The following are located on the TM54F Terminal Module:
- 4 fail-safe digital outputs
- 10 fail-safe digital inputs
- 4 LEDs, single color for indicating the status of the read back channel of the fail-safe digital outputs
- 4 LEDs, dual-color for indicating the status of the fail-safe digital outputs
- 20 LEDs, dual-color for indicating the status of the fail-safe digital inputs
- 3 LEDs, single color for indicating the status of the 24 V sensor supplies
- 2 DRIVE-CLiQ sockets
- 2 connections for 24 V sensor supply, switchable
- 1 connection for 24 V sensor supply, not switchable
- 1 connection for the electronics power supply via the 24 V DC power supply connector
- 1 connection for the 24 V power supply to digital outputs and sensors
- 1 PE/protective conductor connection
The TM54F Terminal Module can be snapped onto a TH 35 top-hat rail according to EN 60715 (IEC 60715).
The signal cable shield can be connected to the TM54F Terminal Module via a shield connection terminal, e.g. Phoenix Contact type SK8 or Weidmuller type KLBU CO 1. The shield connection terminal must not be used for strain relief.
The status of the TM54F Terminal Module is indicated via a multi-color LED.
Pins for connector coding are included in the scope of supply of the TM54F Terminal Module.