Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Diaphragm seals (flange design) for guage and absolute pressure, directly fitted on a transmitter |
|
Nominal diameter |
Nominal pressure |
|
PN 40, PN 100 |
|
PN 40, PN 100 |
|
PN 16, PN 40 |
|
Class 150, class 300, class 600, class 1500 |
|
Class 150, class 300, class 600 |
|
Class 150, class 300, class 400 |
Sealing face |
|
|
To EN 1092-1, form B1 or ASME B16.5 RF 125 ... 250 AA |
|
Smooth to EN 1092-1, form B2 or ASME B16.5 RFSF |
Materials |
|
|
Stainless steel, Mat. No. 1.4404/316L |
|
Stainless steel, Mat. No. 1.4404/316L |
|
|
|
|
|
|
|
|
Monel 400, mat. no. 2.4360 |
|
Hastelloy C276, mat. no. 2.4819 |
|
Hastelloy C4, mat. no. 2.4610 |
|
Tantalum |
|
|
Stainless steel 1.4571/316Ti |
|
copper |
Maximum pressure |
See above and the technical data of the transmitter |
Tube length |
|
Capillary |
|
|
Max. 10 m (32.8 ft), longer lengths on request |
|
2 mm (0.079 inch) |
|
150 mm (5.9 inch) |
Filling liquid |
|
Max. recommended process temperature |
170 °C (338 °F) |
Permissible ambient temperature |
Dependent on the pressure transmitter and the filling liquid of the remote seal. More information can be found in the technical specifications of the pressure transmitters and in the section "Technical data of filling liquid" in the introduction to the remote seals. |
Weight |
Approx. 4 kg (8.82 lb) |
Certificates and approvals |
|
Classification according to pressure equipment directive (PED 97/23/EC) |
For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) |