Order No. |
6NH7 803-4BA00-0AA0 |
Product type designation |
TIM 4R-IE DNP3 |
Transmission rate |
|
Transmission rate |
|
|
10 … 100 Mbit/s |
|
300 … 115 200 bit/s |
Interfaces |
|
Number of interfaces in accordance with Industrial Ethernet |
2 |
Number of electrical connections |
|
|
2 |
|
1 |
Design of electrical connection |
|
|
RJ45 port |
|
9-pin Sub-D connector, RS232 switchable to RS485 |
|
9-pin Sub-D connector, RS232 switchable to RS485 |
|
2-pin, plug-in terminal strip |
Design of swap medium C-Plug |
Yes |
Supply voltage, current consumption, power loss |
|
Type of power supply |
DC |
Supply voltage |
24 V |
|
20.4 V |
|
28.8 V |
Current consumed |
|
|
0.2 A |
|
0.17 A |
Effective power loss |
4.6 W |
Product expansion: optional backup battery |
Yes |
Type of battery |
Lithium AA / 3.6 V / 2.3 Ah |
Backup current |
|
|
100 µA |
|
160 µA |
Permissible ambient conditions |
|
Ambient temperature |
|
|
0 … 60°C |
|
-40 … +70°C |
|
-40 … +70°C |
Relative humidity at 25 °C without condensation during operation, maximum |
95 % |
IP degree of protection |
IP20 |
Design, dimensions and weights |
|
Module format |
Compact module S7-300 double-width |
Width |
80 mm |
Height |
125 mm |
Depth |
120 mm |
Net weight |
0.4 kg |
Product properties, functions, componentsGeneral |
|
Number of modules - Note |
Number of TIMs per S7-300 / S7-400: 1 |
Cable length |
|
|
6 m |
|
30 m |
Performance data |
|
Performance dataS7 communication |
|
Number of possible connections for S7 communication |
|
|
5 |
|
2 |
|
1 |
Number of possible connections for S7 communication - Note |
Only via LAN |
Service |
|
|
- |
|
Yes |
Performance datamultiprotocol operation |
|
Number of active connections in multiprotocol mode |
- |
Performance dataTelecontrol |
|
Suitability for use |
|
|
No |
|
Yes |
|
No |
Suitability for use - Note |
- |
Protocol is supported |
|
|
No |
|
Yes |
|
No |
|
No |
Number of DNP3 masters |
|
|
8 |
|
1 |
Product function: data buffering if connection is aborted |
Yes |
|
200,000 data points with one master |
Product functionsManagement, configuration, programming |
|
Configuration software required |
SINAUT ST7 ES |
Storage location of TIM configuration data |
on the CPU or TIM |
Product functionsTime |
|
Product component: hardware real-time clock |
Yes |
Product property: buffered hardware real-time clock |
Yes |
Maximum accuracy of hardware real-time clock per day |
4 s |