Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Order No. |
6GK5 788-1AA60-2AA0 |
6GK5 788-2AA60-2AA0 |
6GK5 788-1AA60-6AA0 |
6GK5 788-2AA60-6AA0 |
6GK5 788-1AA60-2AB0 1) |
6GK5 788-2AA60-2AB0 1) |
6GK5 788-1AA60-6AB0 1) |
6GK5 788-2AA60-6AB0 1) |
|
Product type designation |
SCALANCE W788-1PRO |
SCALANCE W788-2PRO |
SCALANCE W788-1RR |
SCALANCE W788-2RR |
Transmission rate |
||||
Transmission rate |
||||
|
54 Mbit/s |
54 Mbit/s |
54 Mbit/s |
54 Mbit/s |
|
10 … 100 Mbit/s |
10 … 100 Mbit/s |
10 … 100 Mbit/s |
10 … 100 Mbit/s |
|
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Interfaces |
||||
Number of electrical connections |
||||
|
1 |
1 |
1 |
1 |
|
1 |
1 |
1 |
1 |
|
1 |
1 |
1 |
1 |
Design of electrical connection |
||||
|
Hybrid socket, RJ45 integrated |
Hybrid socket, RJ45 integrated |
Hybrid socket, RJ45 integrated |
Hybrid socket, RJ45 integrated |
|
M12 interface (4-pole, A-coded), hybrid socket, PoE |
M12 interface (4-pole, A-coded), hybrid socket, PoE |
M12 interface (4-pole, A-coded), hybrid socket, PoE |
M12 interface (4-pole, A-coded), hybrid socket, PoE |
design of the removable storage C-PLUG |
Yes |
Yes |
Yes |
Yes |
Interfaceswireless |
||||
Number of radio cards permanently installed |
1 |
2 |
1 |
2 |
Number of electrical connections for external antenna(s) |
2 |
4 |
2 |
4 |
Design of the electrical connection for external antenna(s) |
R-SMA female (socket) |
R-SMA female (socket) |
R-SMA female (socket) |
R-SMA female (socket) |
Supply voltage, current consumption, power loss |
||||
Type of voltage of supply voltage |
DC |
DC |
DC |
DC |
Supply voltage |
||||
|
24 V |
24 V |
24 V |
24 V |
|
48 V |
48 V |
48 V |
48 V |
|
24 V |
24 V |
24 V |
24 V |
|
48 V |
48 V |
48 V |
48 V |
|
48 V |
48 V |
48 V |
48 V |
Current consumed |
||||
|
0.25 A |
0.295 A |
0.25 A |
0.295 A |
|
0.125 A |
0.15 A |
0.125 A |
0.15 A |
|
0.125 A |
0.15 A |
0.125 A |
0.15 A |
Effective power loss |
||||
|
7 W |
7 W |
7 W |
9 W |
|
7 W |
7 W |
7 W |
9 W |
|
7 W |
7 W |
7 W |
9 W |
Permitted ambient conditions |
||||
Ambient temperature |
||||
|
-20 … +60 °C |
-20 … +60 °C |
-20 … +60 °C |
-20 … +60 °C |
|
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
|
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
Relative humidity at 25 °C without condensation during operating maximum |
100 % |
100 % |
100 % |
100 % |
Protection class IP |
IP65 |
IP65 |
IP65 |
IP65 |
Ambient condition for (standard) operation mode |
When used under hazardous conditions (Zone 2), the SCALANCE W788-xPRO/RR or W74x-1PRO/RR product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529. |
When used under hazardous conditions (Zone 2), the SCALANCE W788-xPRO/RR or W74x-1PRO/RR product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529. |
When used under hazardous conditions (Zone 2), the SCALANCE W788-xPRO/RR or W74x-1PRO/RR product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529. |
When used under hazardous conditions (Zone 2), the SCALANCE W788-xPRO/RR or W74x-1PRO/RR product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529. |
Design, dimensions and weight |
||||
Width of enclosure without antenna |
125 mm |
125 mm |
125 mm |
125 mm |
Height of enclosure without antenna |
88 mm |
88 mm |
88 mm |
88 mm |
Depth of enclosure without antenna |
108 mm |
108 mm |
108 mm |
108 mm |
Net weight |
1.05 kg |
1.05 kg |
1.05 kg |
1.05 kg |
Type of mounting |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Wireless frequencies |
||||
Radio frequency |
||||
|
2.41 … 2.48 GHz |
2.41 … 2.48 GHz |
2.41 … 2.48 GHz |
2.41 … 2.48 GHz |
|
4.9 … 5.8 GHz |
4.9 … 5.8 GHz |
4.9 … 5.8 GHz |
4.9 … 5.8 GHz |
Product properties, functions, componentsgeneral |
||||
Number of SSIDs |
8 |
16 |
8 |
16 |
Product function |
||||
|
No |
No |
Yes |
Yes |
|
No |
No |
Yes |
Yes |
|
No |
No |
Yes |
Yes |
|
No |
No |
No |
Yes |
Number of iPCF-capable radio modules |
0 |
0 |
1 |
1 |
Product functionsmanagement, configuration |
||||
Number of manageable IP addresses in client |
8 |
8 |
8 |
8 |
Product function |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
|
No |
No |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Protocol is supported |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Identification & maintenance |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Product functionsDiagnosis |
||||
Product function |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Product functionsVLAN |
||||
Product function function VLAN with IWLAN |
Yes |
Yes |
Yes |
Yes |
Product functionsDHCP |
||||
Product function DHCP client |
Yes |
Yes |
Yes |
Yes |
Product functionsRedundancy |
||||
Protocol is supported STP/RSTP |
Yes |
Yes |
Yes |
Yes |
Product functionsSecurity |
||||
Product function |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Protocol is supported SSH |
Yes |
Yes |
Yes |
Yes |
Product functionsTime |
||||
Protocol is supported SNTP |
Yes |
Yes |
Yes |
Yes |
Standards, specifications, approvals |
||||
Standard |
||||
|
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
|
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
|
UL 60950-1 CSA C22.2 No. 60950-1 |
UL 60950-1 CSA C22.2 No. 60950-1 |
UL 60950-1 CSA C22.2 No. 60950-1 |
UL 60950-1 CSA C22.2 No. 60950-1 |
|
ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 |
ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 |
ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 |
ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 |
Certificate of suitability |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Standard for wireless communication |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
Wireless approval |
||||
Marine classification association |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Marine classification association / Polski Rejestr Statkow (PRS) |
Yes |
Yes |
Yes |
Yes |
Accessories |
||||
Accessories |
2 antennas, hybrid connector included in scope of delivery |
2 antennas, hybrid connector included in scope of delivery |
2 antennas, hybrid connector included in scope of delivery |
2 antennas, hybrid connector included in scope of delivery |
1) Wireless approval in the USA
Order No. |
6GK5 786-1BA60-2AA0 |
6GK5 786-1AA60-2AA0 |
6GK5 786-1BB60-2AA0 |
6GK5 786-1AB60-2AA0 |
6GK5 786-1BA60-2AB0 1) |
6GK5 786-1AA60-2AB0 1) |
6GK5 786-1BB60-2AB0 1) |
6GK5 786-1AB60-2AB0 1) |
|
Product type designation |
SCALANCE W786-1PRO |
SCALANCE W786-1PRO |
SCALANCE W786-1PRO |
SCALANCE W786-1PRO |
Transmission rate |
||||
Transmission rate |
||||
|
54 Mbit/s |
54 Mbit/s |
54 Mbit/s |
54 Mbit/s |
|
10 … 100 Mbit/s |
10 … 100 Mbit/s |
10 … 100 Mbit/s |
10 … 100 Mbit/s |
|
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Interfaces |
||||
Number of electrical connections |
||||
|
1 |
1 |
- |
- |
|
1 |
1 |
1 |
1 |
|
1 |
1 |
1 |
1 |
Design of electrical connection |
||||
|
RJ45 socket |
RJ45 socket |
- |
- |
|
2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
Number of optical interfaces for optical waveguide at 100 Mbit/s |
- |
- |
1 |
1 |
Design of optical interface for optical waveguide at 100 Mbit/s |
- |
- |
Duplex multimode FOC (ST) |
Duplex multimode FOC (ST) |
design of the removable storage C-PLUG |
Yes |
Yes |
Yes |
Yes |
Interfaceswireless |
||||
Number of radio cards permanently installed |
1 |
1 |
1 |
1 |
Number of internal antennas |
2 |
- |
2 |
- |
Number of electrical connections for external antenna(s) |
- |
2 |
- |
2 |
Design of the electrical connection for external antenna(s) |
- |
R-SMA female (socket) |
- |
R-SMA female (socket) |
Supply voltage, current consumption, power loss |
||||
Type of voltage of supply voltage |
DC |
DC |
DC |
DC |
Supply voltage |
||||
|
48 V |
48 V |
48 V |
48 V |
|
- |
- |
- |
- |
|
48 V |
48 V |
48 V |
48 V |
|
||||
|
100 … 240 V |
100 … 240 V |
100 … 240 V |
100 … 240 V |
|
12 … 24 V |
12 … 24 V |
12 … 24 V |
12 … 24 V |
Current consumed |
||||
|
0.28 A |
0.28 A |
0.34 A |
0.34 A |
|
0.14 A |
0.14 A |
0.17 A |
0.17 A |
|
0.03 A |
0.03 A |
0.04 A |
0.04 A |
|
0.14 A |
0.14 A |
0.34 A |
0.34 A |
Effective power loss |
||||
|
6.5 W |
6.5 W |
8 W |
8 W |
|
6.5 W |
6.5 W |
8 W |
8 W |
|
6.5 W |
6.5 W |
8 W |
8 W |
|
6.5 W |
6.5 W |
8 W |
8 W |
Permitted ambient conditions |
||||
Ambient temperature |
||||
|
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
|
-40 … +85 °C |
-40 … +85 °C |
-40 … +85 °C |
-40 … +85 °C |
|
-40 … +85 °C |
-40 … +85 °C |
-40 … +85 °C |
-40 … +85 °C |
Relative humidity at 25 °C without condensation during operating maximum |
100 % |
100 % |
100 % |
100 % |
Protection class IP |
IP65 |
IP65 |
IP65 |
IP65 |
Ambient condition for (standard) operation mode |
When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
Design, dimensions and weight |
||||
Width of enclosure without antenna |
251 mm |
251 mm |
251 mm |
251 mm |
Height of enclosure without antenna |
251 mm |
251 mm |
251 mm |
251 mm |
Depth of enclosure without antenna |
72 mm |
72 mm |
72 mm |
72 mm |
Net weight |
2.24 kg |
2.24 kg |
2.24 kg |
2.24 kg |
Type of mounting |
||||
|
- |
- |
- |
- |
|
Yes |
Yes |
Yes |
Yes |
Type of mounting |
For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
Wireless frequencies |
||||
Radio frequency |
||||
|
2.41 … 2.48 GHz |
2.41 … 2.48 GHz |
2.41 … 2.48 GHz |
2.41 … 2.48 GHz |
|
4.9 … 5.8 GHz |
4.9 … 5.8 GHz |
4.9 … 5.8 GHz |
4.9 … 5.8 GHz |
Product properties, functions, componentsgeneral |
||||
Number of SSIDs |
8 |
8 |
8 |
8 |
Product function |
||||
|
No |
No |
No |
No |
|
No |
No |
No |
No |
|
No |
No |
No |
No |
|
No |
No |
No |
No |
Number of iPCF-capable radio modules |
0 |
0 |
0 |
0 |
Product functionsmanagement, configuration |
||||
Number of manageable IP addresses in client |
8 |
8 |
8 |
8 |
Product function |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
|
No |
No |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Protocol is supported |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Identification & maintenance |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Product functionsDiagnosis |
||||
Product function |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Product functionsVLAN |
||||
Product function function VLAN with IWLAN |
Yes |
Yes |
Yes |
Yes |
Product functionsDHCP |
||||
Product function DHCP client |
Yes |
Yes |
Yes |
Yes |
Product functionsRedundancy |
||||
Protocol is supported STP/RSTP |
Yes |
Yes |
Yes |
Yes |
Product functionsSecurity |
||||
Product function |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Protocol is supported SSH |
Yes |
Yes |
Yes |
Yes |
Product functionsTime |
||||
Protocol is supported SNTP |
Yes |
Yes |
Yes |
Yes |
Standards, specifications, approvals |
||||
Standard |
||||
|
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
|
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
|
UL 60950-1 CSA C22.2 No. 60950-1 |
UL 60950-1 CSA C22.2 No. 60950-1 |
UL 60950-1 CSA C22.2 No. 60950-1 |
UL 60950-1 CSA C22.2 No. 60950-1 |
|
UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
Certificate of suitability |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
|
No |
No |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Standard for wireless communication |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
Wireless approval |
You can find the current list of countries at: www.siemens.com/simatic-net/ik-info |
|||
Marine classification association |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Marine classification association / Polski Rejestr Statkow (PRS) |
No |
No |
No |
No |
Accessories |
||||
Accessories |
48 V DC screw terminal included in scope of delivery |
48 V DC screw terminal included in scope of delivery |
48 V DC screw terminal included in scope of delivery |
48 V DC screw terminal included in scope of delivery |
1) Wireless approval in the USA
Order No. |
6GK5 786-2BA60-2AA0 |
6GK5 786-2AA60-2AA0 |
6GK5 786-2BB60-2AA0 |
6GK5 786-2AB60-2AA0 |
6GK5 786-2BA60-2AB0 1) |
6GK5 786-2AA60-2AB0 1) |
6GK5 786-2BB60-2AB0 1) |
6GK5 786-2AB60-2AB0 1) |
|
Product type designation |
SCALANCE W786-2PRO |
SCALANCE W786-2PRO |
SCALANCE W786-2PRO |
SCALANCE W786-2PRO |
Transmission rate |
||||
Transmission rate |
||||
|
54 Mbit/s |
54 Mbit/s |
54 Mbit/s |
54 Mbit/s |
|
10 … 100 Mbit/s |
10 … 100 Mbit/s |
10 … 100 Mbit/s |
10 … 100 Mbit/s |
|
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Interfaces |
||||
Number of electrical connections |
||||
|
1 |
1 |
- |
- |
|
1 |
1 |
1 |
1 |
|
1 |
1 |
1 |
1 |
Design of electrical connection |
||||
|
RJ45 socket |
RJ45 socket |
- |
- |
|
2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
Number of optical interfaces for optical waveguide at 100 Mbit/s |
- |
- |
1 |
1 |
Design of optical interface for optical waveguide at 100 Mbit/s |
- |
- |
Duplex multimode FOC (ST) |
Duplex multimode FOC (ST) |
design of the removable storage C-PLUG |
Yes |
Yes |
Yes |
Yes |
Interfaceswireless |
||||
Number of radio cards permanently installed |
2 |
2 |
2 |
2 |
Number of internal antennas |
4 |
- |
4 |
- |
Number of electrical connections for external antenna(s) |
- |
4 |
- |
4 |
Design of the electrical connection for external antenna(s) |
- |
R-SMA female (socket) |
- |
R-SMA female (socket) |
Supply voltage, current consumption, power loss |
||||
Type of voltage of supply voltage |
DC |
DC |
DC |
DC |
Supply voltage |
||||
|
48 V |
48 V |
48 V |
48 V |
|
- |
- |
- |
- |
|
48 V |
48 V |
48 V |
48 V |
|
||||
|
100 … 240 V |
100 … 240 V |
100 … 240 V |
100 … 240 V |
|
12 … 24 V |
12 … 24 V |
12 … 24 V |
12 … 24 V |
Current consumed |
||||
|
0.34 A |
0.34 A |
0.4 A |
0.4 A |
|
0.17 A |
0.17 A |
0.2 A |
0.2 A |
|
0.04 A |
0.04 A |
0.05 A |
0.05 A |
|
0.34 A |
0.34 A |
0.2 A |
0.2 A |
Effective power loss |
||||
|
8 W |
8 W |
9.5 W |
9.5 W |
|
8 W |
8 W |
9.5 W |
9.5 W |
|
8 W |
8 W |
9.5 W |
9.5 W |
|
8 W |
8 W |
9.5 W |
9.5 W |
Permitted ambient conditions |
||||
Ambient temperature |
||||
|
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
|
-40 … +85 °C |
-40 … +85 °C |
-40 … +85 °C |
-40 … +85 °C |
|
-40 … +85 °C |
-40 … +85 °C |
-40 … +85 °C |
-40 … +85 °C |
Relative humidity at 25 °C without condensation during operating maximum |
100 % |
100 % |
100 % |
100 % |
Protection class IP |
IP65 |
IP65 |
IP65 |
IP65 |
Ambient condition for (standard) operation mode |
When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
Design, dimensions and weight |
||||
Width of enclosure without antenna |
251 mm |
251 mm |
251 mm |
251 mm |
Height of enclosure without antenna |
251 mm |
251 mm |
251 mm |
251 mm |
Depth of enclosure without antenna |
72 mm |
72 mm |
72 mm |
72 mm |
Net weight |
2.24 kg |
2.24 kg |
2.24 kg |
2.24 kg |
Type of mounting |
||||
|
- |
- |
- |
- |
|
Yes |
Yes |
Yes |
Yes |
Type of mounting |
For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
Wireless frequencies |
||||
Radio frequency |
||||
|
2.41 … 2.48 GHz |
2.41 … 2.48 GHz |
2.41 … 2.48 GHz |
2.41 … 2.48 GHz |
|
4.9 … 5.8 GHz |
4.9 … 5.8 GHz |
4.9 … 5.8 GHz |
4.9 … 5.8 GHz |
Product properties, functions, componentsgeneral |
||||
Number of SSIDs |
16 |
16 |
16 |
16 |
Product function |
||||
|
No |
No |
No |
No |
|
No |
No |
No |
No |
|
No |
No |
No |
No |
|
No |
No |
No |
No |
Number of iPCF-capable radio modules |
0 |
0 |
0 |
0 |
Product functionsmanagement, configuration |
||||
Number of manageable IP addresses in client |
8 |
8 |
8 |
8 |
Product function |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
|
No |
No |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Protocol is supported |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Identification & maintenance |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Product functionsDiagnosis |
||||
Product function |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Product functionsVLAN |
||||
Product function function VLAN with IWLAN |
Yes |
Yes |
Yes |
Yes |
Product functionsDHCP |
||||
Product function DHCP client |
Yes |
Yes |
Yes |
Yes |
Product functionsRedundancy |
||||
Protocol is supported STP/RSTP |
Yes |
Yes |
Yes |
Yes |
Product functionsSecurity |
||||
Product function |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Protocol is supported SSH |
Yes |
Yes |
Yes |
Yes |
Product functionsTime |
||||
Protocol is supported SNTP |
Yes |
Yes |
Yes |
Yes |
Standards, specifications, approvals |
||||
Standard |
||||
|
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
|
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
|
UL 60950-1 CSA C22.2 No. 60950-1 |
UL 60950-1 CSA C22.2 No. 60950-1 |
UL 60950-1 CSA C22.2 No. 60950-1 |
UL 60950-1 CSA C22.2 No. 60950-1 |
|
UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
Certificate of suitability |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
|
No |
No |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Standard for wireless communication |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
Wireless approval |
||||
Marine classification association |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Marine classification association/ Polski Rejestr Statkow (PRS) |
No |
No |
No |
No |
Accessories |
||||
Accessories |
48 V DC screw terminal included in scope of delivery |
48 V DC screw terminal included in scope of delivery |
48 V DC screw terminal included in scope of delivery |
48 V DC screw terminal included in scope of delivery |
1) Wireless approval in the USA
Order No. |
6GK5 786-3AA60-2AA0 |
6GK5 786-3AB60-2AA0 |
6GK5 786-2BA60-6AA0 |
6GK5 786-2AA60-6AA0 |
6GK5 786-3AA60-2AB0 1) |
6GK5 786-3AB60-2AB0 1) |
6GK5 786-2BA60-6AB0 1) |
6GK5 786-2AA60-6AB0 1) |
|
Product type designation |
SCALANCE W786-3PRO |
SCALANCE W786-3PRO |
SCALANCE W786-2RR |
SCALANCE W786-2RR |
Transmission rate |
||||
Transmission rate |
||||
|
54 Mbit/s |
54 Mbit/s |
54 Mbit/s |
54 Mbit/s |
|
10 … 100 Mbit/s |
10 … 100 Mbit/s |
10 … 100 Mbit/s |
10 … 100 Mbit/s |
|
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Interfaces |
||||
Number of electrical connections |
||||
|
1 |
- |
1 |
1 |
|
1 |
1 |
1 |
1 |
|
1 |
1 |
1 |
1 |
Design of electrical connection |
||||
|
RJ45 socket |
- |
RJ45 socket |
RJ45 socket |
|
2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
Number of optical interfaces for optical waveguide at 100 Mbit/s |
- |
1 |
- |
- |
Design of optical interface for optical waveguide at 100 Mbit/s |
- |
Duplex multimode FOC (ST) |
- |
- |
design of the removable storage C-PLUG |
Yes |
Yes |
Yes |
Yes |
Interfaceswireless |
||||
Number of radio cards permanently installed |
3 |
3 |
2 |
2 |
Number of internal antennas |
- |
- |
4 |
- |
Number of electrical connections for external antenna(s) |
6 |
6 |
- |
4 |
Design of the electrical connection for external antenna(s) |
R-SMA female (socket) |
R-SMA female (socket) |
- |
R-SMA female (socket) |
Supply voltage, current consumption, power loss |
||||
Type of voltage of supply voltage |
DC |
DC |
DC |
DC |
Supply voltage |
||||
|
48 V |
48 V |
48 V |
48 V |
|
- |
- |
- |
- |
|
48 V |
48 V |
48 V |
48 V |
|
||||
|
100 … 240 V |
100 … 240 V |
100 … 240 V |
100 … 240 V |
|
12 … 24 V |
12 … 24 V |
12 … 24 V |
12 … 24 V |
Current consumed |
||||
|
0.4 A |
0.46 A |
0.34 A |
0.34 A |
|
0.2 A |
0.23 A |
0.17 A |
0.17 A |
|
0.05 A |
0.05 A |
0.04 A |
0.04 A |
|
0.2 A |
0.23 A |
0.34 A |
0.34 A |
Effective power loss |
||||
|
9.5 W |
11 W |
8 W |
8 W |
|
9.5 W |
11 W |
8 W |
8 W |
|
9.5 W |
11 W |
8 W |
8 W |
|
9.5 W |
11 W |
8 W |
8 W |
Permitted ambient conditions |
||||
Ambient temperature |
||||
|
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
|
-40 … +85 °C |
-40 … +85 °C |
-40 … +85 °C |
-40 … +85 °C |
|
-40 … +85 °C |
-40 … +85 °C |
-40 … +85 °C |
-40 … +85 °C |
Relative humidity at 25 °C without condensation during operating maximum |
100 % |
100 % |
100 % |
100 % |
Protection class IP |
IP65 |
IP65 |
IP65 |
IP65 |
Ambient condition for (standard) operation mode |
When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
Design, dimensions and weight |
||||
Width of enclosure without antenna |
251 mm |
251 mm |
251 mm |
251 mm |
Height of enclosure without antenna |
251 mm |
251 mm |
251 mm |
251 mm |
Depth of enclosure without antenna |
72 mm |
72 mm |
72 mm |
72 mm |
Net weight |
2.24 kg |
2.24 kg |
2.24 kg |
2.24 kg |
Type of mounting |
||||
|
- |
- |
- |
- |
|
Yes |
Yes |
Yes |
Yes |
Type of mounting |
For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
Wireless frequencies |
||||
Radio frequency |
||||
|
2.41 … 2.48 GHz |
2.41 … 2.48 GHz |
2.41 … 2.48 GHz |
2.41 … 2.48 GHz |
|
4.9 … 5.8 GHz |
4.9 … 5.8 GHz |
4.9 … 5.8 GHz |
4.9 … 5.8 GHz |
Product properties, functions, componentsgeneral |
||||
Number of SSIDs |
24 |
24 |
16 |
16 |
Product function |
||||
|
No |
No |
Yes |
Yes |
|
No |
No |
Yes |
Yes |
|
No |
No |
Yes |
Yes |
|
No |
No |
Yes |
Yes |
Number of iPCF-capable radio modules |
0 |
0 |
1 |
1 |
Product functionsmanagement, configuration |
||||
Number of manageable IP addresses in client |
8 |
8 |
8 |
8 |
Product function |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
|
No |
No |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Protocol is supported |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Identification & maintenance |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Product functionsDiagnosis |
||||
Product function |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Product functionsVLAN |
||||
Product function function VLAN with IWLAN |
Yes |
Yes |
Yes |
Yes |
Product functionsDHCP |
||||
Product function DHCP client |
Yes |
Yes |
Yes |
Yes |
Product functionsRedundancy |
||||
Protocol is supported STP/RSTP |
Yes |
Yes |
Yes |
Yes |
Product functionsSecurity |
||||
Product function |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Protocol is supported SSH |
Yes |
Yes |
Yes |
Yes |
Product functionsTime |
||||
Protocol is supported SNTP |
Yes |
Yes |
Yes |
Yes |
Standards, specifications, approvals |
||||
Standard |
||||
|
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
|
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
|
UL 60950-1 CSA C22.2 No. 60950-1 |
UL 60950-1 CSA C22.2 No. 60950-1 |
UL 60950-1 CSA C22.2 No. 60950-1 |
UL 60950-1 CSA C22.2 No. 60950-1 |
|
UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
Certificate of suitability |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
|
No |
No |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Standard for wireless communication |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
Wireless approval |
||||
Marine classification association |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
No |
No |
No |
No |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Marine classification association/ Polski Rejestr Statkow (PRS) |
No |
No |
No |
No |
Accessories |
||||
Accessories |
48 V DC screw terminal included in scope of delivery |
48 V DC screw terminal included in scope of delivery |
48 V DC screw terminal included in scope of delivery |
48 V DC screw terminal included in scope of delivery |
1) Wireless approval in the USA
Order No. |
6GK5 784-1AA30-2AA0 |
6GK5 784-1AA30-6AA0 |
6GK5 784-1AA30-2AB0 1) |
6GK5 784-1AA30-6AB0 1) |
|
Product type designation |
SCALANCE W784-1 |
SCALANCE W784-1RR |
Transmission rate |
||
Transmission rate |
||
|
54 Mbit/s |
54 Mbit/s |
|
10 … 100 Mbit/s |
10 … 100 Mbit/s |
|
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Interfaces |
||
Number of electrical connections |
||
|
1 |
1 |
|
1 |
1 |
|
1 |
1 |
Design of electrical connection |
||
|
RJ45 socket |
RJ45 socket |
|
4-pole screw terminal, PoE |
4-pole screw terminal, PoE |
design of the removable storage C-PLUG |
Yes |
Yes |
Interfaceswireless |
||
Number of radio cards permanently installed |
1 |
1 |
Number of electrical connections for external antenna(s) |
2 |
2 |
Design of the electrical connection for external antenna(s) |
R-SMA female (socket) |
R-SMA female (socket) |
Supply voltage, current consumption, power loss |
||
Type of voltage of supply voltage |
DC |
DC |
Supply voltage |
||
|
24 V |
24 V |
|
48 V |
48 V |
|
48 V |
48 V |
Current consumed |
||
|
0.23 A |
0.23 A |
|
0.12 A |
0.12 A |
|
0.12 A |
0.12 A |
Effective power loss |
||
|
6 W |
6 W |
|
6 W |
6 W |
|
6 W |
6 W |
Permitted ambient conditions |
||
Ambient temperature |
||
|
-20 … +60 °C |
-20 … +60 °C |
|
-40 … +70 °C |
-40 … +70 °C |
|
-40 … +70 °C |
-40 … +70 °C |
Relative humidity at 25 °C without condensation during operating maximum |
90 % |
90 % |
Protection class IP |
IP30 |
IP30 |
Ambient condition for (standard) operation mode |
- |
- |
Design, dimensions and weight |
||
Width of enclosure without antenna |
100 mm |
100 mm |
Height of enclosure without antenna |
205 mm |
205 mm |
Depth of enclosure without antenna |
20 mm |
20 mm |
Net weight |
0.29 kg |
0.29 kg |
Type of mounting |
||
|
- |
- |
|
Yes |
Yes |
Type of mounting |
For mounting on 35 mm DIN and S7-300 mounting rail, an additional adapter plate is required |
For mounting on 35 mm DIN and S7-300 mounting rail, an additional adapter plate is required |
Wireless frequencies |
||
Radio frequency |
||
|
2.41 … 2.48 GHz |
2.41 … 2.48 GHz |
|
4.9 … 5.8 GHz |
4.9 … 5.8 GHz |
Product properties, functions, componentsgeneral |
||
Number of SSIDs |
8 |
8 |
Product function |
||
|
No |
Yes |
|
No |
Yes |
|
No |
Yes |
|
No |
No |
Number of iPCF-capable radio modules |
0 |
1 |
Product functionsmanagement, configuration |
||
Number of manageable IP addresses in client |
8 |
8 |
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
No |
No |
|
No |
No |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Protocol is supported |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Identification & maintenance |
||
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsDiagnosis |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsVLAN |
||
Product function function VLAN with IWLAN |
Yes |
Yes |
Product functionsDHCP |
||
Product function DHCP client |
Yes |
Yes |
Product functionsRedundancy |
||
Protocol is supported STP/RSTP |
Yes |
Yes |
Product functionsSecurity |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Protocol is supported SSH |
Yes |
Yes |
Product functionsTime |
||
Protocol is supported SNTP |
Yes |
Yes |
Standards, specifications, approvals |
||
Standard |
||
|
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
|
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X (only approved in combination with an enclosure with degree of protection of at least IP 54) |
EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X (only approved in combination with an enclosure with degree of protection of at least IP 54) |
|
UL 60950-1 CSA C22.2 No. 60950-1 |
UL 60950-1 CSA C22.2 No. 60950-1 |
|
ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 (only approved in combination with an enclosure with degree of protection of at least IP 54) |
ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 (only approved in combination with an enclosure with degree of protection of at least IP 54) |
Certificate of suitability |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
No |
No |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Standard for wireless communication |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
No |
No |
Wireless approval |
||
Marine classification association |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
No |
No |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Marine classification association/ Polski Rejestr Statkow (PRS) |
No |
No |
Accessories |
||
Accessories |
24 V DC screw terminal included in scope of delivery |
24 V DC screw terminal included in scope of delivery |
1) Wireless approval in the USA