Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
HCS724I heater control |
|
Climatic ambient conditions |
|
Operating temperature |
|
|
0 ... 55 °C |
|
95 % |
|
10 K/h |
Storage temperature |
|
|
-40 ... +70 °C |
|
95 % |
|
20 K/h |
Air pressure during operation |
|
|
860 hPa (= 1 500 m above sea level) |
|
1 080 hPa |
Air pressure during storage |
|
|
660 hPa (= 3 500 m above sea level) |
|
1 080 hPa |
Ventilation |
Self ventilation or forced ventilation |
Mechanical ambient conditions |
|
Vibration during operation (stationary use) |
IEC 60068-2-6 Test FC (10 cycles per axis) |
|
0.075 m amplitude |
|
9.8 m/s2 (= 1 g constant acceleration) |
Vibration during transport/storage |
IEC 60068-2-6 Test FC (10 cycles per axis) |
|
3.5 mm amplitude |
|
9.8 m/s2 (= 1 g constant acceleration) |
Shock during operation (stationary use) |
IEC 60068 2 27 Test EA |
Shock during transport/storage |
IEC 60068 2 29 Test EB |
Electromagnetic compatibility |
|
Radio interference suppression (emitted interference) |
Limit value class A in accordance with EN 55011 Group 1 |
Immunity to conducted interference (burst) |
According to EN 61000-4-4 |
|
2 kV with switching network |
|
2 kV with clamp |
Immunity to conducted interference |
According to EN 61000 4 6: 10 V (0.15 to 80 MHz) |
Interference immunity to static electricity (ESD) |
Acc. to EN 61000-4-2 |
|
4 kV |
|
8 kV |
Immunity to high-frequency interference |
EN 61000 4 3 |
Immunity to high-energy pulses (surge) |
Acc. to EN 61000-4-5 |
Power supply lines |
|
|
1 kV |
|
2 kV |
PROFIBUS cable |
|
|
1 kV |