Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2012
архивный
(4872) 700-366
skenergo@mail.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
SCALANCE X-200IRT managed

Order No.

6GK5 200-4AH00-2BA3

6GK5 201-3BH00-2BA3

6GK5 202-2BH00-2BA3

Product type designation

SCALANCE X200-4P IRT

SCALANCE X201-3P IRT

SCALANCE X202-2P IRT

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

Interfaces

Number of electrical/optical connections

  • for network components or terminal equipment maximum

4

4

4

  • as combo port for network components or terminal equipment

-

-

-

Number of electrical connections

  • for network components and terminal equipment

-

1

2

  • for alarm contact

1

1

1

  • for power supply

1

1

1

  • for redundant power supply

1

1

1

Design of electrical/optical connections for network components or terminal equipment

Design of electrical connection

  • for network components and terminal equipment

-

RJ45 port

RJ45 port

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

Number of optical interfaces for optical waveguide at 100 Mbit/s

4

3

2

Design of optical interface for optical waveguide at 100 Mbit/s

SC-RJ/POF port

SC-RJ/POF port

SC-RJ/POF port

Connectable optical power relative to 1 mW

  • of the transmitter output

-8 ... -2 dB

-8 ... -2 dB

-8 ... -2 dB

  • of the receiver input maximum

-

-

-

Optical sensitivity relative to 1 mW of the receiver input minimum

-25 dB

-25 dB

-25 dB

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

0 … 0.05 km

0 … 0.05 km

0 … 0.05 km

design of the removable storage C-PLUG

Yes

Yes

Yes

Inputs/outputs

Operating current of signaling contacts at AC maximum

-

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

Type of voltage of supply voltage

DC

DC

DC

Supply voltage external

24 V

24 V

24 V

  • minimum

18 V

18 V

18 V

  • maximum

32 V

32 V

32 V

Product component fusing at power supply input

Yes

Yes

Yes

Type of fusing at input for supply voltage

Consumed current maximum

0.4 A

0.35 A

0.3 A

Active power loss at 24 V for DC

9.6 W

8.4 W

7.2 W

Permitted ambient conditions

Ambient temperature

  • during operating

-25 … +40 °C

-25 … +50 °C

-25 … +60 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • Comment

-

-

-

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

Protection class IP

IP30

IP30

IP30

Design, dimensions and weight

Design

Compact

Compact

Compact

Width

60 mm

60 mm

60 mm

Height

125 mm

125 mm

125 mm

Depth

124 mm

124 mm

124 mm

Net weight

0.78 kg

0.78 kg

0.78 kg

Type of mounting

  • 35 mm DIN rail mounting

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Type of mounting

-

-

-

Product properties, functions, componentsgeneral

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

Product function

  • CLI

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

  • Port mirroring

No

No

No

  • for IRT PROFINET IO switch

Yes

Yes

Yes

  • PROFINET IO diagnosis

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

  • BOOTP

No

No

No

  • SNMP v1

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Product functionsDiagnosis

Product function

  • Port diagnostics

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Product functionsDHCP

Product function DHCP client

Yes

Yes

Yes

Product functionsRedundancy

Product function

  • Ring redundancy

Yes

Yes

Yes

  • Redundancy manager

Yes

Yes

Yes

  • Standby redundancy

Yes

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

Yes

  • redundancy procedure PRP

-

-

-

  • Passive listening

Yes

Yes

Yes

Protocol is supported PRP

-

-

-

Product functionsSecurity

Protocol is supported SSH

Yes

Yes

Yes

Product functionsTime

Product function SICLOCK support

Yes

Yes

Yes

Protocol is supported

  • NTP

No

No

No

  • SNTP

Yes

Yes

Yes

Standards, specifications, approvals

Standard

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

  • for emitted interference

EN 61000-6-4:2001

EN 61000-6-4 (Class A)

EN 61000-6-4:2001 (Class A)

  • for interference immunity

EN 61000-6-2:2001

EN 61000-6-2

EN 61000-6-4:2001

Verification of suitability

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2, EN 61000-6-4

EN 61000-6-4:2001

  • CE mark

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

No

No

No

  • Railway application in accordance with EN 50124-1

No

No

No

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

No

No

No

  • Bureau Veritas (BV)

No

No

No

  • Det Norske Veritas (DNV)

Yes

Yes

Yes

  • Germanische Lloyd (GL)

Yes

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

No

No

Yes

Marine classification association/ Polski Rejestr Statkow (PRS)

No

No

No


Order No.

6GK5 202-2BB00-2BA3

6GK5 204-0BA00-2BA3

Product type designation

SCALANCE X202-2IRT

SCALANCE X204IRT

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

Interfaces

Number of electrical/optical connections

  • for network components or terminal equipment maximum

4

4

  • as combo port for network components or terminal equipment

-

-

Number of electrical connections

  • for network components and terminal equipment

2

4

  • for alarm contact

1

1

  • for power supply

1

1

  • for redundant power supply

1

1

Design of electrical/optical connections for network components or terminal equipment

Design of electrical connection

  • for network components and terminal equipment

RJ45 port

RJ45 port

  • for signaling contact

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

Number of optical interfaces for optical waveguide at 100 Mbit/s

2

-

Design of optical interface for optical waveguide at 100 Mbit/s

BFOC sockets (multimode up to 5 km)

-

Connectable optical power relative to 1 mW

  • of the transmitter output

-19 ... -14 dB

- -

  • of the receiver input maximum

-

-

Optical sensitivity relative to 1 mW of the receiver input minimum

-34 dB

-

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

-

Range at the optical interface depending on the optical fiber used

0 … 0.05 km

- -

design of the removable storage C-PLUG

Yes

Yes

Inputs/outputs

Operating current of signaling contacts at AC maximum

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

Supply voltage, current consumption, power loss

Type of voltage of supply voltage

DC

DC

Supply voltage external

24 V

24 V

  • minimum

18 V

18 V

  • maximum

32 V

32 V

Product component fusing at power supply input

Yes

Yes

Type of fusing at input for supply voltage

Consumed current maximum

0.3 A

0.2 A

Active power loss at 24 V for DC

6 W

4.8 W

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +60 °C

-40 … +70 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

  • Comment

-

-

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

Protection class IP

IP30

IP30

Design, dimensions and weight

Design

Compact

Compact

Width

60 mm

60 mm

Height

125 mm

125 mm

Depth

124 mm

124 mm

Net weight

0.78 kg

0.78 kg

Type of mounting

  • 35 mm DIN rail mounting

Yes

Yes

  • wall mounting

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Type of mounting

-

-

Product properties, functions, componentsgeneral

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

Product function

  • CLI

Yes

Yes

  • web-based management

Yes

Yes

  • MIB support

Yes

Yes

  • TRAPs via email

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

  • SMTP server

Yes

Yes

  • Port mirroring

No

No

  • for IRT PROFINET IO switch

Yes

Yes

  • PROFINET IO diagnosis

Yes

Yes

  • switch-managed

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

  • HTTP

Yes

Yes

  • HTTPS

Yes

Yes

  • TFTP

Yes

Yes

  • FTP

Yes

Yes

  • BOOTP

No

No

  • SNMP v1

Yes

Yes

  • SNMP v2

Yes

Yes

  • SNMP v3

Yes

Yes

  • DCP

Yes

Yes

  • LLDP

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Product functionsDiagnosis

Product function

  • Port diagnostics

Yes

Yes

  • Statistics Packet Size

Yes

Yes

  • Statistics packet type

Yes

Yes

  • Error statistics

Yes

Yes

Product functionsDHCP

Product function DHCP client

Yes

Yes

Product functionsRedundancy

Product function

  • Ring redundancy

Yes

Yes

  • Redundancy manager

Yes

Yes

  • Standby redundancy

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

  • redundancy procedure PRP

-

-

  • Passive listening

Yes

Yes

Protocol is supported PRP

-

-

Product functionsSecurity

Protocol is supported SSH

Yes

Yes

Product functionsTime

Product function SICLOCK support

Yes

Yes

Protocol is supported

  • NTP

No

No

  • SNTP

Yes

Yes

Standards, specifications, approvals

Standard

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

  • for emitted interference

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

  • for interference immunity

EN 61000-6-4:2001

EN 61000-6-4:2001

Verification of suitability

EN 61000-6-4:2001

EN 61000-6-4:2001

  • CE mark

Yes

Yes

  • C-Tick

Yes

Yes

  • Railway application in accordance with EN 50155

No

No

  • Railway application in accordance with EN 50124-1

No

No

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

  • Bureau Veritas (BV)

No

Yes

  • Det Norske Veritas (DNV)

Yes

Yes

  • Germanische Lloyd (GL)

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Marine classification association/ Polski Rejestr Statkow (PRS)

No

No


Order No.

6GK5 204-0JA00-2BA6

6GK5 202-2JR00-2BA6

6GK5 201-3JR00-2BA6

Product type designation

SCALANCE X204 IRT PRO

SCALANCE X202-2P IRT PRO

SCALANCE X201-3P IRT PRO

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

Interfaces

Number of electrical/optical connections

  • for network components or terminal equipment maximum

4

4

4

  • as combo port for network components or terminal equipment

-

-

-

Number of electrical connections

  • for network components and terminal equipment

4

2

1

  • for alarm contact

1

1

1

  • for power supply

1

1

1

  • for redundant power supply

-

-

-

Design of electrical/optical connections for network components or terminal equipment

Design of electrical connection

  • for network components and terminal equipment

RJ45 push-pull plug PRO

RJ45 push-pull plug PRO

RJ45 push-pull plug PRO

  • for signaling contact

5 pin M12 socket

5 pin M12 socket

5 pin M12 socket

  • for power supply

5-pin push-pull plug PRO socket

5-pin push-pull plug PRO socket

5-pin push-pull plug PRO socket

Number of optical interfaces for optical waveguide at 100 Mbit/s

-

2

3

Design of optical interface for optical waveguide at 100 Mbit/s

-

SC-RJ/POF push-pull plug PRO port

SC-RJ/POF push-pull plug PRO port

Connectable optical power relative to 1 mW

  • of the transmitter output

- -

-8 … -2 dB

-8 … -2 dB

  • of the receiver input maximum

-

-

-

Optical sensitivity relative to 1 mW of the receiver input minimum

-

-25 dB

-25 dB

Attenuation of fiber-optic cable transmission link minimum necessary

-

0 dB

0 dB

Range at the optical interface

  • depending on the optical fiber used

- -

0 … 0.05 km

0 … 0.05 km

design of the removable storage C-PLUG

Yes

Yes

Yes

Inputs/outputs

Operating current of signaling contacts at AC maximum

-

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

Type of voltage of supply voltage

DC

DC

DC

Supply voltage external

24 V

24 V

24 V

  • minimum

18 V

18 V

18 V

  • maximum

32 V

32 V

32 V

Product component fusing at power supply input

Yes

Yes

Yes

Type of fusing at input for supply voltage

Consumed current maximum

0.2 A

0.3 A

0.33 A

Active power loss at 24 V for DC

4.8 W

7.2 W

7.92 W

Permitted ambient conditions

Ambient temperature

  • during operating

-25 … +70 °C

-25 … +60 °C

-25 … +60 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • Comment

-

-

-

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

Protection class IP

IP67

IP67

IP67

Design, dimensions and weight

Design

Compact

Compact

Compact

Width

90 mm

90 mm

90 mm

Height

125 mm

125 mm

125 mm

Depth

124 mm

124 mm

124 mm

net weight

1 kg

1 kg

1 kg

Type of mounting

  • 35 mm DIN rail mounting

Yes

Yes

Yes

  • wall-mounting

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Type of mounting

-

-

-

Product properties, functions, componentsgeneral

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

Product function

  • CLI

Yes

Yes

Yes

  • web-based Management

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

  • Port mirroring

No

No

No

  • for IRT PROFINET IO switch

Yes

Yes

Yes

  • PROFINET IO diagnosis

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

  • BOOTP

No

No

No

  • SNMP v1

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Identification & Maintenance

  • I&M0 - device specific information

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Product functionsDiagnosis

Product function

  • Port diagnostics

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

  • Error Statistics

Yes

Yes

Yes

Product functionsDHCP

Product function DHCP client

Yes

Yes

Yes

Product functionsRedundancy

Product function

  • Ring redundancy

Yes

Yes

Yes

  • Redundancy manager

Yes

Yes

Yes

  • Standby redundancy

Yes

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

Yes

  • redundancy procedure PRP

-

-

-

  • Passive listening

Yes

Yes

Yes

Protocol is supported PRP

-

-

-

Product functionsSecurity

Protocol is supported SSH

Yes

Yes

Yes

Product functionsTime

Product function SICLOCK support

Yes

Yes

Yes

Protocol is supported

  • NTP

No

No

No

  • SNTP

Yes

Yes

Yes

Standards, specifications, approvals

Standard

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

  • for emitted interference

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

  • for interference immunity

EN 61000-6-4:2001

EN 61000-6-4:2001

EN 61000-6-4:2001

Verification of suitability

EN 61000-6-4:2001

EN 61000-6-4:2001

EN 61000-6-4:2001

  • CE-mark

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

No

No

No

  • Railway application in accordance with EN 50124-1

No

No

No

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

No

No

No

  • Bureau Veritas (BV)

Yes

No

No

  • Det Norske Veritas (DNV)

Yes

Yes

No

  • Germanische Lloyd (GL)

Yes

Yes

No

  • Lloyds Register of Shipping (LRS)

Yes

Yes

No

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

No

Marine classification association/ Polski Rejestr Statkow (PRS)

No

No

No
























































Каталог оборудования
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET ECOFAST Введение Industrial Ethernet PROFINET Введение Привода Контроллеры Распределенная периферия Система управления перемещениями SIMOTION Системы ЧПУ SINUMERIK Устройства отображения и контроля Системы Человеко-Машинного Интерфейса Активные сетевые компоненты Промышленные ПК Производственные датчики Пассивные сетевые компоненты Сетевые компоненты для Industrial Ethernet Industrial Ethernet коммутаторы Компактные коммутаторы CSM Неуправляемые коммутаторы SCALANCE X-000 Неуправляемые коммутаторы/конверторы SCALANCE X-100 Управляемые коммутаторы SCALANCE X-200 Управляемые коммутаторы SCALANCE X-200IRT Коммутаторы реального времени SCALANCE X-200IRT Коммутаторы SIPLUS SCALANCE X-200IRT Коммутаторы реального масштаба времени SCALANCE XF-200IRT Управляемые коммутаторы SCALANCE X-300 Управляемые коммутаторы (Уровень 3) SCALANCE X-400 Безопасность передачи данных в промышленных сетях Промышленная мобильная коммуникация Маршрутизаторы Аппаратура управления Датчики Инжиниринговые пакеты Технологические компоненты PROFINET Системный интерфейс к SIMATIC HMI PROFIBUS AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366