Rated input voltage |
Typ. rated motor power of the units |
---|---|
400 V |
2 - 105 kW |
500 V |
2 - 105 kW |
1~AC 230V supply - using either UPS or 100V - 400V DC from a battery possible, for evacuation operation when the line supply fails |
Brief overview |
|
---|---|
Setting, diagnostics |
Operator panel connected to Dynavert L, LEDs, serial interface |
Control commands |
Contacts or 24 V control signals (PLC-compatible for travel commands and other digital input), DCP interface |
Motor types |
Synchronous / induction – gearless or with gear |
Signal outputs: |
Isolated contacts, 250 V AC /1A, DCP interface |
Speed feedback for synchronous motors |
1 V-PP signal level (max. 10 m encoder cable) |
Speed feedback for induction motors |
Encoder with HTL signal level or TTL signal level, the pulse number can be parameterized, |
Open-loop operation |
Possible with induction motors up to 1.2 m/s elevator cabin speed |
Mechanical degree of protection |
IP20 |
Ambient temperature, storage |
-25 … +70 °C |
Ambient temperature, operation |
0 … + 45 °C |
Installation height |
1000 m above sea level; above this altitude, the drive unit utilization must be reduced by 10 % for every 1000 m |
Cooling |
Direct forced air cooling, automatic temperature control |