 … +80 °C

  • During storage

-25 … +80 °C

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

  • During transport

-25 … +80 °C

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

  • During mounting

-25 … +80 °C

-40 … +80 °C

-25 … +75 °C

-10 … +80 °C

Ambient conditions for operation

-

-

-

At ambient temperatures below -10 °C the cables must not be exposed to any more vibrations than those normally encountered in marine applications.

IP degree of protection

-

-

-

-

Behavior in fire

Flame-retardant in accordance with IEC 60332-3-24 (Category C), IEC 60332-3-22 (Category A)

Flame-retardant in accordance with IEC 60332-3-24 (Category C)

Flame-retardant in accordance with IEC 60332-1-2

Flame-retardant in accordance with IEC 60332-3-24

Chemical resistance

  • against mineral oil

Limited resistance

Limited resistance

Resistant

Resistant

  • against grease

Limited resistance

Limited resistance

Resistant

Resistant

  • against water

-

-

-

Limited resistance

Radiological resistance to UV radiation

Resistant

Resistant

Resistant

Resistant

Product properties, functions, components General

Product property

  • Halogen-free

Yes

No

Yes

Yes

  • Silicon-free

Yes

Yes

Yes

Yes

Cable length

  • at 1.5 Mbit/s maximum

200 m

200 m

200 m

200 m

  • at 12 Mbit/s maximum

100 m

100 m

60 m

100 m

Standards, specifications, approvals

UL listing at 300 V rating

Yes: CM / CL3 / Sun Res

Yes: CMG / PLCT / Sun Res / Oil Res

Yes: CMX

No

UL-Style at 600 V rating

Yes

Yes

No

No

Certificate of suitability

-

-

-

-

  • RoHS compliance

Yes

-

Yes

-

Marine classification association

  • Germanischer Lloyd (GL)

No

No

No

Yes

  • Lloyds Register of Shipping (LRS)

No

No

No

Yes


Order No.

6XV1 860-2R

6XV1 860-2S

Product type designation

PROFIBUS Hybrid Standard Cable GP

PROFIBUS Hybrid Robust Cable

Product description

Hybrid cable (data and power cores), sold by the meter, in bulk

Hybrid cable (data and power cores), sold by the meter, in bulk

Suitability for use

Hybrid cable suitable as trailing cable, for data and power supply to ET 200pro

Rugged cable for data and power supply to ET 200pro in mechanically stressed environments. Cable resistant to spatter in accordance with HD22.2 S3 / 5

Cable designation

02Y(ST)C 1x2x0.65/2.56-150LI LIY-Z Y 2x1x1.5 VI

02Y(ST)C 1x2x0.65/2.56-150LI LIH-Z 11Y 2x1x1.5 VI FRNC

Cable length

-

-

Electrical specifications

Attenuation factor per length

  • Max. at 9.6 MHz

  • Max. at 38.4 kHz

0.004 dB/m

0.004 dB/m

  • Max. at 4 MHz

0.025 dB/m

0.025 dB/m

  • Max. at 16 MHz

0.049 dB/m

0.049 dB/m

Characteristic impedance

  • Rated value

150 

150 

  • at 9.6 kHz

270 

270 

  • at 38.4 kHz

185 

185 

  • at 3 MHz ... 20 MHz

150 

150 

Relative symmetrical tolerance

  • of characteristic impedance at 9.6 kHz

10 %

10 %

  • of characteristic impedance at 38.4 kHz

10 %

10 %

  • of characteristic impedance at 3 MHz to 20 MHz

10 %

10 %

Max. loop resistance per length

138  /km

138  /km

Max. shield resistance per length

10  /km

10  /km

Capacitance per length at 1 kHz

30 pF/m

30 pF/m

Inductance per length

-

-

Operating voltage, rms value

300 V

300 V

Conductor cross-section of power core

1.5 mm

1.5 mm

Continuous current of power cores

7.5 A

7.5 A

Mechanical data

Design of shield

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Number of electrical cores

2

2

Design of electrical connection FastConnect

No

No

Outer diameter

  • of core insulation

2.56 mm

2.56 mm

  • of inner sheath of cable

-

-

  • of the cable sheath

11 mm

11 mm

Symmetrical tolerance of outer diameter of cable sheath

0.5 mm

0.5 mm

Outer diameter of cable sheath - Note

-

-

Material

  • of core insulation

PE

PE

  • of inner sheath of cable

-

-

  • of the cable sheath

PVC

PUR

    • Note

-

-

Color

  • of core insulation of data cores

Red / green

Red / green

  • of core insulation of power cores

Black

Black

  • of the cable sheath

Violet

Violet

Bending radius

  • Minimum permitted single bending radius

44 mm

44 mm

  • Minimum permitted repeated bending radius

125 mm

125 mm

Number of bending cycles

-

-

  • Note

-

-

Number of torsion cycles with torsion by ± 180° on 1 m cable length

-

-

Maximum tensile load

450 N

450 N

Weight per length

140 kg/km

135 kg/km

Permissible ambient conditions

Ambient temperature

  • During operation

-40 … +75 °C

-40 … +75 °C

  • During storage

-40 … +75 °C

-40 … +75 °C

  • During transport

-40 … +75 °C

-40 … +75 °C

  • During mounting

-40 … +75 °C

-40 … +75 °C

Ambient conditions for operation

-

-

IP degree of protection

-

-

Behavior in fire

Flame-retardant in accordance with IEC 60332-1-2

Flame-retardant in accordance with IEC 60332-1-2

Chemical resistance

  • against mineral oil

Limited resistance

Resistant

  • against grease

Limited resistance

Resistant

  • against water

-

-

Radiological resistance to UV radiation

Not resistant

Resistant

Product properties, functions, components General

Product property

  • Halogen-free

No

Yes

  • Silicon-free

Yes

Yes

Standards, specifications, approvals

UL listing at 300 V rating

Yes: CMG

Yes: CMX

UL-Style at 600 V rating

No

No

Certificate of suitability

-

-

  • RoHS compliance

Yes

Yes
























































Каталог оборудования
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET ECOFAST Введение Industrial Ethernet PROFINET PROFIBUS Введение Полевая шина и передача данных процессов Передача данных Communication overview Примеры конфигураций Топологии Сетевые компоненты для PROFIBUS Обзор сетевых компонент Критерии выбора типа сети Примеры соединений Электрические сети (RS485) Технология FastConnect для PROFIBUS Сетевые кабели Сетевые кабели ECOFAST Цепи питания Коннектор к шине RS 485 Присоединительный кабель 830-1 Присоединительный кабель 830-2 PROFIBUS кабели M12 и 7/8 Шинный терминал Активный сетевой терминатор RS 485 Повторитель RS 485 для PROFIBUS Диагностический повторитель для PROFIBUS-DP Power Rail Booster Тестовый прибор BT 200 ADI 4 (модуль аналогового интерфейса для 4 осей) Электрические сети (PROFIBUS-PA) Электрические сети FOUNDATION Fieldbus Оптические сети с OLM Оптические сети с ОВТ и встроенными интерфейсами Беспроводные соединения Системные интерфейсы Сетевые переходы Управление в промышленности Приборы коммутации и защиты для распределения энергии Система управления потреблением энергии Устройства с PROFIBUS-DP RFID системы - коммуникационные модули Датчики Инжиниринговые пакеты Технологические компоненты для PROFIBUS Решения партнеров AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366
Яндекс.Метрика