Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Application |
|
Gauge measurement |
Liquids, gases and vapors |
Mode of operation |
|
Measuring principle |
Piezoresistive measuring cell (stainless steel diaphragm) |
Measured variable |
Gauge pressure |
Input |
|
Measuring range |
|
|
100 … 600 mbar (1.45 … 8.7 psi g) |
Output |
|
Current signal |
4 ... 20 mA |
|
(UB - 10 V) / 0.02 A |
|
7 ... 33 V DC (10 ... 30 V for Ex) |
Voltage signal |
0 ... 10 V DC |
|
10 k |
|
12 ... 33 V DC |
|
< 7 mA at 10 k |
Characteristic curve |
Linear rising |
Measuring accuracy |
|
Error in measurement at limit setting incl. hysteresis and reproducibility |
|
Step response time T99 |
< 5 ms |
Long-term stability |
|
|
0.25 % of full-scale value/year |
Influence of ambient temperature |
|
|
|
|
0.005 %/V |
Rated conditions |
|
Pressure transmitter with gasket made of: |
|
|
-15 ... +125 °C (+5 ... +257 °F) |
|
-35 ... +100 °C (-31 ... +212 °F |
|
-20 ... +100 °C (-4 ... +212 °F) |
|
-40 ... +145 °C (-40 ... +293 °F), |
Ambient temperature |
-25 ... +85 °C (-13 ... +185 °F) |
Storage temperature |
-50 ... +100 °C (-58 ... +212 °F) |
Degree of protection (to EN 60529) |
|
Electromagnetic Compatibility |
|
Mounting position |
Vertical, facing up |
Design |
|
Weight |
Approx. 0.090 kg (0.198 lb) |
Process connections |
See dimension drawings |
Electrical connections |
|
Wetted parts materials |
|
|
Stainless steel, mat.-No. 1.4435 |
|
Stainless steel, mat. no. 1.4404 (SST 316 L) |
|
|
Non-wetted parts materials |
|
|
Stainless steel, mat. no. 1.4404 (SST 316 L) |
|
Plastic |
|
PVC |
Certificates and approvals |
|
Classification according to pressure equipment directive (PED 97/23/EC) |
For gases of fluid group 1 and liquids of fluid group 1; meets requirements as per article 3, paragraph 3 (good engineering practice) |
Lloyds Register of Shipping (LR) |
Applied |
Germanischer Lloyds Register of Shipping |
Applied |
American Bureau of Shipping (ABS) |
Applied |
Bureau Veritas (BV) |
Applied |
Det Norske Veritas (DNV) |
Applied |
Drinking water approval (ACS) |
Applied |
GOST |
Applied |
Explosion protection |
|
Intrinsic safety "i" (only with current output) |
Ex II 1/2 G Ex ia IIC T4 GA/gb Ex II 1/2 D Ex ia IIIC T125 °C Da/Db |
EC type-examination certificate |
SEV 10 ATEX 0146 |
Connection to certified intrinsically-safe resistive circuits with maximum values |
Ui 30 V DC; Ii = 100 mA; Pi 0.75 W |
Effective internal inductance and capacity for versions with plugs per EN 175301-803-A and M12 |
Li = 0 nH; Ci = 0 nF |