Field data (operating/limit distance) of transponders and readers (all specifications in mm)
The following table shows the field data (unaffected by metal) for all ISO transponders (MDS Dxxx) in connection with RF200 readers. The listed technical data are typical values and are valid for a room temperature of +25 °C.
MDS D165 |
MDS D261 |
MDS D100 |
MDS D200 |
MDS D124 |
MDS D139 |
MDS D160 |
MDS D324 |
|
---|---|---|---|---|---|---|---|---|
SIMATIC RF210R |
- |
- |
- |
- |
5 … 16/18 |
- |
2 … 10/12 |
2 … 8/9 |
SIMATIC RF220R |
10 … 36/44 |
10 … 30/35 |
10 … 35/40 |
10 … 35/40 |
5 … 16/18 |
10 … 35/40 |
5 … 20/22 |
10 … 20/25 |
SIMATIC RF260R |
40 … 120/135 |
20 … 75/90 |
40 … 110/130 |
30 … 100/120 |
10 … 40/48 |
20 … 80/110 |
10 … 40/45 |
20 … 60/70 |
MDS D424 |
MDS D428 |
MDS D460 |
MDS D421 |
MDS D126 |
MDS D426 |
MDS D422 |
MDS D425 |
|
---|---|---|---|---|---|---|---|---|
SIMATIC RF210R |
2 … 10/12 |
2 … 10/12 |
2 … 8/9 |
1 … 2/4 |
- |
- |
2 … 6/7 |
3 … 7/8 |
SIMATIC RF220R |
10 … 25/28 |
5 … 18/20 |
5 … 18/20 |
1 … 5/6 |
8 … 25/28 |
10 … 30/35 |
3 … 9/10 |
5 … 12/14 |
SIMATIC RF260R |
10 … 60/70 |
5 … 30/40 |
10 … 35/40 |
- |
15 … 55/75
|
20 … 70/90 |
- |
- |
–: Reader-transponder combination not released
For detailed descriptions and detailed technical data of the ISO transponders MDS Dxxx: See MOBY D.