IFN VIB-ACC |
|
Communication (LNK0…LNK2) |
|
Number |
3 |
Connector |
Female connector 8-pole (M12) |
Protocol |
IEEE1394a / b |
Data transfer rate |
400 Mbps |
Electrical isolation |
No |
Power supply (PWR) |
|
Connector |
Male connector 5-pole (M12) |
DC input voltage |
19.2 … 32 V |
DC overvoltage protection |
Max. 35 V |
DC current consumption |
Typ. 0.2 A at 24 V DC |
Reverse polarity protection |
Yes |
Power supply |
Stabilized |
DC power consumption |
Typ. 4.8 W |
Electrical isolation |
No |
Measuring inputs (CH1…CH6) |
|
Number |
6 |
Connector |
Female connector 5-pole (M12) |
Resolution |
16 bits (15 + sign) |
DC overvoltage protection |
±60 V |
Postscanning (parameterizable in X-Tools) |
0.014 / 0.33 / 4 / 8 / 16 / 24 / 48 / 64 / 96 kHz |
IEPE sensor input (CH1…CH6) |
|
Crosstalk attenuation (CTA) |
-70 dB at 1 kHz |
Signal-to-noise ratio (SNR) |
-70 dB |
Scanning frequency |
192 kHz |
Input frequency range |
0.0001 … 40 kHz |
Accuracy |
± 0,7 % |
Electrical isolation |
No |
Cable open-circuit monitoring |
Yes |
Cable short-circuit monitoring |
Yes |
Analog input (CH6) |
|
DC input voltage |
±30 V |
DC input frequency range |
0 … 1 kHz |
Crosstalk attenuation (CTA) |
-78 dB at 1 kHz |
Signal-to-noise ratio (SNR) |
-69 dB |
Scanning frequency |
192 kHz |
Accuracy |
± 1 % |
Cable open-circuit monitoring |
No |
Cable short-circuit monitoring |
No |
Functional ground |
|
Connection |
M4 screw with contact washer |
Cable cross-section |
2.5 mm2 |
Connecting cable |
|
Communication |
Pre-assembled 8-pole cable (shielded)1) |
Signal inputs |
Pre-assembled 5-pole cable (shielded)1) |
Power supply |
Pre-assembled 5-pole cable (shielded)1) |
Environmental conditions |
|
Operating temperature |
-40 ... +65 °C |
Storage/transport temperature |
-40 ... +85 °C |
Degree of protection |
IP67 |
Constructional details |
|
Enclosure |
Aluminum |
Dimensions incl. connector (H x W x D) in mm |
210 x 86 x 87 (without assembly) |
Mounting |
Standard: DIN rail (DIN EN 60715 TH35-15) |
Minimum clearances (front, top, bottom) in mm |
80, 25, 25 |
Weight |
Approx. 1240 g |
Approvals |
|
CE |
Industrial environment |
1) See Operating Instructions for accessories (not included in scope of delivery)