Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Overview
Drive Control Chart (DCC) expands the scope of device functions by means of freely available closed-loop control, calculation and logic modules and offers a means by which technological functions can be graphically configured in the SINAMICS S120 drive system. DCC is installed as a supplementary application to the STARTER commissioning tool.
Drive Control Chart expands the facility for the simplest possible configuring of technological functions both for the Motion Control System SIMOTION as well as for the SINAMICS S120 drive system. For users, this opens up a new dimension regarding the adaptability of the systems mentioned to the specific functions of their machines. DCC has no restrictions with regard to the number of usable functions; this is only limited by the performance capability of the target platform.
The user-friendly DCC editor enables easy graphics-based configuration, allows control loop structures to be clearly represented and provides a high degree of reusability of diagrams that have already been created.
The open-loop and closed-loop control functions are defined by using multi-instance-capable blocks (Drive Control Blocks (DCBs)) from a pre-defined library (DCB library) that are selected and graphically linked with one another by dragging and dropping. Test and diagnostic functions allow the program behavior to be verified and in the case of a fault, the cause identified.
The block library encompasses a large selection of closed-loop, arithmetic and logic blocks, as well as comprehensive open-loop and closed-loop control functions.
For logically combining, evaluating and acquiring binary signals, all commonly used logic functions are available for selection (AND, XOR, on/off delay, RS flipflop, counter, etc.). A wide range of arithmetic functions, such as absolute value generation, dividers and minimum/maximum evaluation are available to monitor and evaluate numerical quantities. In addition to the closed-loop drive control, axial winder functions, closed-loop PI controllers, ramp-function generators or wobble generators can be configured simply and easily.
Closed-loop control structures can be programmed with almost no restrictions in conjunction with the SIMOTION Motion Control System. These can then be combined with other program sections to form an overall program.
Drive Control Chart for SINAMICS S120 also provides a convenient basis for resolving drive-level open-loop and closed-loop control tasks directly in the converter. This further extends the possibility of adapting SINAMICS to the particular application. Local data processing in the drive supports the implementation of modular machine concepts and results in an increase in the overall machine performance.
Minimum hardware and software requirements
See the SCOUT or STARTER engineering software, since DCC is installed in addition to these programs.
Selection and ordering data
DCC comprises the graphical configuring tool (DCC Editor) and the block library (DCB Library).
DCC is installed in addition to the SCOUT or STARTER engineering software.
The necessary engineering license for each PC (floating) for DCC is acquired at the same time the order is placed; additional runtime licenses are not required.
DCC can be ordered in two versions: The version for SIMOTION and SINAMICS applications, or the version for SINAMICS applications only.
Order No. |
|
---|---|
DCC-SIMOTION/-SINAMICS V2.0 SP5 (single engineeering license, with DCC data carrier) DCC editor + DCB libraries for use on SIMOTION V4.1 SP5 and SINAMICS S120 V2.6 SP2 / V4.3 SP1 English, French, German, Italian (SIMOTION) English, French, German, Italian, Spanish (SINAMICS) |
6AU1810-1JA20-5XA0 |
DCC-SINAMICS V2.0 SP5 (single engineeering license, with DCC data carrier) DCC editor + DCB library for use on SINAMICS S120 V2.6 SP2 / V4.3 SP1 English, French, German, Italian, Spanish |
6AU1810-1HA20-5XA0 |