Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Order No. |
6XV1 830-5HH10 |
6XV1 830-5GH10 |
Product type designation |
Foundation Fieldbus cable |
Foundation Fieldbus Cable |
Product description |
Bus cable (2-core), sold by the meter, in bulk |
Bus cable (2-core), sold by the meter, in bulk |
Suitability for application |
Use for fieldbus systems in accordance with IEC 61158-2 (e.g. Foundation Fieldbus), suitable for non-hazardous applications |
Use for fieldbus systems in accordance with IEC 61158-2 (e.g. Foundation Fieldbus), suitable for hazardous applications |
Cable designation |
2X(ST)CY 1X2X1.1/2.85-100 LI GE FR OE |
2X(ST)CY 1X2X1.1/2.85-100 LI BL FR OE |
Cable length |
- |
- |
Electrical specifications |
||
Attenuation factor per length |
||
|
- |
- |
|
0.003 dB/m |
0.003 dB/m |
|
- |
- |
|
- |
- |
Characteristic impedance |
||
|
100 |
100 |
|
- |
- |
|
100 |
100 |
|
- |
- |
Relative symmetrical tolerance |
||
|
- |
- |
|
20 % |
20 % |
|
- |
- |
Max. loop resistance per length |
46 /km |
46 /km |
Max. shield resistance per length |
10 /km |
10 /km |
Capacitance per length at 1 kHz |
65 pF/m |
65 pF/m |
Operating voltage, rms value |
300 V |
300 V |
Mechanical data |
||
Number of electrical cores |
2 |
2 |
Design of shield |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires with shield wire |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires with shield wire |
Design of electrical connection FastConnect |
No |
No |
Outer diameter |
||
|
1.17 mm |
1.17 mm |
|
2.85 mm |
2.85 mm |
|
6.4 mm |
6.4 mm |
|
8.5 mm |
8.5 mm |
Symmetrical tolerance of outer diameter of cable sheath |
0.3 mm |
0.3 mm |
Outer diameter of cable sheath - Note |
- |
- |
Material |
||
|
PE |
PE |
|
- |
- |
|
PVC |
PVC |
|
- |
- |
Color |
||
|
blue / brown |
blue / brown |
|
Yellow |
Blue |
Bending radius |
||
|
34 mm |
34 mm |
|
68 mm |
68 mm |
|
- |
- |
Number of bending cycles |
- |
- |
|
- |
- |
Number of torsion cycles with torsion by ± 180° on 1 m cable length |
- |
- |
Maximum tensile load |
100 N |
100 N |
Weight per length |
98 kg/km |
98 kg/km |
Permitted ambient conditions |
||
Ambient temperature |
||
|
-40 … +105 °C |
-40 … +105 °C |
|
-40 … +105 °C |
-40 … +105 °C |
|
-40 … +105 °C |
-40 … +105 °C |
|
-40 … +105 °C |
-40 … +105 °C |
Ambient conditions for operation |
Transmission rate of the cable: 31.25 kbit/s |
Transmission rate of the cable: 31.25 kbit/s |
IP degree of protection |
- |
- |
Behavior in fire |
Flame-retardant in accordance with IEC 60332-1-2 |
Flame-retardant in accordance with IEC 60332-1-2 |
Chemical resistance |
||
|
Limited resistance |
Limited resistance |
|
Limited resistance |
Limited resistance |
|
- |
- |
Radiological resistance against UV radiation |
Resistant |
Resistant |
Product properties, functions, components General |
||
Product property |
||
|
No |
No |
|
Yes |
Yes |
Cable length |
||
|
- |
- |
|
- |
- |
Standards, specifications, approvals |
||
UL listing at 300 V rating |
Yes: CMG / PLTC# / Sun Res |
Yes: CMG / PLTC / Sun Res |
UL style at 600 V rating |
No |
No |
Certificate of suitability |
- |
- |
|
Yes |
Yes |
Marine classification society |
||
|
No |
No |
|
No |
No |