Order No. |
6GK5 004-1BD00-1AB2 |
6GK5 004-1BF00-1AB2 |
6GK5 005-0BA00-1AB2 |
6GK5 008-0BA00-1AB2 |
Product type designation |
SCALANCE XB004-1 |
SCALANCE XB004-1LD |
SCALANCE XB005 |
SCALANCE XB008 |
Transmission rate |
||||
Transfer rate 1 |
10 Mbit/s |
10 Mbit/s |
10 Mbit/s |
10 Mbit/s |
Transfer rate 2 |
100 Mbit/s |
100 Mbit/s |
100 Mbit/s |
100 Mbit/s |
Transfer rate 3 |
- |
- |
- |
- |
Interfaces |
||||
Number of electrical/optical connections for network components or terminal equipment maximum |
5 |
5 |
5 |
8 |
Number of electrical connections |
||||
|
4 |
4 |
5 |
8 |
|
- |
- |
- |
- |
|
1 |
1 |
1 |
1 |
Design of electrical connection |
||||
|
RJ45 port |
RJ45 port |
RJ45 port |
RJ45 port |
|
- |
- |
- |
- |
|
3-pole terminal block |
3-pole terminal block |
3-pole terminal block |
3-pole terminal block |
Number of optical interfaces for optical waveguide |
||||
|
1 |
1 |
- |
- |
|
- |
- |
- |
- |
Design of optical interface for optical waveguide |
||||
|
SC port (multimode up to 5 km) |
SC port (singlemode up to 26 km) |
- |
- |
|
- |
- |
- |
- |
Connectable optical power relative to 1 mW |
||||
|
-19 … -14 dB |
-5 … +0 dB |
- - |
- - |
|
-14 dB |
0 dB |
- |
- |
Optical sensitivity relative to 1 mW of the receiver input minimum |
-32 dB |
-34 dB |
- |
- |
Attenuation of fiber-optic cable transmission link minimum necessary |
0 dB |
0 dB |
- |
- |
Range at the optical interface depending on the optical fiber used |
0 … 5 km |
0 … 26 km |
- - |
- - |
Inputs/outputs |
||||
Operating current of signaling contacts at AC maximum |
- |
- |
- |
- |
Operating voltage of signaling contacts at DC rated value |
- |
- |
- |
- |
Operating current of signaling contacts at DC maximum |
- |
- |
- |
- |
Supply voltage, current consumption, power loss |
||||
Type of voltage of supply voltage |
DC |
DC |
DC |
DC |
Supply voltage external |
24 V |
24 V |
24 V |
24 V |
|
19.2 V |
19.2 V |
19.2 V |
19.2 V |
|
28.8 V |
28.8 V |
28.8 V |
28.8 V |
Product component fusing at power supply input |
Yes |
Yes |
Yes |
Yes |
Type of fusing at input for supply voltage |
||||
Consumed current maximum |
0.11 A |
0.1 A |
0.07 A |
0.12 A |
Active power loss at 24 V for DC |
2.64 W |
2.4 W |
1.68 W |
2.88 W |
Permitted ambient conditions |
||||
Ambient temperature |
||||
|
-10 … +60 °C |
-10 … +60 °C |
-10 … +60 °C |
-10 … +60 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
95 % |
95 % |
Protection class IP |
IP20 |
IP20 |
IP20 |
IP20 |
Design, dimensions and weight |
||||
Design |
Box |
Box |
Box |
Box |
Width |
45 mm |
45 mm |
45 mm |
45 mm |
Height |
100 mm |
100 mm |
100 mm |
100 mm |
Depth |
87 mm |
87 mm |
87 mm |
87 mm |
Net weight |
0.165 kg |
0.165 kg |
0.165 kg |
0.18 kg |
Type of mounting |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Type of mounting |
- |
- |
- |
- |
Product properties, functions, componentsgeneral |
||||
Cascading in cases of star structuring |
- |
- |
- |
- |
Standards, specifications, approvals |
||||
Standard |
||||
|
- |
- |
- |
- |
|
- |
- |
- |
- |
|
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
|
- |
- |
- |
- |
|
EN 61000-6-4 (Class A) |
EN 61000-6-4 (Class A) |
EN 61000-6-4 (Class A) |
EN 61000-6-4 (Class A) |
|
EN 61000-6-2 |
EN 61000-6-2 |
EN 61000-6-2 |
EN 61000-6-2 |
Verification of suitability |
EN 61000-6-2, EN 61000-6-4 |
EN 61000-6-2, EN 61000-6-4 |
EN 61000-6-2, EN 61000-6-4 |
EN 61000-6-2, EN 61000-6-4 |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Order No. |
6GK5 004-1GL00-1AB2 |
6GK5 004-1GM00-1AB2 |
6GK5 005-0GA00-1AB2 |
6GK5 008-0GA00-1AB2 |
Product type designation |
SCALANCE XB004-1G |
SCALANCE XB004-1LDG |
SCALANCE XB005G |
SCALANCE XB008G |
Transmission rate |
||||
Transfer rate 1 |
10 Mbit/s |
10 Mbit/s |
10 Mbit/s |
10 Mbit/s |
Transfer rate 2 |
100 Mbit/s |
100 Mbit/s |
100 Mbit/s |
100 Mbit/s |
Transfer rate 3 |
1 000 Mbit/s |
1 000 Mbit/s |
1 000 Mbit/s |
1 000 Mbit/s |
Interfaces |
||||
Number of electrical/optical connections for network components or terminal equipment maximum |
5 |
5 |
5 |
8 |
Number of electrical connections |
||||
|
4 |
4 |
5 |
8 |
|
- |
- |
- |
- |
|
1 |
1 |
1 |
1 |
Design of electrical connection |
||||
|
RJ45 port |
RJ45 port |
RJ45 port |
RJ45 port |
|
- |
- |
- |
- |
|
3-pole terminal block |
3-pole terminal block |
3-pole terminal block |
3-pole terminal block |
Number of optical interfaces for optical waveguide |
||||
|
- |
- |
- |
- |
|
1 |
1 |
- |
- |
Design of optical interface for optical waveguide |
||||
|
- |
- |
- |
- |
|
SC port (multimode up to 0.75 km) |
SC port (singlemode up to 10 km) |
- |
- |
Connectable optical power relative to 1 mW |
||||
|
-9.5 … -4 dB |
-9.5 … -3 dB |
- - |
- - |
|
-3 dB |
-3 dB |
- |
- |
Optical sensitivity relative to 1 mW of the receiver input minimum |
-17 dB |
-21 dB |
- |
- |
Attenuation of fiber-optic cable transmission link minimum necessary |
0 dB |
0 dB |
- |
- |
Range at the optical interface depending on the optical fiber used |
0 … 0.75 km |
0 … 10 km |
- - |
- - |
Inputs/outputs |
||||
Operating current of signaling contacts at AC maximum |
- |
- |
- |
- |
Operating voltage of signaling contacts at DC rated value |
- |
- |
- |
- |
Operating current of signaling contacts at DC maximum |
- |
- |
- |
- |
Supply voltage, current consumption, power loss |
||||
Type of voltage of supply voltage |
DC |
DC |
DC |
DC |
Supply voltage external |
24 V |
24 V |
24 V |
24 V |
|
19.2 V |
19.2 V |
19.2 V |
19.2 V |
|
28.8 V |
28.8 V |
28.8 V |
28.8 V |
Product component fusing at power supply input |
Yes |
Yes |
Yes |
Yes |
Type of fusing at input for supply voltage |
||||
Consumed current maximum |
0.52 A |
0.52 A |
0,44 A |
0.52 A |
Active power loss at 24 V for DC |
12.5 W |
12.5 W |
10,5 W |
12.5 W |
Permitted ambient conditions |
||||
Ambient temperature |
||||
|
-10 … +60 °C |
-10 … +60 °C |
-10 … +60 °C |
-10 … +60 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
95 % |
95 % |
Protection class IP |
IP20 |
IP20 |
IP20 |
IP20 |
Design, dimensions and weight |
||||
Design |
Box |
Box |
Box |
Box |
Width |
45 mm |
45 mm |
45 mm |
45 mm |
Height |
100 mm |
100 mm |
100 mm |
100 mm |
Depth |
87 mm |
87 mm |
87 mm |
87 mm |
Net weight |
0.21 kg |
0.21 kg |
0.22 kg |
0.26 kg |
Type of mounting |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Type of mounting |
- |
- |
- |
- |
Product properties, functions, componentsgeneral |
||||
Cascading in cases of star structuring |
- |
- |
- |
- |
Standards, specifications, approvals |
||||
Standard |
||||
|
- |
- |
- |
- |
|
- |
- |
- |
- |
|
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
|
- |
- |
- |
- |
|
EN 61000-6-4 (Class A) |
EN 61000-6-4 (Class A) |
EN 61000-6-4 (Class B) |
EN 61000-6-4 (Class B) |
|
EN 61000-6-2 |
EN 61000-6-2 |
EN 61000-6-2 |
EN 61000-6-2 |
Verification of suitability |
EN 61000-6-2, EN 61000-6-4 |
EN 61000-6-2, EN 61000-6-4 |
EN 61000-6-2, EN 61000-6-4 |
EN 61000-6-2, EN 61000-6-4 |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |