For gauge and absolute pressure, with flush-mounted diaphragm

SITRANS P pressure transmitters, DS III series for gage pressure, with flush-mounted diaphragm, dimensions in mm (inch)

The diagram shows a SITRANS P DS III with an example of a flange. In this drawing the height is subdivided into H1 and H2.

H1 = Height of the SITRANS P300 up to a defined cross-section

H2 = Height of the flange up to this defined cross-section

Only the height H2 is indicated in the dimensions of the flanges.

Flanges as per EN and ASME

Flange to EN

EN 1092-1

DN

PN

D

H2

25

40

115 mm (4.5")

Approx. 52 mm (2")

25

100

140 mm (5.5")

40

40

150 mm (5.9")

40

100

170 mm (6.7")

50

16

165 mm (6.5")

50

40

165 mm (6.5")

80

16

200 mm (7.9")

80

40

200 mm (7.9")


Flanges to ASME

ASME B16.5

DN

Class

D

H2

1“

150

110 mm (4.3")

Approx. 52 mm (2")

1“

300

125 mm (4.9")

1 “

150

130 mm (5.1")

1 “

300

155 mm (6.1")

2“

150

150 mm (5.9")

2“

300

165 mm (6.5")

3“

150

190 mm (7.5")

3“

300

210 mm (8.1")

4“

150

230 mm (9.1")

4“

300

255 mm (10.0")


F&B and pharmaceutical flanges

Connections to DIN

DIN 11851 (milk pipe union)

DN

PN

D

H2

50

25

92 mm (3.6")

Approx. 52 mm (2")

80

25

127 mm (5.0")


TriClamp to DIN 32676

DN

PN

D

H2

50

16

64 mm (2.5")

Approx. 52 mm (2")

65

16

91 mm (3.6")


Other connections

Varivent connection

DN

PN

D

H2

40 ... 125

40

84 mm (3.3")

Approx. 52 mm (2")


Biocontrol connection

DN

PN

D

H2

50

16

90 mm (3.5")

Approx. 52 mm (2")

65

16

120 mm (4.7")


Sanitary process connection to DRD

DN

PN

D

H2

65

40

105 mm (4.1”)

Approx. 52 mm (2")


Sanitary process screw connection to NEUMO Bio-Connect

DN

PN

D

H2

50

16

82 mm (3.2")

Approx. 52 mm (2")

65

16

105 mm (4.1”)

80

16

115 mm (4.5”)

100

16

145 mm (5.7")

2”

16

82 mm (3.2")

2 ”

16

105 mm (4.1”)

3”

16

105 mm (4.1”)

4”

16

145 mm (5.7")


Sanitary process connection to NEUMO Bio-Connect flange connection

DN

PN

D

H2

50

16

110 mm (4.3")

Approx. 52 mm (2")

65

16

140 mm (5.5”)

80

16

150 mm (5.9”)

100

16

175 mm (6.9")

2”

16

100 mm (3.9")

2 ”

16

110 mm (4.3”)

3”

16

140 mm (5.5”)

4”

16

175 mm (6.9")


Sanitary process connection to NEUMO Bio-Connect clamp connection

DN

PN

D

H2

50

16

77.4 mm (3.0")

Approx. 52 mm (2")

65

10

90.9 mm (3.6")

80

10

106 mm (4.2")

100

10

119 mm (4.7")

2”

16

64 mm (2.5")

2 ”

16

77.4 mm (3.0”)

3”

10

90.9 mm (3.6”)

4”

10

779 mm (4.7")


Sanitary process connection to NEUMO Bio-Connect S flange connection

DN

PN

D

H2

50

16

125 mm (4.9")

Approx. 52 mm (2")

65

10

145 mm (5.7")

80

10

155 mm (6.1")

100

10

180 mm (7.1")

2”

16

125 mm (4.9")

2 ”

10

135 mm (5.3”)

3”

10

145 mm (5.7")

4”

10

180 mm (7.1")


Threaded connection G ", G1" and G2" acc. to DIN 3852

DN

PN

D

H2

63

37 mm (1.5")

approx. 45 mm (1.8")

1“

63

48 mm (1.9")

approx. 47 mm (1.9")

2“

63

78 mm (3.1")

Approx. 52 mm (2")


Tank connection TG 52/50 and TG52/150

DN

PN

D

H2

25

40

63 mm (2.5")

approx. 63 mm (2.5")

25

40

63 mm (2.5")

approx. 170 mm (6.7")


SMS socket with union nut

DN

PN

D

H2

2“

25

84 mm (3.3")

Approx. 52 mm (2.1")

2 “

25

100 mm (3.9")

3“

25

114 mm (4.5")


SMS threaded socket

DN

PN

D

H2

2“

25

70 x 1/6 mm

Approx. 52 mm (2.1")

2 “

25

85 x 1/6 mm

3“

25

98 x 1/6 mm


IDF socket with union nut

DN

PN

D

H2

2“

25

77 mm (3")

Approx. 52 mm (2.1")

2 “

25

91 mm (3.6")

3“

25

106 mm (4.2")


IDF threaded socket

DN

PN

D

H2

2“

25

64 mm (2.5")

Approx. 52 mm (2.1")

2 “

25

77.5 mm (3.1")

3“

25

91 mm (3.6")


Aseptic threaded socket to DIN 11864-1 Form A

DN

PN

D

H2

50

25

94

Approx. 52 mm (2.1")

65

25

113

80

25

133

100

25

159


Aseptic flange with notch to DIN 11864-2 Form A

DN

PN

D

H2

50

16

78 x 1/6"

Approx. 52 mm (2.1")

65

16

95 x 1/6"

80

16

110 x 1/4"

100

16

130 x 1/4"


Aseptic flange with groove to DIN 11864-2 Form A

DN

PN

D

H2

50

16

94

Approx. 52 mm (2.1")

65

16

113

80

16

133

100

16

159


Aseptic clamp with groove to DIN 11864-3 Form A

DN

PN

D

H2

50

25

77,5

Approx. 52 mm (2.1")

65

25

91

80

16

106

100

16

130
























































Каталог оборудования
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Контрольно-измерительные приборы Pressure gauge Transmitter for gauge, absolute and differ. pressure, flow and level Measurement transducer for basic requirements Transmitter with WirelessHART communication Transmitters for food, pharmaceuticals and biotechnology Transmitter for gauge pressure for the paper industry Transmitter for general requirements SITRANS P DS III, technical description For gauge pressure For gauge and absolute pressure, with flush-mounted diaphragm For absolute pressure (from the gauge pressure series) For absolute pressure (from the differential pressure series) For differential pressure and flow For filling level Accessories Transmitter for high-end requirements Remote seals for transmitters and pressure gauges Fittings Датчики давления Приборы измерения температуры SITRANS T Расходомеры Уровнемеры Расходомеры и счетчики Позиционеры Устройство для защиты и пуска двигателей SIMOCODE-DP Блок питания/искробезопасной развязки датчиков SITRANS I Источники питания и разделители Сигнализаторы сбоев в промышленном процессе Аппаратные ПИД-регуляторы SIPART Встраиваемые самописцы и индикаторы Коммуникации и программное обеспечение Анализаторы процесса Технологии взвешивания Датчики зрения Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо