Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2012
архивный
(4872) 700-366
skenergo@mail.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Power cables

Power cables

MOTION CONNECT 500

MOTION CONNECT 800

6FX500.-....-....

6FX800.-.....-....

Approvals, according to

  • VDE1)/RoHS conformity

Yes

Yes

  • cURus or UR/CSA2)

UL758-CSA-C22.2-N.210.2-M90

UL758-CSA-C22.2-N.210.2-M90

Rated voltage U0/U

  • Power conductors

600 V/1000 V

600 V/1000 V

  • Signal conductors

24 V (EN) 1000 V (UL/CSA)

24 V (EN) 1000 V (UL/CSA)

Test voltage, rms

  • Power conductors

4 kV

4 kV

  • Signal conductors

2 kV

2 kV

Operating temperature on the surface

  • Fixed installation

-20 … +80 °C ( 4 ... +176 °F)

-50 … +80 °C ( 58 ... +176 °F)

  • Flexible installation

0 … 60 °C (32 ... 140 °F)

-20 … +60 °C ( 4 ... +140 °F)

Tensile stress, max.

  • Fixed installation

50 N/mm2 (7252 lbf/in2)

50 N/mm2 (7252 lbf/in2)

  • Flexible installation

20 N/mm2 (2901 lbf/in2)

20 N/mm2 (2901 lbf/in2)

Smallest bending radius

  • Fixed installation

5   Dmax

6   Dmax

  • Flexible installation

See power cables

See power cables

Torsional stress

Absolute 30°/m

Absolute 30°/m

Bending

100000

10 million
from 10 mm2: 3 million

Traversing velocity

30 m/min (98.43 ft/min)

180 m/min (591 ft/min)
from 10 mm2: 100 m/min (328 ft/min)

Acceleration

2 m/s2 (6.56 ft/s2)

5 m/s2 (16.41 ft/s2) (5 m (16.41 ft)) /
10 m/s2 (32.81 ft/s2) (2.5 m (8.20 ft))

Insulation material, incl. jacket

CFC/silicone-free

CFC/halogen/silicone-free
IEC 60754 1/DIN VDE 0472-815

Oil resistance

EN 60811-2-1
(mineral oil only)

EN 60811-2-1

Outer jacket

PVC

PUR, HD22.10 S2 (VDE 0282, Part 10)

DESINA color orange RAL 2003

DESINA color orange RAL 2003

Flame-retardant

EN 60332-1-1 to 1-3

EN 60332-1-1 to 1-3


1) The respective registration number is printed on the cable jacket.

2) The UR-CSA File No. is printed on the cable jacket.

Power cables for 1FK7 motors with SPEED-CONNECT connector

Connection method,
Power/Motor
Module end

No of cores  cross-section

Connector size, motor end

Pre-assembled cable
with
SPEED-CONNECT connector

D max

Cable sold by the meter1)

Weight
(without connector)

Smallest perm. bending radius2)

6FX5

6FX8

6FX5

6FX8

6FX5

6FX8

mm2

Order No.

mm (in)

mm (in)

Order No.

kg/m (lb/ft)

kg/m (lb/ft)

mm (in)

mm (in)

1FK7 motorswithout brake on SINAMICS S120Combi Power Modules

Exposed core ends3)

4   1.5

1

6FX002 5CF10 ....

8.4 (0.33)

9.5 (0.37)

6FX008 1BB11 ....

0.12 (0.08)

0.16 (0.11)

155 (6.10)

75 (2.95)

1.5

6FX002 5CF14 ....

1FK7 motorswith brake on SINAMICS S120Combi Power Modules

Exposed core ends3)

4   1,5 + 2   1,5

1

6FX002 5DF10 ....

10.8 (0.43)

12 (0.47)

6FX008 1BA11 ....

0.22 (0.15)

0.25 (0.17)

195 (7.68)

90 (3.54)

1.5

6FX002 5DF14 ....

1FK7 motorswithout brake on SINAMICS S120Motor Modules in booksize compact format

Exposed core ends

4   1.5

1

6FX002 5CG10 ....

8.4 (0.33)

9.5 (0.37)

6FX008 1BB11 ....

0.12 (0.08)

0.16 (0.11)

155 (6.10)

75 (2.95)

1.5

6FX002 5CG22 ....

4   2.5

1

6FX002 5CG12 ....

10 (0.39)

11 (0.43)

6FX008 1BB21 ....

0.21 (0.14)

0.23 (0.16)

180 (7.09)

90 (3.54)

1.5

6FX002 5CG32 ....

1FK7 motorswith brake on SINAMICS S120Motor Modules in booksize compact format

Exposed core ends

4   1.5 + 2   1.5

1

6FX002 5DG10 ....

10.8 (0.43)

12 (0.47)

6FX008 1BA11 ....

0.22 (0.15)

0.25 (0.17)

195 (7.68)

90 (3.54)

1.5

6FX002 5DG22 ....

4   2.5 + 2   1.5

1

6FX002 5DG12 ....

12.4 (0.49)

13.8 (0.54)

6FX008 1BA21 ....

0.25 (0.17)

0.31 (0.21)

225 (8.86)

105 (4.13)

MOTION CONNECT 500

       5

       5

MOTION CONNECT 800

       8

       8

Length code

                             ....

                            ....


1) Note type of delivery.

2) Valid for installation in a cable carrier.

3) Length of core ends for power is 55 mm (2.17 in) and length of brake core ends is 250 mm (9.84 in).

Power cables for 1PH8 motors with terminal box

Motor

Thread

No of cores  cross-section

Connection method,
Power/Motor Module end

Pre-assembled cable

D max

Cable sold by the meter1)

Weight
(without cable gland)

Smallest perm. bending radius2)

6FX5

6FX8

6FX5

6FX8

6FX5

6FX8

Type

mm2

Order No.

mm (in)

mm (in)

Order No.

kg/m (lb/ft)

kg/m (lb/ft)

mm (in)

mm (in)

1PH8 motors with terminal box on SINAMICS S120Combi Power Modules

1PH808

M25

4   2.5

Exposed core ends3)

6FX002 5CE02 ....

11 (0.43)

11 (0.43)

6FX8008 1BB21 ....

0.21 (0.14)

0.23 (0.16)

180 (7.09)

90 (3.54)

1PH810

M32

4   4

Exposed core ends3)

6FX002 5CE04 ....

11.4 (0.45)

12.3 (0.48)

6FX8008 1BB31 ....

0.27 (0.18)

0.31 (0.21)

210 (8.27)

100 (3.94)

1PH813

M40

4   6

Exposed core ends3)

6FX002 5CE06 ....

20 (0.79)

15.1 (0.59)

6FX8008 1BB51 ....

0.37 (0.25)

0.42 (0.28)

245 (9.65)

120 (4.72)

1PH8 motors with terminal box on SINAMICS S120Motor Modules in booksize compact format

1PH808

M25

4   2.5

Exposed core ends4)

6FX8002 5CR10 ....

11 (0.43)

6FX8008 1BB21 ....

0.23 (0.16)

90 (3.54)

1PH810

M32

4   2.5

Exposed core ends4)

6FX8002 5CR11 ....

11 (0.43)

6FX8008 1BB21 ....

0.23 (0.16)

90 (3.54)

MOTION CONNECT 500

       5

MOTION CONNECT 800

       8

       8

Length code

                             ....

                            ....


1) Note type of delivery.

2) Valid for installation in a cable carrier.

3) Length of core ends for power is 55 mm (2.17 in) and length of brake core ends is 250 mm (9.84 in).

4) Length of core ends 300 mm (11.81 in). 4 M8 cable lugs and 4 M6 cable lugs are also included in the scope of supply of the cables.
























































  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366
Яндекс.Метрика