Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
1PH8 motor |
|
---|---|
Cooling |
Forced ventilation |
Ambient temperature, admissible |
-15 ... +40 °C |
Temperature monitoring |
KTY84 temperature sensor in stator winding |
Insulation of the stator winding in accordance with EN 60034-1 (IEC 60034-1) |
For an ambient temperature of up to 40 °C |
|
Temperature class 155 (F) |
Motor fan ratings |
|
|
230 V ± 10 %, 50 Hz |
|
400 V 3 AC ± 10 %, 50 Hz |
Encoder system, built-in |
DRIVE-CLiQ interface |
|
22 bit incremental encoder (resolution 4194304, internal 2048 S/R) + commutation position 11 bit (encoder IC22DQ)1) |
|
20 bit incremental encoder (resolution 1048576, internal 512 S/R) without commutation position (encoder IN20DQ)2) |
Sound pressure level
L
pA
(1 m)
|
Rated pulse frequency 4 kHz |
|
70 dB |
|
72 dB |
Connection |
|
|
Terminal box |
|
|
|
Power connector |
|
Terminals in terminal box |
|
Connector for signals (without mating connector) or DRIVE-CLiQ |
Vibration magnitude |
In accordance with Siemens/EN 60034-14 (IEC 60034-14) |
Shaft and flange accuracy3) |
In accordance with Siemens/DIN 42955 (IEC 60072-1) |
Degree of protection in accordance with |
|
|
IP55 |
|
IP55 |
Rating plate |
1 unit attached to motor |
Paint finish |
Anthracite RAL 7016 |
Approvals, according to |
cURus |
1) Maximum speednmax = 12000 rpm.
2) Maximum speednmax = 15000 rpm.
3) Shaft extension run-out, concentricity of centering ring and shaft, and perpendicularity of flange to shaft.
Terminal box assignment, max. connectable conductor cross-sections
1PH8 motor |
Terminal box |
Cable entry |
Outer cable diameter, max.4) |
Number of main terminals |
Cross-section per terminal, max. |
Rated current, max.5) |
||
---|---|---|---|---|---|---|---|---|
Type |
Type |
Power |
External signals |
|||||
mm |
mm2 |
A |
||||||
1PH808 |
Forced ventilation |
gk803 |
1 M25 1.5 |
1 O 22 mm6) |
20 |
Phases: 3 M5 |
1 10 |
50 |
1PH810 |
Forced ventilation |
gk813 |
1 M32 1.5 |
1 O 22 mm6) |
24.2 |
Phases: 3 M5 |
1 16 |
66 |
1PH813 |
Forced ventilation |
gk833 |
1 M40 1.5 |
1 O 22 mm6) |
32 |
Phases: 3 M6 |
1 35 |
104 |
4) Dependent on the design of the metric cable gland.
5) Current-carrying capacity based on EN 60204-1 and IEC 60364-5-52, according to installation type C.
6) Hole with diameter 22 mm, at 90° to signal connection.